Korean J Anesthesiol.  1997 Mar;32(3):403-409. 10.4097/kjae.1997.32.3.403.

The Effect of Intratracheal Nebulized Lidocaine and Intravenous Lidocaine on the Cardiovascular Stimulating Response to Tracheal Intubation

Affiliations
  • 1Department of Anesthesiology, College of Dentistry, Chonnam National University, Kwang-Ju, Korea.
  • 2Department of Anesthesiology, College of Medicine, Chonnam National University, Kwang-Ju, Korea.
  • 3Department of Anesthesiology, Seoul National University College of Medicine, Seoul, Korea.

Abstract

BACKGROUND
Hypertension and tachycardia usually accompany laryngoscopy and tracheal intubation. Topical and intravenous lidocaine are used in an attempt to blunt these potentially adverse hemodynamic responses, but these effects of lidocaine are controversial. The purpose of this study is to evaluate whether intratracheal nebulized lidocaine and/or intravenous lidocaine attenuate circulatory stimulating response to tracheal intubation.
METHODS
Sixty patients, ASA physical status I, scheduled elective surgery, were randomly assigned to receive a preintubation dose of either 5 mL of normal saline intravenously, 4 mL of 4% lidocaine by intratracheal nebulizer, 1.5 mg/kg of 2% lidocaine intravenously, or 4 mL of 4% lidocaine intratracheal nebulizer and 2% lidocaine of 1.5 mg/kg intravenouly. Induction of anesthesia was accomplished with 5 mg/kg of thiopental IV, and 1 mg/kg of succinylcholine was given. Laryngoscopy and intubation was performed, and anesthesia maintained with 2% enflurane in 50% nitrous oxide in oxygen. Blood pressure and heart rate were recorded at preinduction, after induction, and every minute until 5 min after intubation.
RESULTS
Intratracheal nebulized lidocaine and/or intravenous lidocaine were effective in attenuating increases in systolic pressure with no detectable difference between them, and failed to attenuate increases in diastolic pressure and heart rate. And significant decrease in systolic pressure 3 min after intubation was detected in intratracheal and intravenous lidocaine group.
CONCLUSIONS
These data suggest that intratracheal nebulized lidocaine or intravenous lidocaine is effective in attenuating increase in systolic pressure to tracheal intubation, but intratracheal and intravenous lidocaine has not synergistic effect.

Keyword

Anesthesia; pediatric; fresh gas flow rate; Breathing circuit; mapleson D system; Carbon dioxide; arterial; end-tidal

MeSH Terms

Anesthesia
Blood Pressure
Carbon Dioxide
Enflurane
Heart Rate
Hemodynamics
Humans
Hypertension
Intubation*
Laryngoscopy
Lidocaine*
Nebulizers and Vaporizers
Nitrous Oxide
Oxygen
Succinylcholine
Tachycardia
Thiopental
Carbon Dioxide
Enflurane
Lidocaine
Nitrous Oxide
Oxygen
Succinylcholine
Thiopental
Full Text Links
  • KJAE
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr