J Korean Soc Spine Surg.  2013 Dec;20(4):163-168. 10.4184/jkss.2013.20.4.163.

Adjacent Vertebral Compression Fracture after Percutaneous Vertebroplasty

Affiliations
  • 1Department of Orthopedic Surgery, Ulsan University, Medical College, Gangneung Asan Hospital, Gangneung, Korea. jkhwang@gnah.co.kr

Abstract

STUDY DESIGN: A retrospective study.
OBJECTIVES
To find out the characteristics and the risk factors of adjacent vertebral compression fracture after percutaneous vertebroplasty. SUMMARY OF LITERATURE REVIEW: Percutaneous vertebroplasty is regarded as more effective treatment than conservative care, but additional fracture could cause complications during follow up.
MATERIALS AND METHODS
We analyzed 43 patients who had only one vertebral compression fracture after one vertebroplasty. The number of patients who had additional compression fracture within one level from the operated vertebra were 23 cases (Group I); beyond two levels from the operated vertebra were 20 cases (Group II). We compared the onset period of additional compression fracture, the degree of osteoporosis, age, level, restoration of vertebral body height and kyphosis between the two groups.
RESULTS
The onset period of additional compression fracture was 18.7+/-28.1 months in Group I and 42.7+/-39.4 months in Group II, showing significant difference between the two groups. Group I had more cases of previous vertebroplasty on thoraco-lumbar vertebra than Group II. The restoration rate of vertebral body height of Group I was 42.3+/-40.9% and that of Group II was 22.8+/-21.6%, which shows significant difference between the two.
CONCLUSION
Adjacent vertebral compression fracture after vertebroplasty can occur earlier than non adjacent one. We need to pay attention to the patients who had higher restoration rate of vertebral body height after vertebroplsty as they are more prone to having additional adjacent compression fracture.

Keyword

Osteoporosis; Compression fracture; Percutaneous vertebroplasty; Adjacent vertebral fracture; Restoration rate of vertebral body height

MeSH Terms

Body Height
Follow-Up Studies
Fractures, Compression*
Humans
Kyphosis
Osteoporosis
Retrospective Studies
Risk Factors
Spine
Vertebroplasty*

Cited by  1 articles

Early Onset Subsequent Vertebral Compression Fracture after Percutaneous Verteroplasty
Jong-Kil Kim, Byeong-Yeol Choi, Young-Chul Park, Dong-Hyun Kim
J Korean Orthop Assoc. 2019;54(1):24-29.    doi: 10.4055/jkoa.2019.54.1.24.


Reference

1. Barath K, Martin JB, Fasel HJ, et al. Percutaneous vertebroplasty: method indications, results. Orv Hetil. 2003; 143:2469–77.
3. Evans AJ, Jensen ME, Kip KE, et al. Vertebral compression fracture: pain reduction and improvement in fuctional mobility after percutaneous polymethyl methacrylate vertebroplasty retrospective report of 2455 cases. Radiology. 2003; 226:366–72.
4. Gangi A, Kastler BA, Dietmann JL. Perctanteous vertebroplasty guided by a combination of CT and fluoroscopy. AJNR Am J Neuroradiol. 1994; 15:83–6.
5. Kim CH, Choi YJ, Baek SK, et al. Vertebroplasty on osteoporotic compression fracture. J Korean Soc Fract. 2002; 15:124–8.
Article
6. Barr JD, Barr MS, Lemley TJ, McCann RM. Percutaneous vertebroplasty for pain relief and spinal stabilization. Spine (Phila Pa 1976). 2000; 25:923–8.
Article
7. Grados F, Depriester C, Cayrolle G, Hardy N, Deramond H, Fardellone P. Longterm observations of vertebral os-teoportotic fractures treated by percutaenous vertebroplasty. Rheumatology (Oxford). 2000; 39:1410–4.
8. Jensen ME, Dion JE. Percutaneous vertebroplasty in the treatment of osteoporotic compression fracture. Neuroim-aging Clin N Am. 2000; 10:547–68.
9. Zoarski GH, Snow P, Olan WJ. Percutaneous vertebroplasty for osteoporotic compression fractures: quantitative prospective evaluation of longterm outcomes. J Vasc Interv Radiol. 2002; 13:139–48.
Article
10. Kim MH, Min SH, Jeon SH. Risk factors of new compression fractures in adjacent vertebrae after percutaneous vertebroplasty. J Korean Soc Fract. 2007; 20:260–5.
Article
11. Kim SH, Kang HS, Choi JA, Ahn JM. Risk factors of new compression fractures in adjacent vertebrae after percutaneous vertebroplasty. Acta Radiol. 2004; 45:440–5.
Article
12. Diamond TH, Champion B, Clark WA. Management of acute osteoporotic vertebral compression fractures: non-randomized trial comparing percutaneous vertebroplasty with conservative therapy. Am J Med. 2003; 114:257–65.
13. Belkoff SM, Mathis JM, Erbe EM, Fenton DC. Biomechanical evaluation of a new bone cement for use in vertebroplasty. Spine (Phila Pa 1976). 2000; 25:1061–4.
Article
14. Berlemann U, Ferguson SJ, Nolte LP, Heini PF. Adjacent vertebral failure after vertebroplasty. A biomechanical investigation. J Bone Joint Surg Br. 2000; 84:748–52.
15. Wasnich RD. Vertebral Fracture epidemiology. Bone. 1996; 18(3 Suppl):179S–83S.
Article
16. Lindsay R, Silverman S, Cooper C, et al. Risk of new vertebral fracture in the year following a fracture. JAMA. 2001; 285:320–3.
Article
17. Cyteval C, Sarrabere MP, Roux JO, et al. Acute osteoporotic vertebral collapse: Open study on percutaneous injection of acrylic surgical cement in 20 patients. AJR Am J Roentgenol. 1999; 173:1685–90.
Article
18. Laredo JD, Hamz B. Complication of percutaneous vertebroplasty and their prevention. Skeletal Radiol. 2004; 33:493–505.
Article
Full Text Links
  • JKSS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr