Korean J Blood Transfus.  2019 Aug;30(2):148-155. 10.17945/kjbt.2019.30.2.148.

Risk Factors for Adverse Events of Therapeutic Plasma Exchange Assessed in a Single Center Study

Affiliations
  • 1Department of Laboratory Medicine, Daegu Catholic University School of Medicine, Daegu, Korea. ajinlee@cu.ac.kr

Abstract

BACKGROUND
Therapeutic plasma exchange (TPE) is used to remove pathologic substances involved in various disease etiologies. The use of TPE is increasing steadily in a variety of disease. This study analyzed the incidence, type and severity of adverse events (AE) according to the initial TPE of each patient in a single center. The risk factors for AE of TPE were also elucidated.
METHODS
The medical and laboratory records of patients, who received TPE from January 2014 to December 2018, were reviewed retrospectively. The signs or symptoms during and after TPE were analyzed.
RESULTS
TPE sessions were performed on 95 patients. The mean age was 53.3 years and men comprised 63.2%. The most common indication for TPE was desensitization for ABO-incompatible liver transplantation (ABO-i LT) (N=56, 58.9%). A total of 27 patients (28.4%) experienced AE during the initial TPE. The types of AE were allergic reactions (N=14, 14.7%), anaphylactic reaction (N=3, 11.1%), hypotension (N=5, 5.3%), hypocalcemic reaction (N=4, 4.2%), and febrile nonhemolytic reaction (N=1, 1.1%). The severities of AE were evaluated as mild in eight procedures (8.4 %), moderate in seventeen (17.9 %), and severe in two (2.1 %). Multivariable logistic regression analysis showed that the desensitization for ABO-i LT (odds ratio (OR), 2.08; 95% CI, 1.03~4.22) and the amount of FFP (OR, 1.07; 95% CI, 1.01~1.09) were associated with a higher incidence of AE.
CONCLUSION
TPE can be performed under careful patient monitoring to provide prompt intervention, particularly in patients with desensitization of ABO-i LT using FFP.

Keyword

Therapeutic plasma exchange; Risk factors; Adverse events; Allergic reactions

MeSH Terms

Anaphylaxis
Humans
Hypersensitivity
Hypotension
Incidence
Liver Transplantation
Logistic Models
Male
Monitoring, Physiologic
Plasma Exchange*
Plasma*
Retrospective Studies
Risk Factors*