Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

182 results
Display

Influence of zirconia and lithium disilicate tooth- or implant-supported crowns on wear of antagonistic and adjacent teeth

Rosentritt M, Schumann F, Krifka S, Preis V

PURPOSE: To investigate the influence of crown material (lithium-disilicate, 3Y-TZP zirconia) and abutment type (rigid implant, resin tooth with artificial periodontium) on wear performance of their antagonist teeth and adjacent...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Assessment of Internal Fitness on Resin Crown Fabricated by Digital Light Processing 3D Printer

Kang W, Kim MS, Kim WG

BACKGROUND: Recently, three-dimensional (3D) printing has been hailed as a disruptive technology in dentistry. Among 3D printers, a digital light processing (DLP) 3D printer has certain advantages, such as high...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Influence of preparation design on fracture resistance of different monolithic zirconia crowns: A comparative study

Findakly M, Jasim HH

PURPOSE: The aim of the study was to evaluate and compare the fracture resistance and modes of fracture of monolithic zirconia crowns with two preparation designs. MATERIALS AND METHODS: Forty human...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The fabrication of abutment crowns for existing removable partial denture using CAD/CAM: A clinical report

Chae MJ, Lee CH

Abutment teeth supporting removable partial denture could be faced a number of problems including development of dental caries. If the existing removable partial denture is in clinically acceptable state and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of additional firing process after sintering of monolithic zirconia crown on marginal and internal fitness

Shin MS, Lee H

PURPOSE: To evaluate an effect of additional firing process after sintering of monolithic zirconia crown on marginal and internal fit through three-dimensional analysis. MATERIALS AND METHODS: Ten monolithic zirconia crowns were...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of marginal and internal discrepancies of zirconia crowns fabricated by various digital scan methods

In HS, Cho HW, Jung JH, Kim JM, Kim YL

In this study, marginal and internal discrepancies of zirconia crowns fabricated with the CAD/CAM (computer aided design - computer aided manufacturing) system were compared. Digital impressions were obtained using model...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of physical properties of the various 3D printing temporary crown and bridge resin

Park SJ, Lee HA, Lee SH, Seok S, Lim BS, Kwon JS, Kim KM

Conventional dental resins for crown and bridge fulfill ISO 10477 and ISO 10993 before clinical application. Although 3D printing or rapid prototyping (RP) for the fabrication of temporary crown and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Colorimetric Analysis of Preformed Zirconia Anterior Crowns for Esthetic Restoration

Lee C, Park K, Yang Y, Lee D, Kim J

The purpose of this study was to identify which combination of zirconia crowns and cements is most similar in color to the maxillary primary incisors by varying the color of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Full mouth rehabilitation of a patient with severe tooth erosion with a digital crown lengthening guide

Park Y, Hong SJ, Paek J, Pae A, Kim HS

In the oral cavity, the teeth undergo wear and corrosion throughout their lives. Progressive and constant tooth wear is a natural phenomenon of aging, but wear and corrosion due to...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fabricating an Implant-Supported Crown with Impression Scanning Technology

Lee JH

Computer-aided design and computer-aided manufacturing (CAD/CAM) technology automates the fabrication process of implant-supported prostheses. For the CAD/CAM fabrication of implant-supported crowns, virtual models must be generated by capturing of the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Three-dimensional evaluation of the machinability of monolithic CAD/CAM-generated posterior crowns by nano-hybrid ceramic

Kim JH

The purpose of this study comparatively analyzed the machinability of various dental hybrid blocks manufactured by using the CAD/CAM system. Three hybrid composite blocks (Vita enamic, Lava Ultimate, GC Cerasmart)...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Conservative and esthetic approach in crown fracture of maxillay anterior tooth: tooth fragment reattachment

Jung KH, Kwon EY, Kim SY, Jeon HM, Son SA, Park JK

Crown fractures are the most frequent traumatic injuries to permanent teeth and mainly involve the maxillary incisors due to their exposed position in the dental arch. One option for managing...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Bond Strength of Band on Zirconia Crown with Compomer and Resin Cement

Park C, Lee J, Lee H, Kim J

The aim of this study was to evaluate the compomer cement and resin cement as an orthodontic band cement on zirconia crown. A total of 30 specimens were prepared. Preformed stainless...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
In vivo wear determination of novel CAD/CAM ceramic crowns by using 3D alignment

Aladağ A, Oğuz D, Çömlekoğlu ME, Akan E

PURPOSE: To determine wear amount of single molar crowns, made from four different restoratives, and opposing natural teeth through computerized fabrication techniques using 3D image alignment. MATERIALS AND METHODS: A total...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of color stability, mechanical and chemical properties according to temporary crown resin type

Yang SY, Kwon JY, No JS, Park SY, Park HE, Baek EJ, Im SY, Kwon JS

Objective of this study was to compare the color stability, mechanical and chemical properties of three different types of temporary crown resins. Commercially available powder-liquid (Group PL), light-cured (Group LC)...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Crown Shape and Amount of Tooth Reduction for Primary Anterior Prefabricated Crowns

Kim S, Lim Y, Lee S, Lee N, Jih M

The purpose of this study was to obtain instructions for size selection of prefabricated crown and tooth reduction by 3-dimensional analysis of the size and shape of the maxillary primary...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Prosthetic treatment for Down's syndrome patient with dental cross bite problem using maxillary double crown denture

Doh SJ, Cho JH

Patients with Down's syndrome have several dental complications such as small teeth caused by underdevelopment of dentin and enamel, periodontitis, agenesis of teeth, prolonged retention of primary teeth and malocclusion...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical Report by using hybrid telescopic double crown Removable Partial Denture on a few remaining teeth with severe periodontal disease

Seo JW, Lee CH

The successful results of the treatment using a double crown denture have been reported in several papers for some of the few remaining teeth in patient. In particular, double crown...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Prosthetic treatment for patient with congenital bilateral cleft lip and palate to close oro-nasal communication using maxillary double crown and clasp retained removable denture

Doh SJ, Cho JH

Patients with cleft lip and palate have several problems such as oro-nasal communication, dental cross-bite caused by the insufficient growth of maxilla, poor pronunciation and esthetic problem. Removable denture with...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Prosthetic rehabilitation for patient with hemi-maxillectomy: Obturator combined with a hybrid telescopic double crown using friction pin

Seo JG, Cho JH

When oral cancer develops in the maxilla, oro-nasal communication occurs after surgical treatment including removal of the primary site. Restoration through an obturator is necessary to prevent food from storing...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2023 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr