Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

PUBLICATION DATE

38 results
Display

Preliminary Report of Carotid Artery Stenting Using a Tapered Stent

Jeong CW, Kim DH, Ahn SH, Kim DU, Hong SJ, Kim YS, Byun JN, Oh JH

PURPOSE: To analyze the results of carotid artery stenting using a tapered stent and to evaluate the effectiveness of the tapered stent compared to previously reported studies using non-tapered stents. MATERIALS...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Percutaneous Fenestration and Stent Placement for Aortic Dissection that Relieved Occluded Infrarenal Abdominal Aortic Flow: A Case Report

Cho EM, Byun JN, Kim DH, Kim YJ

Here we report a case of infrarenal abdominal aortic occlusion secondary to Stanford type A acute aortic dissection, which was successfully treated with percutaneous fenestration and aortic stent placement. Adequate...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Usefulness of Ultrasound in the Evaluation of Morphologic Change of a Cirrhotic Liver During Respiration

Byun JN, Kim DH, Suk EH

  • KMID: 1454371
  • J Korean Soc Ultrasound Med.
  • 2010 Dec;29(4):233-239.
PURPOSE: This study was designed to determine whether transabdominal ultrasound can detect different hepatic stiffness between patients with cirrhosis and control subjects. MATERIALS AND METHODS: Sevent-three patients (Child-Pugh class A stage)...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Cardiac MRI and Transthoracic Echocardiography of Left Ventricular Myocardial Noncompaction in A Patient with Congestive Heart Failure: A Case Report

Cho EM, Byun JN, Kim DH

We report a case of a 38-year-old male presenting with new-onset dyspnea, that was diagnosed as left ventricular noncompaction by transthoracic echocardiographic and cardiac MR. The tests revealed left ventricularsystolic...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Renal Hypoperfusion Associated with Splenorenal Shunts in Liver Cirrhosis

Byun JN, Kim DH, Kang SG

PURPOSE: To determine whether spontaneous a splenorenal shunt can be used as an imaging predictor of early renal hemodynamic changes in patients with cirrhosis. MATERIALS AND METHODS: The study included 82...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Duodenal Obstruction and Acquired Gastroduodenal Fistula Caused by Magnets: A Case Report

Kim IJ, Kim DH, Byun JN, Lim HG

Foreign body ingestion in children is commonly encountered and this usually resolves spontaneously. Single magnet ingestion usually does not need additional medical treatment. However, multiple magnets can attract each other...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Assessment of Left Ventricular Function after Mitral Valvular Replacement Using Multidetector Row Computed Tomography: Initial Experience

Kim DH, Byun JN, Ryu SW, Choi SI

PURPOSE: To assess the usefulness of cardiac MDCT for the evaluation of cardiac function and morphology of mitral valve replacement (MVR) with or without subvalvular preservation. MATERIALS AND METHODS: Sixteen patients...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Case of Rupture of a Renal Artery Aneurysm in Polyarteritis Nodosa which is predicted early in Emergency Department

Kim SP, Sun KH, Cho SH, Cho NS, Byun JN

  • KMID: 2331777
  • J Korean Soc Emerg Med.
  • 2007 Aug;18(4):351-354.
Polyarteritis nodosa (PAN) is a necrotizing angitis that predominantly affects small-and medium-sized arteries in which microaneurysm or occlusion of the visceral arteries can be seen by arteriography. Patients with PAN...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Collecting Duct Carcinoma of the Kidney Mimicking Invasive Transitional Cell Carcinoma: A Case Report

Byun JN, Lim HG, Lim SC

  • KMID: 1512108
  • J Korean Soc Ultrasound Med.
  • 2007 Jun;26(2):99-103.
Approximately 100 cases of collecting duct carcinoma have been reported in the medical literature. We herein report on a case of collecting duct carcinoma of the kidney in a 75-year-old...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Can the Splenic Artery Resistive Index Be an Ancillary Sign on Ultrasound for the Differentiation of Alcoholic Cirrhosis from Hepatitis B-virus Related Cirrhosis?

Byun JN, Kim DH

  • KMID: 1512103
  • J Korean Soc Ultrasound Med.
  • 2007 Jun;26(2):69-75.
PURPOSE: We wanted to assess the usefulness of the splenic artery resistive index (RIS) for differentiating between alcoholic cirrhosis (AC) and hepatitis B-virus related cirrhosis (VC). MATERIALS AND METHODS: A total...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Various Ocular MR Imagings in a Mouse Implanted with a New Cell Line of Retinoblastoma and the Correlation with the Pathology: Preliminary Study

Kim DH, Kim IJ, Yang JH, Byun JN, Kim JH, Yu YS, Lee BJ

PURPOSE: We wanted to show various MR and correlated pathologic images of retinoblastoma in nude mousewith a new human retinoblastom cell line (SNUOT-Rb1), which was inoculated into the intravitreous cavity. MATERIALS...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Value of Renal Artery Resistive Indices: Association with Esophageal Variceal Bleeding in Patients with Alcoholic Cirrhosis

Byun JN, Kim DH

PURPOSE: To determine whether resistive indices of the renal artery (RIR) or the splenic artery (RIS) can be used as predictors of bleeding in patients with alcoholic liver cirrhosis. MATERIALS AND...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Occlusive Myocardial Infarction: Cardiac CT Perfusion in a Rat Model

Oh HW, Kim DH, Byun JN, Kim YS

PURPOSE: To test whether cardiac multidetector CT (MDCT) perfusion imaging can accurately delineate an irreversibly damaged myocardium in animals with an occlusive myocardial infarction. MATERIALS AND METHODS: In 16 rats, the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Gossypiboma in the Abdomen: A Case Report

Kim DH, Lim HG, Byun JN, Kim DH, Lim SC

  • KMID: 1302372
  • J Korean Soc Ultrasound Med.
  • 2007 Mar;26(1):21-24.
Gossypiboma is retained surgical sponge or swab. We experienced a case of gossypiboma resulting from a retained surgical sponge, which had been left in intraperitoneal cavity for 4 years after...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Catastrophic Primary Antiphospholipid Syndrome

Kim DH, Byun JN, Ryu SW

Catastrophic antiphospholipid syndrome (CAPLS) was diagnosed in a 64-year-old male who was admitted to our hospital with dyspnea. The clinical and radiological examinations showed pulmonary thromboembolism, and so thromboembolectomy was...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Usefulness of Three Dimensional Reconstructive Images for Thoracic Trauma Induced Fractures

Koh KH, Kim DH, Kim YS, Byun JN

PURPOSE: We wanted to evaluate the usefulness of three-dimensional reconstructive images using multidetector computed tomography (MDCT) for thoracic traumatic patients visiting emergency room. MATERIALS AND METHODS: 76 patients with fractures of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Rupture of Popliteal Arterial Aneurysm due to Salmonella Infection

Kim DH, Oh HW, Kim DH, Byun JN

We report here on a case of popliteal aneurysm and rupture that occurred over a 10-day period and this was all secondary to salmonella infection. Computed tomography (CT) angiography of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Cystic Lymphangioma Involving the Mesentery and the Retroperitoneum: A Case Report

Kim DH, Byun JN, Jang JY

Cystic lymphangioma is uncommon angiomatous tumor that mainly occurs in the neck. Less than 1% of these tumors affect the mesentery, retroperitoneum and greater omentum. In particular, the cystic lymphangioma...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Endovascular Treatment of Arteriovenous Fistula with Pseudoaneurysm at Popliteal Fossa Using a PTFE Stent-graft: A Case Report

Choi JY, Kim DH, Oh HW, Jang JH, Oh JH, Kim YS, Byun JN, Kim YC

We report the successful treatment of a postoperative pseudoaneurysm of a popliteal artery, which was associated with an arteriovenous fistula to the popliteal vein using an endovascular placement of a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Radiofrequency Ablation of the Gastrointestinal Tract with a Stent-Like Electrode: Experimental Study

Byun JN, Kang SG, Choi JY, Kim DH, Lee JM, Kim YC, Ki KH, Lee CG

OBJECTIVE: To assess the technical feasibility of a newly designed stent-like electrode in rabbits. MATERIALS AND METHODS: A stent-like electrode was knitted from a single thread of nitinol wire and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2022 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr