PURPOSE: To review the clinical and radiological results after an open reduction and internal fixation with a T-shaped LCP for unstable distal clavicle fractures.
MATERIALS AND METHODS
From February 2005 to June 2006, ten patients with distal clavicle Neer type II fractures were treated with an open reduction and internal fixation with a T-shaped LCP. Bony union was identified by plain radiography. The clinical results were analyzed according to the UCLA scoring system.
RESULTS
The mean time to fracture union was 9weeks and union was achieved in all cases. The mean UCLA score was 33.4 (30-35); excellent in 8 cases and good in 2 cases. In one case, loosening of one distal screw was occured and mild AC joint subluxation was observed in another case.
CONCLUSION
3.5 mm T-shaped LCP fixation is a useful technique for treating unstable distal clavicle fractures. This procedure provide stable fixation with no further AC joint injury.