Korean J Clin Pathol.  2002 Feb;22(1):34-41.

Detection of Autoantibodies for Extractable Nuclear Antigens by LG Immunoblot Kit

Affiliations
  • 1Department of Clinical Pathology, University of Ulsan College of Medicine and Asan Medical Center, Seoul, Korea. hboh@www.amc.seoul.kr
  • 2Department of Allergy and Rheumatology, University of Ulsan College of Medicine and Asan Medical Center, Seoul, Korea.
  • 3Life Science Institute, LG Chem Investment, Ltd, Daejon, Korea.

Abstract

BACKGROUND: Identification of antibodies recognizing extractable nuclear antigens (ENAs) is use-ful in the diagnosis and characterization of a variety of connective tissue diseases. Recently, LG ENA Immunoblot (LGCI, Seoul, Korea) was introduced for detecting various autoantibodies to ENAs simultaneously. Performance of this kit was evaluated in this study.
METHODS
Sera from 108 SLE patients and 103 RA patients were tested for the presence of spe-cific autoantibodies to ENAs by LG ENA Immunoblot and DID. Concordance rates in each autoan-tibody were obtained. After discordant results were resolved by EIA (ENA ELISA TEST SYSTEM, Zeus Scientific Inc., NJ, USA) and western blot (ANA Western Blot Immunoassay, IMMCO Diag-nostics Inc., NY, USA), sensitivity and specificity of LG ENA Immunoblot were evaluated. Between-day precision was also tested.
RESULTS
Concordance rates in each autoantibody in two methods were as follows: anti-RNP (88.0%, 95/108; 100%, 103/103), anti-Sm (87.0%, 94/108; 97.1%, 100/103), anti-SSA (94.4%, 102/108; 99.0%, 102/103), anti-SSB (97.2%, 105/108; 98.1%, 101/103), anti-Scl70 (99.1%, 107/108; 100%, 103/103) in SLE and RA patients, respectively. Sensitivity and specificity of Immunoblot were 92.0% and 99.6% for anti-RNP, 100% and 99.6% for anti-Sm, 100% and 98.6% for anti-SSA, 90.0% and 98.5% for anti-SSB, and 100% and 100% for anti-Scl70, respectively. Between-day precisions were 100% in all anti-ENA antibodies.
CONCLUSIONS
LG ENA Immunoblot showed good concordance rates with the conventional DID method and high sensitivity (>90%) and specificity (>98.5%) in detecting all kinds of anti-ENA autoantibodies. LG Immunoblot has another merit in that it can detect several autoantibodies simul-taneously. It is suggested that LG ENA Immunoblot can replace DID for anti-ENA detection without any problem.

Keyword

ENA; LG ENA Immunoblot; Double immunodiffusion; EIA; Western blot

MeSH Terms

Antibodies
Antigens, Nuclear*
Autoantibodies*
Blotting, Western
Connective Tissue Diseases
Diagnosis
Enzyme-Linked Immunosorbent Assay
Humans
Immunoassay
Sensitivity and Specificity
Seoul
Antibodies
Antigens, Nuclear
Autoantibodies