Efficient Verification of X-ray Target Replacement for the C-series High Energy Linear Accelerator

Affiliations
  • 1Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea.
  • 2Biomedical Research Institute, Seoul National University Hospital, Seoul, Korea. jinsung@yuhs.ac
  • 3Department of Radiation Oncology, Yonsei University College of Medicine, Seoul, Korea.
  • 4Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea.
  • 5Center for Convergence Research on Robotics, Advance Institutes of Convergence Technology, Suwon, Korea.

Abstract

The manufacturer of a linear accelerator (LINAC) has reported that the target melting phenomenon could be caused by a non-recommended output setting and the excessive use of monitor unit (MU) with intensity-modulated radiation therapy (IMRT). Due to these reasons, we observed an unexpected beam interruption during the treatment of a patient in our institution. The target status was inspected and a replacement of the target was determined. After the target replacement, the beam profile was adjusted to the machine commissioning beam data, and the absolute doses-to-water for 6 MV and 10 MV photon beams were calibrated according to American Association of Physicists in Medicine (AAPM) Task Group (TG)-51 protocol. To verify the beam data after target replacement, the beam flatness, symmetry, output factor, and percent depth dose (PDD) were measured and compared with the commissioning data. The difference between the referenced and measured data for flatness and symmetry exhibited a coincidence within 0.3% for both 6 MV and 10 MV, and the difference of the PDD at 10 cm depth (PDD₁₀) was also within 0.3% for both photon energies. Also, patient-specific quality assurances (QAs) were performed with gamma analysis using a 2-D diode and ion chamber array detector for eight patients. The average gamma passing rates for all patients for the relative dose distribution was 99.1%±1.0%, and those for absolute dose distribution was 97.2%±2.7%, which means the gamma analysis results were all clinically acceptable. In this study, we recommend that the beam characteristics, such as beam profile, depth dose, and output factors, should be examined. Further, patient-specific QAs should be performed to verify the changes in the overall beam delivery system when a target replacement is inevitable; although it is more important to check the beam output in a daily routine.

Keyword

Linear accelerator; Target degradation; Target melting; Beam verification; IMRT verification

MeSH Terms

Freezing
Humans
Particle Accelerators*

Figure

  • Fig. 1 The punched tungsten target.

  • Fig. 2 Profile comparison between reference (dashed line) and measurement (solid line) for (a) 6 MV, (b) 10 MV photon beam. The measurement condition was as follows: source-to-surface distance (SSD) of 100 cm, reference depth of 10 cm, and field size of 35×35 cm2.

  • Fig. 3 Percentage depth doses comparisons between reference (dashed line) and measurement (solid line) for (a) 6 MV, (b) 10 MV.

  • Fig. 4 Sample gamma analysis graphical user interface (GUI) provided by SNC Patient software (Sun Nuclear Corporation, Melbourne, FL) for verification of intensity-modulated radiation therapy (IMRT) plan.


Reference

1.Low DA., Harms WB., Mutic S., Purdy JA. A technique for the quantitative evaluation of dose distributions. Med Phys. 1998. 25:656–661.
Article
2.Hussein M., Clark CH., Nisbet A. Challenges in calculation of the gamma index in radiotherapy - Towards good practice. Phys Med. 2017. 36:1–11.
Article
3.Dobler B, et al. Hybrid plan verification for intensity-modulated radiation therapy (IMRT) using the 2D ionization chamber array I'mRT MatriXX–a feasibility study. Phys Med Biol. 2010. 55:N39–55.
Article
4.Almond PR, et al. AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams. Med Phys. 1999. 26:1847–70. .7.
5.Lloyd S AM, et al. TG-51 reference dosimetry for the Hal-cyonTM: A clinical experience. J Appl Clin Med Phys. 2018. 19:98–102.
6.Kim JI, et al. A multi-institutional study for tolerance and action levels of IMRT dose quality assurance measurements in Korea. J Appl Clin Med Phys. 2013. 14:24–37.
Article
7.Klein EE, et al. Task Group 142 report: quality assurance of medical accelerators. Med Phys. 2009. 36:4197–4212.
8.Park JM., Park SY., Wu HG., Kim JI. Commissioning Experience of Tri-Cobalt-60 MRI-guided Radiation Therapy System. Prog Med Phys. 2015. 26:193–200.
Article
9.Li JG., Yan G., Liu C. Comparison of two commercial detector arrays for IMRT quality assurance. J Appl Clin Med Phys. 2009. 10:62–72.
Article
10.Steers JM., Fraass BA. IMRT QA: Selecting gamma criteria using error curves. Med. Phys. 2016. 43:1982–1994.
11.So-Yeon Park, et al. Optimal Density Assignment to 2D Diode Array Detector for Different Dose Calculation Al-gorithms in Patient Specific VMAT QA. J Radiat Prot Res. 2017. 42:9–15.
12.Ezzell GA, et al. IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. Med. Phys. 2009. 36:5359–5373.
Article
13.Eclipse Photon and Electron Reference Guide. Document ID P1008611-002-B. Palo Alto, CA, USA: Varian Medical Systems Inc.;2014. 50.
14.Gao S., Balter P., Wang X., Sadagopan R., Pollard J. SU–E–T–245: Detection of the Photon Target Damage in Varian Linac Based On Periodical Quality Assurance Measurements. Med Phys. 2015. 42:3389.
Article
Full Text Links
  • PMP
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr