J Korean Soc Med Ultrasound.  1999 Dec;18(4):335-339.

Usefullness of Ultrasonography in Diagnosis and Postreduction Evaluation of Nasal Bone Fractures

Affiliations
  • 1Department of Diagnostic Radiology, College of Medicine, Chosun University, Seoul National University College of Medicine.
  • 2Department of Plastic Surgery, College of Medicine, Chosun University.

Abstract

PURPPOSE: To evaluate the usefulness of high frequency ultrasonography in the diagnosis and postreduction evaluation of nasal fracture.
MATERIALS AND METHODS
High frequency ultrasonoqraphy examination was performed with 10MHz linear scanner in 18 patients with nasal injury (mean age : 24 years). Sonographic findings are compared with radiographic findings and CT findings.
RESULTS
In 14 patients, high frequency ultrasonography revealed the nature and location of the fracture clearly. High frequency ultrasonography can also provide detailed information about the postreduction condition of the opposed bone fragments. In 14 patients, CT scan and ultrasound were consecutive performed, and the results were the same as site and shape of fractures.
CONCLUSION
High frequency ultrasonography is a useful method in detection of nasal fracture and postreduction evaluation .


MeSH Terms

Diagnosis*
Humans
Nasal Bone*
Tomography, X-Ray Computed
Ultrasonography*