Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

182 results
Display

LINAC-based High-precision Radiotherapy: Radiosurgery, Image-guided Radiotherapy, and Respiratory-gated Radiotherapy

Kim JH

High precision radiotherapy has been a hot issue to radiation oncologists for the last 100 years. Introduction of mega volt machine with linear accelerators changed the paradigm of radiotherapy, and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Linear Accelerator Radiosurgery for Trigeminal Neuralgia: Case Report

Yun HG

  • KMID: 2323582
  • J Korean Soc Ther Radiol Oncol.
  • 2006 Jun;24(2):144-148.
Trigeminal neuralgia is defined as an episodic electrical shock-like sensation in a dermatomal distribution of the trigeminal nerve. When medications fail to control pain, various procedures are used to attempt...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Proton therapy in pediatric brain tumors

Kim JY

Proton beam therapy (PBT) was initiated in the particle accelerator located in the physics laboratory. As this modality moves from the research laboratory to hospital-based facilities, there has been a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Dosimetry of Irregular Field Using Thermoluminescence Dosimetry

Lee JY, Park KR, Kim KJ

  • KMID: 2196766
  • J Korean Soc Ther Radiol.
  • 1994 Jun;12(2):263-267.
In clinical radiotherapy, the use of wide and irregular field techniques frequently results in considerable tumor dose inhomogeneity because of, the variation in physical characteristics of irradiated volumes. This report...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Analysis of Output Constancy Checks Using Process Control Techniques in Linear Accelerators

Oh SA, Yea JW, Kim SW, Lee R, Kim SK

The purpose of this study is to evaluate the results for the quality assurance through a statistical analysis on the output characteristics of linear accelerators belonging to Yeungnam University Medical...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fabrication of Backscatter Electron Cones for Radiation Therapy

Chu SS, Suh CO, Kim GE

  • KMID: 2323758
  • J Korean Soc Ther Radiol Oncol.
  • 2001 Mar;19(1):74-80.
PURPOSE: Irradiation cones by using backscatter electrons are made for the treatment of superficial small lesions of skin, oral cavity, and rectum where a significant dose gradient and maximum surface...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
New methods for optical distance indicator and gantry angle quality control tests in medical linear accelerators: image processing by using a 3D phantom

Shandiz MH, Layen GS, Anvari K, Khalilzadeh M

PURPOSE: In order to keep the acceptable level of the radiation oncology linear accelerators, it is necessary to apply a reliable quality assurance (QA) program. MATERIALS AND METHODS: The QA protocols,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Linear Accelerator-Based Stereotactic Radiosurgery for Acoustic Neurinomas

Jang HS, Yoon SC, Suh TS, Ryu MR, Kim YS, Kim MC, Kang JK, Shinn KS

  • KMID: 2006791
  • J Korean Cancer Assoc.
  • 1997 Dec;29(6):992-999.
No abstract available
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Study on ARC Therapy of 18MeV Linear Accelerator

Kim SK, Shin SO, Kim MS

In recent years there has been a growing interest in all forms of rotational therapy, and many different types of therapy machines designed for this kind of treatment have become...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Development of a Method to Measure the Radiation Isocenter Size of Linear Accelerators and Quantitative Analysis of the Radiation Isocenter Size for Clinac 21EX Linear Accelerator

Jeon H, Nam J, Park D, Kim YH, Kim W, Kim D, Ki Y, Kim D

  • KMID: 2243877
  • Korean J Med Phys.
  • 2011 Sep;22(3):131-139.
A method to get a size of the radiation isocenter of linear accelerators using star-shot images was presented and a computer program was developed to automate the method. Accuracy of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Study on the 6 MV Photon Beam Characteristics and Analysis Method from Medical Linear Accelerators Using Geant4 Medical Linac2 Example

