J Korean Radiol Soc.  1994 Dec;31(6):1127-1132.

Usefulness of Automated Biopsy Guns in Image-guided Biopsy

Abstract

PURPOSE
To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver. pancreas and other organs.
MATERIALS AND METHODS
Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed:Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications.
RESULTS
Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria & 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously.
CONCLUSION
The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis.


MeSH Terms

Biopsy*
Diagnosis
Firearms*
Gastrointestinal Hemorrhage
Hematuria
Image-Guided Biopsy*
Liver
Lung
Pancreas
Pneumothorax
Retrospective Studies
Full Text Links
  • JKRS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr