1. Lundberg GD. Acting on significant laboratory results. JAMA. 1981. 245:1762–1763.
Article
2. Lundberg GD. How clinicians should use the diagnostic laboratory in a changing medical world. Clin Chim Acta. 1999. 280:3–11.
Article
3. Laposata M, Dighe A. "Pre-pre" and "post-post" analytical error: high-incidence patient safety hazards involving the clinical laboratory. Clin Chem Lab Med. 2007. 45:712–719.
Article
4. Stroobants AK, Goldschmidt HM, Plebani M. Error budget calculations in laboratory medicine: linking the concepts of biological variation and allowable medical errors. Clin Chim Acta. 2003. 333:169–176.
Article
5. Gandhi TK, Kachalia A, Thomas EJ, Puopolo AL, Yoon C, Brennan TA, et al. Missed and delayed diagnoses in the ambulatory setting: a study of closed malpractice claims. Ann Intern Med. 2006. 145:488–496.
Article
6. Hickner J, Graham DG, Elder NC, Brandt E, Emsermann CB, Dovey S, et al. Testing process errors and their harms and consequences reported from family medicine practices: a study of the American Academy of Family Physicians National Research Network. Qual Saf Health Care. 2008. 17:194–200.
Article
7. Kachalia A, Gandhi TK, Puopolo AL, Yoon C, Thomas EJ, Griffey R, et al. Missed and delayed diagnoses in the emergency department: a study of closed malpractice claims from 4 liability insurers. Ann Emerg Med. 2007. 49:196–205.
Article
8. Wahls TL, Cram PM. The frequency of missed test results and associated treatment delays in a highly computerized health system. BMC Fam Pract. 2007. 8:32.
Article
9. Leape LL. Errors in medicine. Clin Chim Acta. 2009. 404:2–5.
Article
10. Weissman JS, Rothschild JM, Bendavid E, Sprivulis P, Cook EF, Evans RS, et al. Hospital workload and adverse events. Med Care. 2007. 45:448–455.
Article
11. Leape LL. Striving for perfection. Clin Chem. 2002. 48:1871–1872.
Article
12. Kalra J. Medical errors: impact on clinical laboratories and other critical areas. Clin Biochem. 2004. 37:1052–1062.
Article
13. Nevalainen D, Berte L, Kraft C, Leigh E, Picaso L, Morgan T. Evaluating laboratory performance on quality indicators with the six sigma scale. Arch Pathol Lab Med. 2000. 124:516–519.
Article
14. Plebani M. Exploring the iceberg of errors in laboratory medicine. Clin Chim Acta. 2009. 404:16–23.
Article
15. Astion ML, Shojania KG, Hamill TR, Kim S, Ng VL. Classifying laboratory incident reports to identify problems that jeopardize patient safety. Am J Clin Pathol. 2003. 120:18–26.
Article
16. Kalra J. Medical errors: overcoming the challenges. Clin Biochem. 2004. 37:1063–1071.
Article
17. Kalra J. Medical errors: an introduction to concepts. Clin Biochem. 2004. 37:1043–1051.
Article
18. Rattan A, Lippi G. Frequency and type of preanalytical errors in a laboratory medicine department in India. Clin Chem Lab Med. 2008. 46:1657–1659.
Article
19. Bonini P, Plebani M, Ceriotti F, Rubboli F. Errors in laboratory medicine. Clin Chem. 2002. 48:691–698.
Article
20. Carraro P, Plebani M. Errors in a stat laboratory: types and frequencies 10 years later. Clin Chem. 2007. 53:1338–1342.
Article
21. Frankel A, Gandhi TK, Bates DW. Improving patient safety across a large integrated health care delivery system. Int J Qual Health Care. 2003. 15:Suppl 1. i31–i40.
Article
22. Plebani M. The detection and prevention of errors in laboratory medicine. Ann Clin Biochem. 2010. 47:101–110.
Article
23. Lippi G, Plebani M. The importance of incident reporting in laboratory diagnostics. Scand J Clin Lab Invest. 2009. 69:811–813.
Article
24. Lippi G, Guidi GC. Risk management in the preanalytical phase of laboratory testing. Clin Chem Lab Med. 2007. 45:720–727.
Article
25. Wagar EA, Yuan S. The laboratory and patient safety. Clin Lab Med. 2007. 27:909–930.
Article
26. Plebani M, Carraro P. Mistakes in a stat laboratory: types and frequency. Clin Chem. 1997. 43:1348–1351.
Article
27. Hofgärtner WT, Tait JF. Frequency of problems during clinical molecular-genetic testing. Am J Clin Pathol. 1999. 112:14–21.
Article
28. O'Kane M. The reporting, classification and grading of quality failures in the medical laboratory. Clin Chim Acta. 2009. 404:28–31.
29. O'Kane MJ, Lynch PL, McGowan N. The development of a system for the reporting, classification and grading of quality failures in the clinical biochemistry laboratory. Ann Clin Biochem. 2008. 45:129–134.
30. International Organization for Standardisation. ISO/TS 22367: Medical laboratories - reduction of error through risk management and continual improvement. 2008. Geneva: International Organization for Standardisation.
31. Plebani M. Errors in clinical laboratories or errors in laboratory medicine? Clin Chem Lab Med. 2006. 44:750–759.
Article
32. Leape LL, Brennan TA, Laird N, Lawthers AG, Localio AR, Barnes BA, et al. The nature of adverse events in hospitalized patients. Results of the Harvard Medical Practice Study II. N Engl J Med. 1991. 324:377–384.
33. Brennan TA, Leape LL, Laird NM, Hebert L, Localio AR, Lawthers AG, et al. Incidence of adverse events and negligence in hospitalized patients. Results of the Harvard Medical Practice Study I. N Engl J Med. 1991. 324:370–376.
34. Vincent C, Neale G, Woloshynowych M. Adverse events in British hospitals: preliminary retrospective record review. BMJ. 2001. 322:517–519.
Article
35. Wilson RM, Runciman WB, Gibberd RW, Harrison BT, Newby L, Hamilton JD. The quality in Australian health care study. Med J Aust. 1995. 163:458–471.
Article
36. Aspden P, Corrigan JM, editors. Patient safety: achieving a new standard for care. 2004. Washington DC: National Academy Press.
37. Kohn LT, Corrigan JM, editors. To err is human: building a safer health system. 2000. Washington DC: National Academy Press.
38. Institute of Medicine. Crossing the quality chasm: a new health system for the 21st century. 2001. Washington DC: National Academy Press.
39. Department of Health. An organisation with a memory: report of an expert group on learning from adverse events in the NHS chaired by the Chief Medical Officer. 2000. London: The Stationery Office.
40. National Quality Forum. Preferred practices for measuring and reporting patient safety and communication in laboratory medicine: a consensus report. 2009. Washington DC: National Quality Forum.
42. Lippi G, Salvagno GL, Montagnana M, Franchini M, Guidi GC. Phlebotomy issues and quality improvement in results of laboratory testing. Clin Lab. 2006. 52:217–230.
43. Lippi G, Fostini R, Guidi GC. Quality improvement in laboratory medicine: extra-analytical issues. Clin Lab Med. 2008. 28:285–294.
Article
44. Linden JV, Wagner K, Voytovich AE, Sheehan J. Transfusion errors in New York State: an analysis of 10 years' experience. Transfusion. 2000. 40:1207–1213.
Article
45. Howanitz PJ, Renner SW, Walsh MK. Continuous wristband monitoring over 2 years decreases identification errors: a college of American pathologists Q-tracks study. Arch Pathol Lab Med. 2002. 126:809–815.
46. Mercuriali F, Inghilleri G, Colotti MT, Farè M, Biffi E, Vinci A, et al. Bedside transfusion errors: analysis of 2 years' use of a system to monitor and prevent transfusion errors. Vox Sang. 1996. 70:16–20.
Article
47. Williamson LM, Lowe S, Love EM, Cohen H, Soldan K, McClelland DB, et al. Serious hazards of transfusion (SHOT) initiative: analysis of the first two annual reports. BMJ. 1999. 319:16–19.
Article
48. Valenstein PN, Sirota RL. Identification errors in pathology and laboratory medicine. Clin Lab Med. 2004. 24:979–996.
Article
49. Linden JV, Paul B, Dressler KP. A report of 104 transfusion errors in New York State. Transfusion. 1992. 32:601–606.
Article
50. Lippi G, Bassi A, Brocco G, Montagnana M, Salvagno GL, Guidi GC. Preanalytic error tracking in a laboratory medicine department: results of a 1-year experience. Clin Chem. 2006. 52:1442–1443.
Article
51. Valenstein PN, Raab SS, Walsh MK. Identification errors involving clinical laboratories: a college of American pathologists Q-Probes study of patient and specimen identification errors at 120 institutions. Arch Pathol Lab Med. 2006. 130:1106–1113.
Article
52. Kost GJ, Hale KN. Global trends in critical values practices and their harmonization. Clin Chem Lab Med. 2011. 49:167–176.
Article
53. Emancipator K. American Society of Clinical Pathologists. Critical values: ASCP practice parameter. Am J Clin Pathol. 1997. 108:247–253.
54. Dighe AS, Rao A, Coakley AB, Lewandrowski KB. Analysis of laboratory critical value reporting at a large academic medical center. Am J Clin Pathol. 2006. 125:758–764.
Article
55. Tate KE, Gardner RM. Computers, quality, and the clinical laboratory: a look at critical value reporting. Proc Annu Symp Comput Appl Med Care. 1993. 193–197.
56. Shahangian S, Snyder SR. Laboratory medicine quality indicators: a review of the literature. Am J Clin Pathol. 2009. 131:418–431.
57. Howanitz PJ, Steindel SJ, Heard NV. Laboratory critical values policies and procedures: a college of American pathologists Q-probes study in 623 institutions. Arch Pathol Lab Med. 2002. 126:663–669.
58. Joint Commision International. JCI accreditation hospital survey process guide. 2010. 4th ed. Oakbrook Terrace, IL: Joint Commission International.
59. College of Americal Pathologists. Laboratory accreditation program. Laboratory general checklist. 2010. Northfield, IL: College of American Pathologists.
60. International Organization for Standardization. ISO 15189: Medical laboratories - particular requirements for quality and competence. 2007. Geneva: International Organization for Standardization.
61. Don-Wauchope AC, Chetty VT. Laboratory defined critical value limits: how do hospital physicians perceive laboratory based critical values? Clin Biochem. 2009. 42:766–770.
Article
62. Cooper G, DeJonge N, Ehrmeyer S, Yundt-Pacheco J, Jansen R, Ricós C, et al. Collective opinion paper on findings of the 2010 convocation of experts on laboratory quality. Clin Chem Lab Med. 2011. 49:793–802.
Article
63. Clinical and Laboratory Standards Institute. EP18-A2: Risk management techniques to identify and control laboratory error sources. Approver guideline. 2009. 2nd ed. Wayne, PA: Clinical and Laboratory Standards Institute.
64. Clinical and Laboratory Standards Institute. EP23-P: Laboratory quality control based on risk management. 2010. Wayne, PA: Clinical and Laboratory Standards Institute.
65. Clinical and Laboratory Standards Institute. GP32-A: Management of non-conforming laboratory event. 2007. Wayne, PA: Clinical and Laboratory Standards Institute.
66. Reason J. Human error: models and management. BMJ. 2000. 320:768–770.
Article
67. Lippi G, Banfi G, Buttarello M, Ceriotti F, Daves M, Dolci A, et al. Recommendations for detection and management of unsuitable samples in clinical laboratories. Clin Chem Lab Med. 2007. 45:728–736.
Article
74. Livesey JH, Ellis MJ, Evans MJ. Pre-analytical requirements. Clin Biochem Rev. 2008. 29:Suppl 1. S11–S15.
75. Alsina MJ, Alvarez V, Barba N, Bullich S, Cortés M, Escoda I, et al. Pre-analytical quality control program - an overview of results (2001-2005 summary). Clin Chem Lab Med. 2008. 46:849–854.
Article
76. Khoury M, Burnett L, Mackay MA. Error rates in Australian chemical pathology laboratories. Med J Aust. 1996. 165:128–130.
Article
77. Lippi G, Chance JJ, Church S, Dazzi P, Fontana R, Giavarina D, et al. Preanalytical quality improvement: from dream to reality. Clin Chem Lab Med. 2011. 49:1113–1126.
Article
78. Llopis MA, Trujillo G, Llovet MI, Tarrés E, Ibarz M, Biosca C, et al. Quality indicators and specifications for key analytical-extranalytical processes in the clinical laboratory. Five years' experience using the Six Sigma concept. Clin Chem Lab Med. 2011. 49:463–470.
Article
79. Sciacovelli L, Plebani M. The IFCC working group on laboratory errors and patient safety. Clin Chim Acta. 2009. 404:79–85.
Article
80. Plebani M, Sciacovelli L, Lippi G. Quality indicators for laboratory diagnostics: consensus is needed. Ann Clin Biochem. 2011. 48:479.
Article
81. Sciacovelli L, O'Kane M, Skaik YA, Caciagli P, Pellegrini C, Da Rin G, et al. Quality indicators in laboratory medicine: from theory to practice. Preliminary data from the IFCC working group project "Laboratory Errors and Patient Safety". Clin Chem Lab Med. 2011. 49:835–844.
82. Wagar EA, Stankovic AK, Wilkinson DS, Walsh M, Souers RJ. Assessment monitoring of laboratory critical values: a college of American pathologists Q-tracks study of 180 institutions. Arch Pathol Lab Med. 2007. 131:44–49.
Article
83. Piva E, Sciacovelli L, Zaninotto M, Laposata M, Plebani M. Evaluation of effectiveness of a computerized notification system for reporting critical values. Am J Clin Pathol. 2009. 131:432–441.
Article
84. Piva E, Sciacovelli L, Laposata M, Plebani M. Assessment of critical values policies in Italian institutions: comparison with the US situation. Clin Chem Lab Med. 2010. 48:461–468.
Article
85. Barth JH. Clinical quality indicators in laboratory medicine: a survey of current practice in the UK. Ann Clin Biochem. 2011. 48:238–240.
Article
86. Plebani M, Sciacovelli L, Lippi G. Quality indicators for laboratory diagnostics: consensus is needed. Ann Clin Biochem. 2011. 48:479.
Article
87. Lippi G, Guidi GC, Mattiuzzi C, Plebani M. Preanalytical variability: the dark side of the moon in laboratory testing. Clin Chem Lab Med. 2006. 44:358–365.
Article
88. Howanitz PJ. Errors in laboratory medicine: practical lessons to improve patient safety. Arch Pathol Lab Med. 2005. 129:1252–1261.
Article
89. Hawkins RC. Laboratory turnaround time. Clin Biochem Rev. 2007. 28:179–194.
90. Howanitz PJ, Cembrowski GS, Steindel SJ, Long TA. Physician goals and laboratory test turnaround times. A college of American pathologists Q-probes study of 2763 clinicians and 722 institutions. Arch Pathol Lab Med. 1993. 117:22–28.
91. Steindel SJ, Howanitz PJ. Physician satisfaction and emergency department laboratory test turnaround time. Arch Pathol Lab Med. 2001. 125:863–871.
Article
92. Valenstein P, Schifman RB. Duplicate laboratory orders: a college of American pathologists Q-Probes study of thyrotropin requests in 502 institutions. Arch Pathol Lab Med. 1996. 120:917–921.
93. Hawkins RC. Potentially inappropriate repeat laboratory testing in inpatients. Clin Chem. 2006. 52:784–785.
Article
94. Bates DW, Kuperman GJ, Rittenberg E, Teich JM, Fiskio J, Ma'luf N, et al. A randomized trial of a computer-based intervention to reduce utilization of redundant laboratory tests. Am J Med. 1999. 106:144–150.
Article
95. Bates DW, Boyle DL, Rittenberg E, Kuperman GJ, Ma'Luf N, Menkin V, et al. What proportion of common diagnostic tests appear redundant? Am J Med. 1998. 104:361–368.
Article
96. Guidi GC, Lippi G, Solero GP, Poli G, Plebani M. Managing transferability of laboratory data. Clin Chim Acta. 2006. 374:57–62.
Article
97. Plebani M, Ceriotti F, Messeri G, Ottomano C, Pansini N, Bonini P. Laboratory network of excellence: enhancing patient safety and service effectiveness. Clin Chem Lab Med. 2006. 44:150–160.
Article
98. Overhage JM, Tierney WM, Zhou XH, McDonald CJ. A randomized trial of "corollary orders" to prevent errors of omission. J Am Med Inform Assoc. 1997. 4:364–375.
Article
99. Smith BJ, McNeely MD. The influence of an expert system for test ordering and interpretation on laboratory investigations. Clin Chem. 1999. 45:1168–1175.
Article
100. Poley MJ, Edelenbos KI, Mosseveld M, van Wijk MA, de Bakker DH, van der Lei J, et al. Cost consequences of implementing an electronic decision support system for ordering laboratory tests in primary care: evidence from a controlled prospective study in the Netherlands. Clin Chem. 2007. 53:213–219.
Article
101. Plebani M. Appropriateness in programs for continuous quality improvement in clinical laboratories. Clin Chim Acta. 2003. 333:131–139.
Article