Korean J Nephrol.  1997 Sep;16(3):524-530.

Comparison of Dialysis Efficiency Between Hemodialysis Using Heparin Bound Hemophan and Routine Hemodialysis with Systemic Heparinization

Affiliations
  • 1Department of Internal Medicine, College of Medicine, Sung Kyun Kwan University, Samsung Seoul Hospital, Seoul, Korea.
  • 2Department of Internal Medicine, College of Medicine, Gyeong Sang National University, Kyungnam, Korea.

Abstract

Although hemodialysis using heparin bound Hemophan(HBH-HD) has been reported to be a possible modality that can be used in patients at high risk of bleeding, the efficiency of HBH-HD is not certain. To investigate the efficiency of HBH- HD, we compared the total blood compartment volume(TBCV), Kt/V and urea clearance of dialyzer(K) of HBH-HD with those of routine hemodialysis with systemic heparinization(R-HD) in the same patients. HBH-HD was switched to R-HD as soon as the bleeding risk had ceased. Before each HBH-HD, heparin solution(1liter, 20IU/ml saline) was recirculated through the Hemophan(Gambro dialyzer, GFS Plus 11) for 1 hour while removing saline solution(700ml/hr) by applying transmembrane pressure gradient, followed by a single pass rinse with 1 liter of saline solution. Then we performed 10 HBH-HD on 10 patients at risk of bleeding. The dilayzer had to be changed due to severe clotting in one patient during HBH-HD so the comparison of above parameters was possible in 9 patients. The duration of each dialysis was possible in 9 patients. The duration of each dialysis was standardized to 4 hours at blood flow of 200 to 250ml/min. During HBH-HD, there was a slight increase in activated partial thromboplastin time(aPTT)(45.02.6 sec) at 15 min after initiation of dialysis from predialysis level (35.81.3 sec), but no increase in aPTT was observed at 60min, 120min, and the end of dialyses. The loss of TBCV(%) of dialyzers was greater in HBH-HD (174%) than in R-HD(51%). The Kt/V and K of HBH-HD, however, were 1.25+/-0.10 and 143+/-3ml/ min, respectively, which did not differ from those of R-HD which were 1.28+/-0.07 and 145+/-4ml/min, respectively. We conclude that the use of heparin bound Hemophan can be an efficient hemodialysis technique in patients at high risk of bleeding, but clotting of the dialyzer should be observed carefully during hemodialysis(values are mean+/-SE).

Keyword

Heparin bound Hemophan; Adequacy; Clotting

MeSH Terms

Dialysis*
Hemorrhage
Heparin*
Humans
Renal Dialysis*
Sodium Chloride
Thromboplastin
Urea
Heparin
Sodium Chloride
Thromboplastin
Urea
Full Text Links
  • KJN
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr