J Adv Prosthodont.  2017 Jun;9(3):170-175. 10.4047/jap.2017.9.3.170.

Fracture resistances of zirconia, cast Ni-Cr, and fiber-glass composite posts under all-ceramic crowns in endodontically treated premolars

Affiliations
  • 1Department of Prosthodontics, Tehran University of Medical Sciences, International Campus, School of Dentistry, Tehran, Iran. s-habibzadeh@tums.ac.ir
  • 2Department of Prosthodontics, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran.
  • 3Department of Prosthodontics, Tehran University of Medical Sciences, School of Dentistry, Tehran, Iran.
  • 4Tehran University of Medical Sciences, International Campus, School of Dentistry, Tehran, Iran.
  • 5Dental Research Center, Tehran University of Medical Sciences, Tehran, Iran.

Abstract

PURPOSE
The aim of the present study was to evaluate the fracture resistances of zirconia, cast nickel-chromium alloy (Ni-Cr), and fiber-composite post systems under all-ceramic crowns in endodontically treated mandibular first premolars.
MATERIALS AND METHODS
A total of 36 extracted human mandibular premolars were selected, subjected to standard endodontic treatment, and divided into three groups (n=12) as follows: cast Ni-Cr post-and-core, one-piece custom-milled zirconia post-and-core, and prefabricated fiber-glass post with composite resin core. Each specimen had an all-ceramic crown with zirconia coping and was then loaded to failure using a universal testing machine at a cross-head speed of 0.5 mm/min, at an angle of 45 degrees to the long axis of the roots. Fracture resistance and modes of failure were analyzed. The significance of the results was assessed using analysis of variance (ANOVA) and Tukey honest significance difference (HSD) tests (α=.05).
RESULTS
Fiber-glass posts with composite cores showed the highest fracture resistance values (915.70±323 N), and the zirconia post system showed the lowest resistance (435.34±220 N). The corresponding mean value for the Ni-Cr casting post and cores was reported as 780.59±270 N. The differences among the groups were statistically significant (P<.05) for the zirconia group, as tested by ANOVA and Tukey HSD tests.
CONCLUSION
The fracture resistance of zirconia post-and-core systems was found to be significantly lower than those of fiberglass and cast Ni-Cr post systems. Moreover, catastrophic and non-restorable fractures were more prevalent in teeth restored by zirconia posts.

Keyword

Fracture; Endodontically treated teeth; Post and core; Zirconia

MeSH Terms

Alloys
Bicuspid*
Crowns*
Humans
Tooth
Alloys

Figure

  • Fig. 1 Prepared acrylic patterns of post-cores in the first two groups.

  • Fig. 2 A sample and an all ceramic crown with zirconia coping.

  • Fig. 3 Loading of a sample in universal testing machine to the point of fracture.

  • Fig. 4 Error bar and condinfence interval of 95%.

  • Fig. 5 Porcelain fracture in cast Ni-Cr post-core system.


Reference

1. Torabinejad M, Walton RE, Fouad A. Endodontics: Principles and practice. 4th ed. Philadelphia: W.B. Sunders Co;2012. p. 268–282.
2. Berman LH, Hargreaves KM, Cohen SR. Cohen's pathways of the pulp. Elsevier Health Sciences;2013. p. 786–821.
3. Shillingburg HT, Sather DA, Wilson EL Jr, Cain JR, Mitchell DL, Blanco LJ, Kessler JC. Fundamentals of fixed prosthodontics. 4th ed. Quintessence Publishing;2013. p. 203–227.
4. Rosenstiel SF, Land MF, Fujimoto J. Contemporary fixed prosthodontics. 4th ed. Mosby;2006. p. 313–372.
5. Martínez-Insua A, da Silva L, Rilo B, Santana U. Comparison of the fracture resistances of pulpless teeth restored with a cast post and core or carbon-fiber post with a composite core. J Prosthet Dent. 1998; 80:527–532.
6. Glantz PO, Nilner K. The devitalized tooth as an abutment in dentitions with a reduced but healthy periodontium. Periodontol 2000. 1994; 4:52–57.
7. Glazer B. Restoration of endodontically treated teeth with carbon fibre posts-a prospective study. J Can Dent Assoc. 2000; 66:613–618.
8. Luu KQ, Walker RT. Corrosion of a nonprecious metal post: a case report. Quintessence Int. 1992; 23:389–392.
9. Meyenberg KH, Lüthy H, Schärer P. Zirconia posts: a new all-ceramic concept for nonvital abutment teeth. J Esthet Dent. 1995; 7:73–80.
10. Dean JP, Jeansonne BG, Sarkar N. In vitro evaluation of a carbon fiber post. J Endod. 1998; 24:807–810.
11. Stewardson DA. Non-metal post systems. Dent Update. 2001; 28:326–332. 334336
12. Friedel W, Kern M. Fracture strength of teeth restored with all-ceramic posts and cores. Quintessence Int. 2006; 37:289–295.
13. Bittner N, Hill T, Randi A. Evaluation of a one-piece milled zirconia post and core with different post-and-core systems: An in vitro study. J Prosthet Dent. 2010; 103:369–379.
14. Streacker AB, Geissberger M. The milled ceramic post and core: A functional and esthetic alternative. J Prosthet Dent. 2007; 98:486–487.
15. Awad MA, Marghalani TY. Fabrication of a custom-made ceramic post and core using CAD-CAM technology. J Prosthet Dent. 2007; 98:161–162.
16. Stricker EJ, Göhring TN. Influence of different posts and cores on marginal adaptation, fracture resistance, and fracture mode of composite resin crowns on human mandibular premolars. An in vitro study. J Dent. 2006; 34:326–335.
17. Rosentritt M, Fürer C, Behr M, Lang R, Handel G. Comparison of in vitro fracture strength of metallic and tooth-coloured posts and cores. J Oral Rehabil. 2000; 27:595–601.
18. Akkayan B, Gülmez T. Resistance to fracture of endodontically treated teeth restored with different post systems. J Prosthet Dent. 2002; 87:431–437.
19. Heydecke G, Butz F, Hussein A, Strub JR. Fracture strength after dynamic loading of endodontically treated teeth restored with different post-and-core systems. J Prosthet Dent. 2002; 87:438–445.
20. Xible AA, de Jesus Tavarez RR, de Araujo Cdos R, Conti PC, Bonachella WC. Effect of cyclic loading on fracture strength of endodontically treated teeth restored with conventional and esthetic posts. J Appl Oral Sci. 2006; 14:297–303.
21. Gu XH, Huang JP, Wang XX. An experimental study on fracture resistance of metal-ceramic crowned incisors with different post-core systems. Zhonghua Kou Qiang Yi Xue Za Zhi. 2007; 42:169–172.
22. Torres-Sánchez C, Montoya-Salazar V, Córdoba P, Vélez C, Guzmán-Duran A, Gutierrez-Pérez JL, Torres-Lagares D. Fracture resistance of endodontically treated teeth restored with glass fiber reinforced posts and cast gold post and cores cemented with three cements. J Prosthet Dent. 2013; 110:127–133.
23. Aggarwal V, Singla M, Yadav S, Yadav H, Sharma V, Bhasin SS. The effect of ferrule presence and type of dowel on fracture resistance of endodontically treated teeth restored with metal-ceramic crowns. J Conserv Dent. 2014; 17:183–187.
24. Mobilio N, Borelli B, Sorrentino R, Catapano S. Effect of fiber post length and bone level on the fracture resistance of endodontically treated teeth. Dent Mater J. 2013; 32:816–821.
25. Hou QQ, Gao YM, Sun L. Influence of fiber posts on the fracture resistance of endodontically treated premolars with different dental defects. Int J Oral Sci. 2013; 5:167–171.
26. Barcellos RR, Correia DP, Farina AP, Mesquita MF, Ferraz CC, Cecchin D. Fracture resistance of endodontically treated teeth restored with intra-radicular post: the effects of post system and dentine thickness. J Biomech. 2013; 46:2572–2577.
27. Pfeiffer P, Schulz A, Nergiz I, Schmage P. Yield strength of zirconia and glass fibre-reinforced posts. J Oral Rehabil. 2006; 33:70–74.
28. Li Q1, Xu B, Wang Y, Cai Y. Effects of auxiliary fiber posts on endodontically treated teeth with flared canals. Oper Dent. 2011; 36:380–389.
29. Ozkurt Z, Işeri U, Kazazoğlu E. Zirconia ceramic post systems: a literature review and a case report. Dent Mater J. 2010; 29:233–245.
30. Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials. 1999; 20:1–25.
31. Garvie RC, Nicholson PS. Phase analysis in zirconia systems. J Am Ceram Soc. 1972; 55:303–305.
32. Asmussen E, Peutzfeldt A, Heitmann T. Stiffness, elastic limit, and strength of newer types of endodontic posts. J Dent. 1999; 27:275–278.
33. da Silva NR, Raposo LH, Versluis A, Fernandes-Neto AJ, Soares CJ. The effect of post, core, crown type, and ferrule presence on the biomechanical behavior of endodontically treated bovine anterior teeth. J Prosthet Dent. 2010; 104:306–317.
34. Beck N, Graef F, Wichmann M, Karl M. In vitro fracture resistance of copy-milled zirconia ceramic posts. J Prosthet Dent. 2010; 103:40–44.
35. Cormier CJ, Burns DR, Moon P. In vitro comparison of the fracture resistance and failure mode of fiber, ceramic, and conventional post systems at various stages of restoration. J Prosthodont. 2001; 10:26–36.
36. Newman MP, Yaman P, Dennison J, Rafter M, Billy E. Fracture resistance of endodontically treated teeth restored with composite posts. J Prosthet Dent. 2003; 89:360–367.
37. Cohen BI, Pagnillo MK, Condos S, Deutsch AS. Four different core materials measured for fracture strength in combination with five different designs of endodontic posts. J Prosthet Dent. 1996; 76:487–495.
38. Freedman GA. Esthetic post-and-core treatment. Dent Clin North Am. 2001; 45:103–116.
Full Text Links
  • JAP
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr