Korean J Anesthesiol.  2019 Dec;72(6):548-557. 10.4097/kja.19318.

Awake supraglottic airway guided flexible bronchoscopic intubation in patients with anticipated difficult airways: a case series and narrative review

Affiliations
  • 1Department of Anesthesiology, Singapore General Hospital, Singapore, Singapore. lim.wan.yen@singhealth.com.sg

Abstract

Awake intubation is indicated in difficult airways if attempts at securing the airway after induction of general anesthesia may lead to harm due to potential difficulties or failure in those attempts. Conventional awake flexible bronchoscopic intubation is performed via the nasal, or less commonly, oral route. Awake oral flexible bronchoscopic intubation (FBI) via a supraglottic airway device (SAD) is a less common technique; we refer to this as "˜supraglottic airway guided' FBI (SAGFBI). We describe ten cases with anticipated difficult airways in which awake SAGFBI was performed. After sedation and adequate airway topicalization, an Ambu Auragainâ„¢ SAD was inserted. A flexible bronchoscope, preloaded with a tracheal tube, was then inserted through the SAD. Finally, the tracheal tube was railroaded over the bronchoscope, through the SAD and into the trachea. The bronchoscope and the SAD were carefully removed, whilst keeping the tracheal tube in-situ. The technique was successful and well tolerated by all patients, and associated complications were rare. It also offered the advantages of performing an "˜awake test insertion' of the SAD, an "˜awake look' at the periglottic region, and an "˜awake test ventilation.' In certain patients, awake SAGFBI offers advantages over conventional awake FBI or awake videolaryngoscopy. More research is required to evaluate its success and failure rates, and identify associated complications. Its place in difficult airway algorithms may then be further established.

Keyword

Airway; Awake intubation; Fiberoptic intubation; Intratracheal; Intubation; Laryngoscopy; Ventilation; Videolaryngoscopy

MeSH Terms

Anesthesia, General
Bronchoscopes
Humans
Intubation*
Laryngoscopy
Railroads
Trachea
Ventilation

Cited by  3 articles

Supraglottic airway devices: more good than bad
Hee-Pyoung Park
Korean J Anesthesiol. 2019;72(6):525-526.    doi: 10.4097/kja.19417.

Awake supraglottic airway guided flexible bronchoscopic intubation
Anju Romina Bhalotra
Korean J Anesthesiol. 2020;73(2):173-174.    doi: 10.4097/kja.20013.

Awake supraglottic airway guided intubation: for the patient, by the patient
Nishant Sahay, Rajnish Kumar, Shagufta Naaz, Vivekanand
Korean J Anesthesiol. 2020;73(3):262-263.    doi: 10.4097/kja.20055.