Kim BY, Kim HD, Kim SJ, Oh SA, Kang JG, Kim SK

  • KMID: 1451820
  • Korean J Med Phys.
  • 2011 Jun;22(2):79-84.
In this study, Geant4 based Monte Carlo simulations were carried out for medical linear accelerator. Modified Medical Linac2 toolkit was used for calculation. The energy spectrum, most probable energy and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Characteristics of 10 MV X-ray Beam from a Mevatron KD Linear Accelerator

Yi BY, Lee MZ

  • KMID: 1657617
  • J Korean Soc Ther Radiol.
  • 1988 Jun;6(1):101-108.
The beam characteristics and dosimetric measurements of the 10 MV X-ray beam from a Mevatron KD linear accelerator are examined. The Percent Depth Dose (PDD) table and the Tissue Maximum...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical Application of Wedge Factor

Choi DR, Ahn YC, Huh SJ

  • KMID: 2196653
  • J Korean Soc Ther Radiol.
  • 1995 Sep;13(3):291-296.
PURPOSE: In general. The wedge factors which are used clinical practives are ignored of dependency on field sizes and depths. In this present, we investigated systematically the depth and field...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Radiation Therapy (RT) of Midline Granuloma

Kwon HC, Oh YK, Gil HJ, Yoon SC, Bahk YW

  • KMID: 1657555
  • J Korean Soc Ther Radiol.
  • 1986 Dec;4(2):135-140.
Seven patients having midline granuloma received local irradiation from March 1983 to June 1986. Clinically, all of the 7 patients had pansinusitis with necrotic destruction of the involved sites and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Dose Characteristics of Small Radiation Fields for 6MV X-ray of Linear Accelerator

Choi TJ, Kim OB, Kim YH, Son EI, Kim IH

  • KMID: 2197210
  • J Korean Soc Ther Radiol.
  • 1989 Dec;7(2):287-292.
Radiation dosimetry has been extended to small fields less than 4x4 cm2 which may be suitable for irradiation of small intracranial tumors. Special consideration was given to the percentage depth...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A case report of radiation therapy of seminoma metastasised to the retroperitoneum and mediastinum

Yoo HS, Choi BS, Lee DH

A case report of seminoma, 45 years old male, was reviewed with references regarding on the argue ofprophylactic mediastinal irradiation versus periaortic and pelvic irradiation alone who had developed metastaticlesion...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Implementation and Evaluation of the Electron Arc Plan on a Commercial Treatment Planning System with a Pencil Beam Algorithm

Kang SK, Park S, Hwang T, Cheong KH, Lee MY, Kim KJ, Oh DH, Bae H

  • KMID: 1460197
  • Korean J Med Phys.
  • 2010 Sep;21(3):304-310.
Less execution of the electron arc treatment could in large part be attributed to the lack of an adequate planning system. Unlike most linear accelerators providing the electron arc mode,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Verification for Multiple Arc Stereotaxic Radiotherapy

Yoon SC, Jang HS, Kim IA, Shinn KS, Bahk YW

  • KMID: 2197149
  • J Korean Soc Ther Radiol.
  • 1990 Jun;8(1):111-114.
External stereotaxic irradiation of intracranial lesions has recently gained its interest in the fields of not only radiation oncology but also neurosurgery. Its main goal is to deliver large doses...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Electron Energy Distribution for a Research Electron LINAC

Lim H, Lee M, Yi J, Kang SK, Kim MY, Jeong DH

The energy distribution was calculated for an electron beam from an electron linear accelerator developed for medical applications using computational methods. The depth dose data for monoenergetic electrons from 0.1...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Dose Alterations at the Distal Surface by Tissue Inhomogeneity in High Energy Phonton Beam

Kim YA, Choi TJ, Kim OB

  • KMID: 2196649
  • J Korean Soc Ther Radiol.
  • 1995 Sep;13(3):277-284.
PURPOSE: This study was performed to measure dose alteration at the air-tissue interface resulting from rebuild-up due to the loss of charged particle equilibrium in the tissues around the air-tissue...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr