J Korean Fract Soc.  2009 Oct;22(4):264-269. 10.12671/jkfs.2009.22.4.264.

Short Term Results of Operative Management with 2.4 mm Volar Locking Compression Plates in Distal Radius Fractures

Affiliations
  • 1Department of Orthopaedic Surgery, Guri Hospital, Hanyang University College of Medicine, Guri, Korea. kcpark@hanyang.ac.kr
  • 2Department of Orthopaedic Surgery, Hanyang University College of Medicine, Seoul, Korea.

Abstract

PURPOSE
To evaluate the short term outcome of internal fixation using 2.4 mm volar locking compression plate for the treatment of unstable distal radius fractures. MATERIALS AND METHODS: We retrospectively analyzed the results in 22 cases, which were treated with 2.4 mm volar locking compression plate. We evaluated the radiologic results and the clinical results according to Disabilities of the Arm, Shoulder and Hand (DASH) score and visual analogue scale. RESULTS: At final follow up, the mean VAS was 1.2 and mean DASH score was 10. Average loss of reduction from initial postoperative to final follow up radiographs was 0.36 mm of radial length, 0.2degrees of radial inclination, 0.6degrees of volar tilt. CONCLUSION: Fixation of unstable dorsally displaced distal radius fractures with a 2.4 mm volar locking compression plate provides sufficient stability with minimal loss of reduction and good enough clinical outcomes with less complications.

Keyword

Distal radius fracture; 2.4 mm volar locking compression plate

MeSH Terms

Arm
Follow-Up Studies
Hand
Radius
Radius Fractures
Retrospective Studies
Shoulder

Figure

  • Fig. 1 3.5 mm T-LCP (A), 2.4 mm volar extra-articular (B) and juxta-articular distal radius T-LCP (C). 2.4 mm volar distal radius T-LCPs have five smaller holes than 3.5 mm T-LCP on the head.

  • Fig. 2 (A) Complex intra-articular fracture in a 52-year-old woman. Computed tomography scans demonstrate the intra-articular fracture. (B) Anteroposterior and lateral radiographs are made ten months after volar fixation with 2.4 mm juxta-articular T-shaped locking compression plate.


Cited by  2 articles

2.4 mm Volar Locking Compression Plate for Treatment of Unstable Distal Radius Fractures
Sung-Jin Kim, Chul-Hyun Cho
J Korean Fract Soc. 2011;24(2):151-155.    doi: 10.12671/jkfs.2011.24.2.151.

Treatment of Fractures of the Distal Radius Using Variable-Angle Volar Locking Plate
Jae-Cheon Sim, Sung-Sik Ha, Ki-Do Hong, Tae-Ho Kim, Min-Chul Sung
J Korean Fract Soc. 2015;28(1):46-52.    doi: 10.12671/jkfs.2015.28.1.46.


Reference

1. Amadio PC, Silverstein MD, Ilstrup DM, Schleck CD, Jensen LM. Outcome after Colles fracture: the relative responsiveness of three questionnaires and physical examination measures. J Hand Surg Am. 1996; 21:781–787.
Article
2. Arora R, Lutz M, Fritz D, Zimmermann R, Oberladstätter J, Gabl M. Palmar locking plate for treatment of unstable dorsal dislocated distal radius fractures. Arch Orthop Trauma Surg. 2005; 125:399–404.
Article
3. Cho CH, Bae KC, Kwon DH. Volar T-locking compression plate for treatment of unstable distal radius fractures. J Korean Fract Soc. 2008; 21:220–224.
Article
4. Chung KC, Watt AJ, Kotsis SV, Margaliot Z, Haase SC, Kim HM. Treatment of unstable distal radial fractures with volar locking plating system. J Bone Joint Surg Am. 2006; 88:2687–2694.
Article
5. Constantine KJ, Clawson MC, Stern PJ. Volar neutralization plate fixation of dorsally displaced distal radius fractures. Orthopedics. 2002; 25:125–128.
Article
6. Dowrick AS, Gabbe BJ, Williamson OD, Cameron PA. Does the disabilities of the arm, shoulder and hand (DASH) scoring system only measure disability due to injuries to the upper limb? J Bone Joint Surg Br. 2006; 88:524–527.
Article
7. Drobetz H, Kutscha-Lissberg E. Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop. 2003; 27:1–6.
Article
8. Gummesson C, Ward MM, Atroshi I. The shortened disabilities of the arm, shoulder and hand questionnaire (QuickDASH): validity and reliability based on responses within the full-length DASH. BMC Musculoskelet Disord. 2006; 7:44.
9. Haidukewych GJ. Innovations in locking plate technology. J Am Acad Orthop Surg. 2004; 12:205–212.
Article
10. Jupiter JB, Marent-Huber M. LCP Stud Group. Operative management of distal radial factures with 2.4-millimeter locking plates. A multicenter prospective case series. J Bone Joint Surg Am. 2009; 91:55–65.
Article
11. Koval KJ, Hoehl JJ, Kummer FJ, Simon JA. Distal femoral fixation: a biomechanical comparison of the standard condylar buttress plate, a locking buttress plate and the 95-degree blade plat. J Orthop Trauma. 1997; 11:521–524.
Article
12. Lee KH. Clinical biomechanics of the locking plate. J Korean Fract Soc. 2008; 21:186–188.
Article
13. Lee KH. Volar plating of distal radius fractures. J Korean Fract Soc. 2008; 21:325–333.
Article
14. Matheson LN, Melhorn JM, Mayer TG, Theodore BR, Gatchel RJ. Reliability of a visual analog version of QuickDASH. J Bone Joint Surg Am. 2006; 88:1782–1787.
15. Musgrave DS, Idler RS. Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates. J Hand Surg Am. 2005; 30:743–749.
Article
16. Orbay JL. The treatment of unstable distal radius fractures with volar fixation. Hand Surg. 2000; 5:103–112.
Article
17. Orbay JL. Volar plate fixation of distal radius fractures. Hand Clin. 2005; 21:347–354.
Article
18. Orbay JL, Fernandez DL. Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg Am. 2004; 29:96–102.
Article
19. Pichon H, Chergaoui A, Jager S, et al. Volar fixed angle plate LCP 3.5 for dorsally distal radius fracture. About 24 cases. Rev Chir Orthop Reparatrice Appar Mot. 2008; 94:152–159.
20. Scheck M. Long-term follow-up of treatment of comminuted fractures of the distal end of the radius by transfixation with kirschner wires and cast. J Bone Joint Surg Am. 1962; 44:337–351.
Article
21. Strohm PC, Müller CA, Helwig P, Mohr B, Südkamp NP. Is the locking, 3.5 mm Palmar T-Plate the implant of choice for displaced distal radius fractures? Z Orthop Unfall. 2007; 145:331–337.
Article
22. Tejwani NC, Wolinsky P. The changing face of orthopaedic trauma: locked plating and minimally invasive techniques. Instr Course Lect. 2008; 57:3–9.
Full Text Links
  • JKFS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles