Ultrasonography.  2020 Jan;39(1):52-59. 10.14366/usg.19013.

Assessment of liver fibrosis using 2-dimensional shear wave elastography: a prospective study of intra- and inter-observer repeatability and comparison with point shear wave elastography

Affiliations
  • 1Department of Radiology, Seoul National University Hospital, Seoul, Korea
  • 2Department of Radiology, Seoul National University College of Medicine, Seoul, Korea
  • 3Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea

Abstract

Purpose
The purpose of this study was to prospectively investigate the intra- and interobserver repeatability of a new 2-dimensional (2D) shear wave elastography (SWE) technique (S-Shearwave Imaging) for assessing liver fibrosis in chronic liver disease patients, and to compare liver stiffness measurements (LSMs) made using 2D-SWE with those made using point SWE (pSWE).
Methods
This prospective study received institutional review board approval and informed consent was obtained from all patients. Fifty-three chronic liver disease patients were randomly allocated to group 1 (for intra-observer repeatability [n=33]) or group 2 (for inter-observer repeatability [n=20]). In group 1, two 2D-SWE sessions and one pSWE sessions were performed by one radiologist. In group 2, one 2D-SWE session and one pSWE session were performed by the aforementioned radiologist, and a second 2D-SWE session was performed by another radiologist. The intraclass correlation coefficient (ICC) was used to assess intra- and interobserver reliability. LSMs obtained using 2D-SWE and pSWE were compared and correlated using the paired t test and Pearson correlation coefficient, respectively.
Results
LSMs made using 2D-SWE demonstrated excellent intra- and inter-observer repeatability (ICC, 0.997 [95% confidence interval, 0.994 to 0.999]) and 0.995 [0.988 to 0.998], respectively). LSMs made using 2D-SWE were significantly different from those made using pSWE (2.1±0.6 m/sec vs. 1.9±0.6 m/sec, P<0.001), although a significant correlation existed between the 2D-SWE and pSWE LSMs (rho=0.836, P<0.001).
Conclusion
S-Shearwave Imaging demonstrated excellent intra- and inter-observer repeatability, and a strong correlation with pSWE measurements of liver stiffness. However, because of the significant difference between LSMs obtained using 2D-SWE and pSWE, these methods should not be used interchangeably.

Keyword

Ultrasonography; Elasticity imaging techniques; Liver cirrhosis
Full Text Links
  • USG
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr