Korean J Blood Transfus.  2010 Dec;21(3):201-209.

External Quality Assurance Survey for the Blood Donor Screening Tests Performed in 2010

Affiliations
  • 1Department of Laboratory Medicine, College of Medicine, Chung-Ang University, Seoul, Korea. chayoung@cau.ac.kr
  • 2Department of Laboratory Medicine, College of Medicine, Konkuk University, Seoul, Korea.

Abstract

BACKGROUND
To prevent blood-borne infections and guarantee safe transfusion, we proposed a quality assurance program for donor screening tests, such as hepatitis B surface antigen (HBsAg) and anti-hepatitis C virus antibody (anti-HCV), by introducing external proficiency testing for the laboratories that perform donor screening tests.
METHODS
The materials for external proficiency testing (PT) were prepared from the HBsAg Standard Panels and anti-HCV Reference Panels provided by the Korea Food and Drug Administration (KFDA), and the normal Human Serum was provided by the Serum Bank of the Korea National Research Resource Center. The external PT materials were sent to 83 laboratories that performed donor screening tests after evaluating their quality.
RESULTS
The results of evaluating the quality of the PT materials were acceptable. All the laboratories receiving the materials answered with a 100% response rate. All the laboratories answered that they obtained positive results for the HBsAg Standard Panel E, H, I and J; however, one laboratory answered in the gray-zone and that lab had negative results for HBsAg Standard Panel C and G. Seventy laboratories (84%) and 42 laboratories (51%) among the total 83 laboratories answered they had positive results for HBsAg Standard Panel B and D, suggesting that many laboratories could not detect a low level of HBsAg. All 83 laboratories answered that they had concordant results for the external PT for anti-HCV.
CONCLUSION
Donor screening laboratories can detect low levels of HBsAg and anti-HCV without any errors and the performance of the laboratories that could not detect low levels of HBsAg remains to be improved. Quality assurance program using external PT with materials that contain various genotypes and mutants should be conducted to maintain the quality of donor screening tests.

Keyword

Donor screening tests; Quality assurance program; Standard serum panel; HBV variants; External proficiency testing

MeSH Terms

Blood Donors
Donor Selection
Genotype
Hepatitis B Surface Antigens
Humans
Korea
Mass Screening
Pyridines
Thiazoles
United States Food and Drug Administration
Viruses
Hepatitis B Surface Antigens
Pyridines
Thiazoles
Full Text Links
  • KJBT
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr