Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis

Affiliations
  • 1Department of Prosthodontics, Dentistry School, University of Taubaté, Taubaté, SP, Brazil. rafapvitti@gmail.com

Abstract

PURPOSE
This study evaluated the dimensional stability of a complete-arch prosthesis processed by conventional method in water bath or microwave energy and polymerized by two different curing cycles.
MATERIALS AND METHODS
Forty maxillary complete-arch prostheses were randomly divided into four groups (n = 10): MW1 - acrylic resin cured by one microwave cycle; MW2 - acrylic resin cured by two microwave cycles: WB1 - conventional acrylic resin polymerized using one curing cycle in a water bath; WB2 - conventional acrylic resin polymerized using two curing cycles in a water bath. For evaluation of dimensional stability, occlusal vertical dimension (OVD) and area of contact points were measured in two different measurement times: before and after the polymerization method. A digital caliper was used for OVD measurement. Occlusal contact registration strips were used between maxillary and mandibular dentures to measure the contact points. The images were measured using the software IpWin32, and the differences before and after the polymerization methods were calculated. The data were statistically analyzed using the one-way ANOVA and Tukey test (α = .05).
RESULTS
he results demonstrated significant statistical differences for OVD between different measurement times for all groups. MW1 presented the highest OVD values, while WB2 had the lowest OVD values (P < .05). No statistical differences were found for area of contact points among the groups (P=.7150).
CONCLUSION
The conventional acrylic resin polymerized using two curing cycles in a water bath led to less difference in OVD of complete-arch prosthesis.

Keyword

Denture; Complete; Dental occlusion; Acrylic resins; Polymerization

MeSH Terms

Acrylic Resins
Baths
Dental Occlusion
Dentures
Methods*
Microwaves
Polymerization*
Polymers*
Prostheses and Implants*
Vertical Dimension*
Water
Acrylic Resins
Polymers
Water

Figure

  • Fig. 1 Procedures of the polymerization process used in each group.

  • Fig. 2 Method used for measurement of alterations in occlusal vertical dimension: a digital caliper was used to measure the distance between the upper and lower frame of SAA before and after polymerization.

  • Fig. 3 Standardization of the contact points.

  • Fig. 4 Image already inserted into the software with occlusal contacts marked to have the area measured.


Reference

1. Mahadevan V, Krishnan M, Krishnan CS, Azhagarasan NS, Sampathkumar J, Ramasubramanian H. Influence of surface modifications of acrylic resin teeth on shear bond strength with denture base resin-an invitro study. J Clin Diagn Res. 2015; 9:ZC16–ZC21.
Article
2. Singh S, Palaskar JN, Mittal S. Comparative evaluation of surface porosities in conventional heat polymerized acrylic resin cured by water bath and microwave energy with microwavable acrylic resin cured by microwave energy. Contemp Clin Dent. 2013; 4:147–151.
Article
3. Nishii M. Studies on the curing of denture base resins with microwave irradiation: with particular reference to heat-curing resins. J Osaka Dent Univ. 1968; 2:23–40.
4. Sesma N, Gil C, Kolikauskas WA, Silva RA, Pannuti CM. Temperature of denture base resin under different protocols of microwave irradiation. Braz Dent J. 2011; 22:388–391.
Article
5. Fenlon MR, Juszczyk AS, Rodriguez JM, Curtis RV. Dimensional stability of complete denture permanent acrylic resin denture bases; A comparison of dimensions before and after a second curing cycle. Eur J Prosthodont Restor Dent. 2010; 18:33–38.
6. Wagner AG, Sanders SR. Permanent, heat-cured, acrylic-resin bases for complete dentures. Gen Dent. 1990; 38:138–140.
7. Barbosa DB, Compagnoni MA, Leles CR. Changes in occlusal vertical dimension in microwave processing of complete dentures. Braz Dent J. 2002; 13:197–200.
Article
8. Wolfaardt J, Cleaton-Jones P, Fatti P. The influence of processing variables on dimensional changes of heat-cured poly(methyl methacrylate). J Prosthet Dent. 1986; 55:518–525.
Article
9. Mazaro JV, Gennari Filho H, Vedovatto E, Amoroso AP, Pellizzer EP, Zavanelli AC. Influence of different base thicknesses on maxillary complete denture processing: linear and angular graphic analysis on the movement of artificial teeth. J Craniofac Surg. 2011; 22:1661–1665.
10. Gharechahi J, Asadzadeh N, Shahabian F, Gharechahi M. Flexural strength of acrylic resin denture bases processed by two different methods. J Dent Res Dent Clin Dent Prospects. 2014; 8:148–152.
11. Ribeiro JA, de Resende CM, Lopes AL, Farias-Neto A, Carreiro Ada F. The influence of mandibular ridge anatomy on treatment outcome with conventional complete dentures. Acta Odontol Latinoam. 2014; 27:53–57.
12. Silva-Concilio LR, Meloto CB, Neves ACC, Cunha LG, Rizzatti-Barbosa CM. Influence of different flasking and polymerizing methods on the occlusal vertical dimension of complete dentures. Acta Odontol Latinoam. 2012; 25:312–317.
13. Negreiros WA, Consani RLX, Mesquita MF. Dimensional stability of distances between teeth in complete dentures comparing microwave polymerization and conventional cycles. Braz J Oral Sci. 2010; 9:384–387.
14. Nogueira SS, Ogle RE, Davis EL. Comparison of accuracy between compression- and injection-molded complete dentures. J Prosthet Dent. 1999; 82:291–300.
Article
15. Salloum AM. Influence of high expansion dental stone used as investing medium on the changes in occlusal vertical dimension of complete dentures. Saudi Dent J. 2013; 25:135–140.
Article
16. Pero AC, Barbosa DB, Marra J, Ruvolo-Filho AC, Compagnoni MA. Influence of microwave polymerization method and thickness on porosity of acrylic resin. J Prosthodont. 2008; 17:125–129.
Article
17. Consani RL, Mesquita MF, Sobrinho LC, Sinhoreti MA. Dimensional accuracy of upper complete denture bases: the effect of metallic flask closure methods. Gerodontology. 2009; 26:58–64.
Article
18. Moreno-Hay I, Okeson JP. Does altering the occlusal vertical dimension produce temporomandibular disorders? A literature review. J Oral Rehabil. 2015; 42:875–882.
Article
19. Gross MD, Ormianer Z. A preliminary study on the effect of occlusal vertical dimension increase on mandibular postural rest position. Int J Prosthodont. 1994; 7:216–226.
20. Kimura H, Teraoka F, Ohnishi H, Saito T, Yato M. Application of microwave for dental technique (part 2). Adaptability of cured acrylic resins. J Osaka Univ Dent Sch. 1984; 24:21–29.
21. Aras K, Hasanreisoğlu U, Shinogaya T. Masticatory performance, maximum occlusal force, and occlusal contact area in patients with bilaterally missing molars and distal extension removable partial dentures. Int J Prosthodont. 2009; 22:204–209.
22. Baca E, Yengin E, Gökçen-Röhlig B, Sato S. In vivo evaluation of occlusal contact area and maximum bite force in patients with various types of implant-supported prostheses. Acta Odontol Scand. 2013; 71:1181–1187.
Full Text Links
  • JAP
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr