Korean J Nucl Med.  2003 Apr;37(2):73-82.

Development of Gated Myocardial SPECT Analysis Software and Evaluation of Left Ventricular Contraction Function

Affiliations
  • 1Department of Information & Computer Engineering, Inje University, Korea.
  • 2Department of Nuclear Medicine, Seoul National University College of Medicine, Korea. dsl@plaza.snu.ac.kr

Abstract


OBJECTIVES
A new software (Cardiac SPECT Analyzer: CSA) was developed for quantification of volumes and ejection fraction on gated myocardial SPECT. Volumes and ejection fraction by CSA were validated by comparing with those quantified by Quantitative Gated SPECT (QGS) software. MATERIALS AND METHODS: Gated myocardial SPECT was performed in 40 patients with ejection fraction from 15% to 85%. In 26 patients, gated myocardial SPECT was acquired again with the patients in situ. A cylinder model was used to eliminate noise semi-automatically and profile data was extracted using Gaussian fitting after smoothing. The boundary points of endo- and epicardium were found using an iterative learning algorithm. Enddiastolic (EDV) and endsystolic volumes (ESV) and ejection fraction (EF) were calculated. These values were compared with those calculated by QGS and the same gated SPECT data was repeatedly quantified by CSA and variation of the values on sequential measurements of the same patients on the repeated acquisition. RESULTS: From the 40 patient data, EF, EDV and ESV by CSA were correlated with those by QGS with the correlation coefficients of 0.97, 0.92, 0.96. Two standard deviation (SD) of EF on Bland Altman plot was 10.1%. Repeated measurements of EF, EDV, and ESV by CSA were correlated with each other with the coefficients of 0.96, 0.99, and 0.99 for EF, EDV and ESV respectively. On repeated acquisition, reproducibility was also excellent with correlation coefficients of 0.89, 0.97, 0.98, and coefficient of variation of 8.2%, 5.4mL, 8.5mL and 2SD of 10.6%, 21.2mL, and 16.4mL on Bland Altman plot for EF, EDV and ESV. CONCLUSION: We developed the software of CSA for quantification of volumes and ejection fraction on gated myocardial SPECT. Volumes and ejection fraction quantified using this software was found valid for its correctness and precision.

Keyword

gated myocardial SPECT; quantification; ejection fraction

MeSH Terms

Humans
Learning
Noise
Pericardium
Tomography, Emission-Computed, Single-Photon*
Full Text Links
  • KJNM
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr