Korean J Anesthesiol.  2000 Feb;38(2):251-257. 10.4097/kjae.2000.38.2.251.

The Bispectral Index and Modified Observer's Assessment of Alertness/Sedation Scale Comparable to Effect Site Concentration of Propofol in Koreans

Affiliations
  • 1Department of Anesthesiology, College of Medicine, Hallym University, Seoul, Korea.
  • 2Department of Anesthesiology, College of Medicine, Han Yang University, Seoul, Korea.

Abstract

BACKGROUND: Propofol has been frequently used for sedation or hypnosis in anesthesia and is relatively accurate in the dose-response relationship for hypnosis. The aim of this study was to define the bispectral index and modified observer's assessment of alertness/sedation (OAA/S) scale at various effect site concentrations (Ce) of propofol in Koreans.
METHODS
Fifty premedicated (atropine 0.5 mg, I.M.) adult patients (ASA class I or II, 20 55 yrs) scheduled for elective orthopedic surgery were studied. Propofol was infused until 2 min after the target concentration equilibrated with the effect site concentration (Ce) of propofol using Master TCI. The target concentration of propofol was stepwise increased at intervals of 0.5 microgram/ml until BIS reached 40, BIS and OAA/S at each Ce of propofol were checked. If SpO2 decreased below 90%, oxygen (4 l/min) was given via nasal cannula.
RESULTS
BIS was 97.9 +/- 0.2 and OAA/S 5 +/- 0.0 at a Ce of propofol of 0 microgram/ml; the Ce of propofol was 3.5 microgram/ml and OAA/S 0.1 +/- 0.3 at a BIS of 41.1 +/- 2.5. Also, systolic BP at a Ce of propofol above 1.0 microgram/ml and diasolic BP at a Ce of propofol above 1.5 microgram/ml significantly decreased compared to the control (P < 0.05). However, heart rate did not show any difference compared to the control value. Above a 1.0 microgram/ml Ce, fifty-eight percent of patients showed SpO2 < 90%, but there was no incidence of apnea. There were significant correlations between Ce of propofol, BIS and OAA/S.
CONCLUSIONS
BIS showed a significant correlation with Ce of propofol (Spearman's r = 1.0) (P < 0.0001). The Ce of propofol was above 3.0 microgram/ml for BIS50.

Keyword

Anesthetic equipment: bispectral index; monitoring device; Pharmacology: effect site concentration; Sedation: OAA/S (modified observer's assessment of alertness/sedation) scale

MeSH Terms

Adult
Anesthesia
Apnea
Catheters
Heart Rate
Humans
Hypnosis
Incidence
Orthopedics
Oxygen
Propofol*
Oxygen
Propofol
Full Text Links
  • KJAE
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles