Korean J Nephrol.  1997 Sep;16(3):426-433.

A Prospective Comparative Study Between Manual and Automated Renal Biopsy by Randomized Sampling

Affiliations
  • 1Department of Nephrology, Ajou University School of Medicine, Suwon, Korea.
  • 2Department of Radiology, Ajou University School of Medicine, Suwon, Korea.
  • 3Department of Pathology, Ajou University School of Medicine, Suwon, Korea.

Abstract


OBJECTIVES
Percutaneous renal biopsy may be carried out in several ways. Recently, the use of a spring-loaded biopsy gun has become popularized. There have been much controversies on the tissue adequacy and the incidence of complications when compared to the manual biopsy. The present study was performed to compare tissue adequacy and the incidence of complications between manual biopsy and automated biopsy.
METHODS
We have studied 108 patients in whom the method of renal biopsy was assigned to one of the two methods[14G Tru-cut needle manual bx (group I) and 18G automated gun biopsy(group II)] according to their national resident's identification number in a randomized and prospective manner.
RESULTS
There were 50 patients in group I and 58 patients in group II. There was no difference in gender, age, hemoglobin, prothrombin time, partial thromboplastin time, diastolic and systolic blood pressure pre-biopsy in group I and II. Indications for biopsies were proteinuria accompained by hematuria (37%), proteinuria(34.3%), acute renal failure (9.3%), SLE (8.3%), chronic renal failure (5.6%), hematuria only (5.6%). In Group I the number of passes was 2.4+/-0.8, the glomeruli obtained were 25.3+/-13.2 and the number of glomeruli per pass were 11.6+/-6.5, and in Group II 3.4+/-1.1, 19.4+/-10.8, and 6.8+/-4.0, respectively. These showed a significant difference (p<0.05). In all cases pathological diagnosis were possible. The histology showed IgA nephropathy in 27.8%, MCNS in 14.8%, lupus nephritis in 11.1, MGN in 11.1%, MPGN in 7.4%, and others. The incidence and area of perinephric hematoma demonstrated on ultrasound 24 hours post-biopsy was increased in group I (24%, 937.7+/-640.0mm2 compared to 10.3%, 372.4+/-327.4mm2 in group II) although no statistically significant difference existed. There was no significant difference in gender, age, prothrombin time, partial thromboplastin time, systolic and diastolic blood pressure between the group with and without hematomas. Hematocrit levels before and after biopsy showed a significant difference (34.5+/-8.2, 33.5+/-8.1, p<0.05) in group I, but no significant difference was observed in group II (34.7+/-6.4, 34.8+/-6.4).
CONCLUSION
Both techniques rendered adequate tissue sampling, but the extent of bleeding seems to be more severe with manual 14G Tru-cut needle biopsy.

Keyword

percutaneous renal biopsy; Biopsy gun; Tru-cut needle; Complication; Perinephric hematoma

MeSH Terms

Acute Kidney Injury
Biopsy*
Biopsy, Needle
Blood Pressure
Diagnosis
Glomerulonephritis, IGA
Glomerulonephritis, Membranoproliferative
Hematocrit
Hematoma
Hematuria
Hemorrhage
Humans
Incidence
Kidney Failure, Chronic
Lupus Nephritis
Needles
Partial Thromboplastin Time
Prospective Studies*
Proteinuria
Prothrombin Time
Ultrasonography
Full Text Links
  • KJN
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr