Hanyang Med Rev.  2012 Feb;32(1):45-50. 10.7599/hmr.2012.32.1.45.

Medical Education Using the High-Fidelity Medical Simulator

Affiliations
  • 1Department of Emergency Medicine, Hanyang University College of Medicine, Seoul, Korea. erthim@hanyang.ac.kr

Abstract

Medical education using the high-fidelity simulator has developed rapidly in the last twenty years. Simulation-based medical education is now recognized as one of the powerful complementary teaching methods in the medical profession. It is driven by the combination of the following forces; patient safety movement, constructive learning theory, objective structured clinical examination, patient right movement, medicolegal atmosphere and simulation industry. During the last decade in Korea, the number of simulation centers and high-fidelity simulators has increased rapidly, but the development and implementation of the simulation program has not yet been achieved. In this review, I will discuss the history of the development of the high-fidelity simulator, current status and problems of medical simulation using the high-fidelity simulators in Korea.

Keyword

Computer Simulation; Models, Educational; Patient Safety

MeSH Terms

Atmosphere
Computer Simulation
Education, Medical
Korea
Learning
Models, Educational
Patient Rights
Patient Safety
Teaching

Reference

1. Kohn LT, Corrigan J, Donaldson MS. Institute of Medicine, Committee on Quality of Health Care in America. To err is human: building a safer health system. 2000. Washington, D.C: National Academy Press;1–5.
Article
2. Denson JS, Abrahamson S. A computer-controlled patient simulator. JAMA. 1969. 208:504–508.
Article
3. Cooper JB, Taqueti VR. A brief history of the development of mannequin simulators for clinical education and training. Qual Saf Health Care. 2004. 13:Suppl 1. i11–i18.
Article
4. Lampotang S, Ohrn MA, van Meurs WL. A simulator-based respiratory physiology workshop. Acad Med. 1996. 71:526–527.
Article
5. Chopra V, Gesink BJ, de Jong J, Bovill JG, Spierdijk J, Brand R. Does training on an anaesthesia simulator lead to improvement in performance? Br J Anaesth. 1994. 73:293–297.
6. Holzman RS, Cooper JB, Gaba DM, Philip JH, Small SD, Feinstein D. Anesthesia crisis resource management: real-life simulation training in operating room crises. J Clin Anesth. 1995. 7:675–687.
7. Gaba DM, Howard SK, Flanagan B, Smith BE, Fish KJ, Botney R. Assessment of clinical performance during simulated crises using both technical and behavioral ratings. Anesthesiology. 1998. 89:8–18.
8. Karnath B, Thornton W, Frye AW. Teaching and testing physical examination skills without the use of patients. Acad Med. 2002. 77:753.
9. Rogers PL, Jacob H, Thomas EA, Harwell M, Willenkin RL, Pinsky MR. Medical students can learn the basic application, analytic, evaluative, and psychomotor skills of critical care medicine. Crit Care Med. 2000. 28:550–554.
10. Gordon JA, Pawlowski J. Education on-demand: the development of a simulator-based medical education service. Acad Med. 2002. 77:751–752.
11. Issenberg SB, McGaghie WC, Petrusa ER, Lee Gordon D, Scalese RJ. Features and uses of high-fidelity medical simulations that lead to effective learning: a BEME systematic review. Med Teach. 2005. 27:10–28.
12. Okuda Y, Bond W, Bonfante G, McLaughlin S, Spillane L, Wang E, et al. National growth in simulation training within emergency medicine residency programs, 2003-2008. Acad Emerg Med. 2008. 15:1113–1116.
13. Binstadt ES, Walls RM, White BA, Nadel ES, Takayesu JK, Barker TD, et al. A comprehensive medical simulation education curriculum for emergency medicine residents. Ann Emerg Med. 2007. 49:495–504.
14. World simulation center database [Internet]. Bristol Medical Simulation Center. c2011. cited 2011 Dec 11. Bristol (UK): Bristol Medical Simulation Center;Available from: http://www.bmsc.co.uk.
15. Cook DA, Hatala R, Brydges R, Zendejas B, Szostek JH, Wang AT, et al. Technology-enhanced simulation for health professions education: a systematic review and meta-analysis. JAMA. 2011. 306:978–988.
16. Dent JA, Harden RM. A practical guide for medical teachers. 2009. 3rd ed. Philadelphia: Churchill Livingstone;217–222.
17. Kim YM, Oh YM, Kim HJ, Lee WJ, Im TH, Chung HS, et al. Development and pilot applications of simulation-based comprehensive emergency airway management courses. J Korean Soc Emerg Med. 2007. 18:1–9.
18. Park JH, Jung E, Ko JK, Yoo HB. Delivery training for undergraduate medical students using birth simulator. Korean J Obstet Gynecol. 2008. 51:950–956.
19. Baek HJ, Kim YM, Jung SK, Park SH, Park KN, Park JE. Development and pilot applications of simulation-based emergency department crisis management team training program. J Korean Soc Emerg Med. 2008. 19:603–610.
20. Byeon GJ, Lee HJ, Kim HK, Song BJ, Kim JY, Yeom SR. The effect of repetition of simulation-based cardiopulmonary resuscitation training on the satisfaction of the trainee. Anesth Pain Med. 2011. 6:195–201.
21. Global minimum essential requirements in medical education [Internet]. Institute for International Medical Education. c1999-2006. cited 2011 Dec 11. New York (NY): Institute for International Medical Education;Available from: http://www.iime.org/gmer.htm.
22. Leach DC. Evaluation of competency: an ACGME perspective. Accreditation Council for Graduate Medical Education. Am J Phys Med Rehabil. 2000. 79:487–489.
Full Text Links
  • HMR
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr