1.Branemark PI., Hansson BO., Adell R., Breine U., Lindstro¨m J., Halle′n O., Ohman A. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg Suppl. 1977. 16:1–132.
2.Adell R., Lekholm U., Rockler B., Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg. 1981. 10:387–416.
Article
3.Adell R., Lekholm U. Surgical procedures. Zarb GA. Branemark PI, Albrektsson T, editors. Tissue-integrated prostheses: Osseointegration in clinical dentistry. Chicago: Quintessence;Publishing. 1985. p. 1–35.
4.Bass SL., Triplett RG. The effects of preoperative resorption and jaw anatomy on implant success. A report of 303 cases. Clin Oral Implants Res. 1991. 2:193–8.
Article
5.Hutton JE., Heath MR., Chai JY., Harnett J., Jemt T., Johns RB., McKenna S., McNamara DC., van Steenberghe D., Taylor R, et al. Factors related to success and failure rates at 3-year follow-up in a multicenter study of overdentures supported by Branemark implants. Int J Oral Maxillofac Implants. 1995. 10:33–42.
6.Friberg B., Jemt T., Lekholm U. Early failures in 4,641 consecutively placed Branemark dental implants: a study from stage 1 surgery to the connection of completed prostheses. Int J Oral Maxillofac Implants. 1991. 6:142–6.
7.Truhlar RS., Morris HF., Ochi S., Winkler S. Second-stage failures related to bone quality in patients receiving endosseous dental implants: DICRG Interim Report No. 7. Dental Implant Clinical Research Group. Implant Dent. 1994. 3:252–5.
8.Jaffin RA., Berman CL. The excessive loss of Branemark fixtures in type IV bone: a 5-year analysis. J Periodontol. 1991. 62:2–4.
Article
9.Levine RA., Clem DS 3rd., Wilson TG Jr., Higginbottom F., Saunders SL. A multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: preliminary results at 6 or more months of loading. Int J Oral Maxillofac Implants. 1997. 12:237–42.
10.Goodacre CJ., Bernal G., Rungcharassaeng K., Kan JY. Clinical complications with implants and implant prostheses. J Prosthet Dent. 2003. 90:121–32.
Article
11.Eriksson AR., Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury: a vital-microscopic study in the rabbit. J Prosthet Dent. 1983. 50:101–7.
Article
12.Cochran DL., Buser D., ten Bruggenkate CM., Weingart D., Taylor TM., Bernard JP., Peters F., Simpson JP. The use of reduced healing times on ITI implants with a sandblasted and acid-etched (SLA) surface: early results from clinical trials on ITI SLA implants. Clin Oral Implants Res. 2002. 13:144–53.
13.Sutter F., Weber HP., Sorensen J., Belser U. The new restorative concept of the ITI dental implant system. Design and engineering. Int J Periodont Restorative Dent. 1993. 13:409–31.
14.Misch CE. Implant design considerations for the posterior regions of the mouth. Implant Dent. 1999. 8:376–86.
Article
15.Strong JT., Misch CE., Bidez MW., Nalluri P. Functional surface area: thread form and diameter optimization for implant body design. Compendium. 1998. 19:4–9.
16.Norton MR. An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design. Clin Oral Implants Res. 1997. 8:290–8.
Article
17.Norton MR. Assessment of cold welding properties of the internal conical interface of two commercially available implant systems. J Prosthet Dent. 1999. 81:159–66.
Article
18.Norton MR. In vitro evaluation of the strength of the conical implant-to-abutment joint in two commercially available implant systems. J Prosthet Dent. 2000. 83:567–71.
Article
19.Fish J., Belytschko T. A first course in finite elements. John Willey & Sons;2007.
20.Chen HL., Gundjian AA. Specific heat of bone. Med Biol Eng. 1976. 14:548–50.
Article
21.Davim JP., Marques N. Dynamical experimental study of friction and wear behaviour of bovine cancellous bone sliding against a metallic counterface in a water lubricated environment. J Mater Proc Tech. 2004. 152:389–94.
Article
22.Davidson SR., David F. James. Measurement of thermal conductivity of bovine cortical bone. Med Eng Phys. 2000. 22:741–7.
23.Hosokawa A., Otani T. Ultrasonic wave propagation in bovine cancellous bone. J Acoust Soc Am. 1997. 101:558–62.
Article
24.Esposito M., Hirsch J., Lekholm U., Thomsen P. Differential diagnosis and treatment strategies for biologic complications and failing oral implants: a review of the literature. Int J Oral Maxillofac Implants. 1999. 14:473–90.
25.Esposito M., Thomsen P., Ericson LE., Sennerby L., Lekholm U. Histopathologic observations on late oral implant failures. Clin Implant Dent Relat Res. 2000. 2:18–32.
Article
26.Lundskog J. Heat and bone tissue. An experimental investigation of the thermal properties of bone and threshold levels for thermal injury. Scand J Plast Reconstr Surg. 1972. 9:1–80.
27.Eriksson AR., Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury: a vital-microscopic study in the rabbit. J Prosthet Dent. 1983. 50:101–7.
Article
28.Sevitt S. Local vascular changes in burned skin. Proc R Soc Med. 1954. 47:225–8.
29.O'Sullivan D., Sennerby L., Meredith N. Measurements comparing the initial stability of five designs of dental implants: a human cadaver study. Clin Implant Dent Relat Res. 2000. 2:85–92.
30.Park JH., Lim YJ., Kim MJ., Kwon HB. The effect of various thread designs on the initial stability of taper implants. J Adv Prosthodont. 2009. 1:19–25.
Article
31.Huh JB., Ko SM. The comparative study of thermal inductive effect between internal connection and external connection implant in abutment preparation. J Korean Acad Prosthodont. 2007. 45:60–70.
32.Cho JM., Cho U., Yun MJ., Jeong CM., Jeon YC. Influence of implant diameter and length changes on initial stability J Korean Acad Prosthodont. 2009. 47:335–41.
33.Kim SH., Kim SJ., Lee KW., Han DH. The effects of local factors on the survival of dental implants: A 19 year retrospective study. J Korean Acad Prosthodont. 2010. 48:28–40.
Article