J Korean Soc Echocardiogr.  1997 Jul;5(1):5-12.

Adenosine Triphosphate Stress Echocardiography

Affiliations
  • 1Department of Cardiology, Ajou University, School of Medicine, Suwon, Korea.

Abstract

BACKGROUND: Stress echocardiography have been emerged as an important non-invasive diagnostic tool to detect coronary artery disease. Previous studies indicated that adenosine triphosphate(ATP) is a potent coronary vasodilator as adenosine, the time of action onset and half-life is shorter than dipyridamole, the duration of adverse effect is transient and the use of aminophylline is not needed when side effects develop. The purpose of this study was to evaluate the feasibility and diagnostic accuracy of ATP stress echocardiography in patient with suspected coronary artery disease. METHOD: We investigated 20 patients(mean age 56+/-11, male 11, female 9) who underwent stress echocardiography with ATP infusion(0.15 mg/kg/min for 4 min) and quantitative coronary angiography(QCA). The digitized echocardiographic images were analyzed using wall motion score(1: normal, 2: hypokinesia, 3: akinesia, 4: dyskinesia) in 16 segments. Positivity of ATP stress echocardiography was based on the detection of transient regional wall motion abnormality. The hemodynamic changes and occurrence of adverse effects was carefully monitored.
RESULTS
Forteen out of 20 patients had coronary artery disease(>50% diameter stenosis by QCA). Nine out of 14 patients had transient regional wall motion abnormality at coronary artery disease territory(sensitivity 64%). The mean wall motion score index in patients mth positive test was 1.01+0.01 at base and 1.20+0.08 during ATP infusion(p<0.05). Six out of 20 patients who had no regional wall motion abnormality had no coronary artery disease (specificity 100%) with overall diagnostic accuracy of 75%. ATP stress echocardiography showed good agreernent with QCA(kappa value 0.52). Side effect profile revealed chest pain in 6 patients(30%), facial flushing in 3 patients(15%), Wenchebach type AV block in 2 patients(10%) and significant ST-segrnent depression in 1 patients(5%). The mean heart rate, mean systolic and diastolic blood pressure, and mean rate-pressure product were not changed significantly.
CONCLUSION
ATP stress echocardiography is feasible and has a diagnostic value similar to that of adenosine and dipyridamole for detecting coronary artery disease with low cost. In addition, it may have minimal side effects and insignificant clinical consequences.

Keyword

Adenosine triphosphate; Coronary artery disease5

MeSH Terms

Adenosine Triphosphate*
Adenosine*
Aminophylline
Atrioventricular Block
Blood Pressure
Chest Pain
Constriction, Pathologic
Coronary Artery Disease
Coronary Vessels
Depression
Dipyridamole
Echocardiography
Echocardiography, Stress*
Female
Flushing
Half-Life
Heart Rate
Hemodynamics
Humans
Hypokinesia
Male
Adenosine
Adenosine Triphosphate
Aminophylline
Dipyridamole
Full Text Links
  • JKSE
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr