Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

451 results
Display

Effect of surface treatments and universal adhesive application on the microshear bond strength of CAD/CAM materials

Şişmanoğlu S, Gürcan AT, Yıldırım-Bilmez Z, Turunç-Oğuzman R, Gümüştaş B

PURPOSE: The aim of this study was to evaluate the microshear bond strength (µSBS) of four computer-aided design/computer-aided manufacturing (CAD/CAM) blocks repaired with composite resin using three different surface treatment...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Retinal Toxicity Following the Injection Ganciclovir into Silicone Oil-filled Eye to Treat Acute Retinal Necrosis

Jo YJ, Choi SK, Park SH, Lee JJ, Lee JE, Park SW

PURPOSE: To report a case of retinal toxicity after an intravitreal ganciclovir injection to treat acute retinal necrosis in an eye filled with silicone oil. CASE SUMMARY: A 56-year-old male presented...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Novel Dressing Method Using a Silicone Sheet to Maintain Distant Abdominal Flaps after Reconstruction of Finger Skin Defects

Kang JK, Lee JS, Shin MS, Yun BM

The distant abdominal flap has long been used in hand reconstruction due to its stability and minimal complications at the donor site. After the distant abdominal flap is performed, the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A novel technique for placing titanium mesh with porous polyethylene via the endoscopic transnasal approach into the orbit for medial orbital wall fractures

Bae SH, Jeong DK, Go JY, Park H, Kim JH, Lee JW, Kang T

BACKGROUND: The endoscopic transnasal approach is widely used for reconstructing the medial orbital wall by filling it with a silicone sheet or Merocel, but this technique has the disadvantage of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of marginal and internal discrepancies of zirconia crowns fabricated by various digital scan methods

In HS, Cho HW, Jung JH, Kim JM, Kim YL

In this study, marginal and internal discrepancies of zirconia crowns fabricated with the CAD/CAM (computer aided design - computer aided manufacturing) system were compared. Digital impressions were obtained using model...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Do Various Respirator Models Fit the Workers in the Norwegian Smelting Industry?

Foereland , Robertsen , Hegseth MN

BACKGROUND: Respirator fit testing is a method to assess if the respirator provides an adequate face seal for the worker. METHODS: Workers from four Norwegian smelters were invited to participate in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of surface treatments on the bond strength of indirect resin composite to resin matrix ceramics

Çelik E, Şahin SC, Dede DO

PURPOSE: The purpose of this study was to evaluate the shear bond strength (SBS) of an indirect resin composite (IRC) to the various resin matrix ceramic (RMC) blocks using different...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Color alterations of a PMMA resin for fixed interim prostheses reinforced with silica nanoparticles

Kotanidis , Kontonasaki E, Koidis P

PURPOSE: The aim of the present study was to evaluate the color changes of an autopolymerizing PMMA resin used for interim fixed restorations, reinforced with SiO2 nanoparticles. MATERIALS AND METHODS: Silica...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Bone Morphogenetic Protein 2-Conjugated Silica Particles Enhanced Early Osteogenic Differentiation of Adipose Stem Cells on the Polycaprolactone Scaffold

Kim KJ, Choi MS, Shim JH, Rhie JW

BACKGROUND: Silica particles (SPs) induce cell proliferation and osteogenic differentiation. We reported that SPs in the scaffold induced early stage osteogenic differentiation. METHODS: A polycaprolactone (PCL) scaffold was fabricated with a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fluid Dynamics of Small Diameter Tubes Used in Membrane-tube Type Glaucoma Shunt Devices

Han JC, Hwang YH, Ahn BH

PURPOSE: To investigate the outflow characteristics of silicone tubes with intraluminal stents used in membrane-tube (MT) type glaucoma shunt devices. METHODS: The silicone tubes used in MicroMT (internal diameter of 100...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Desmoid-Type Fibromatosis Associated with Silicone Breast Implants

Park JS, Lee SE, Choi JH

Desmoid-type fibromatosis (extra-abdominal desmoid tumor) arising in the breast is a rare benign disease entity, accounting for 0.2% of all breast tumors. The etiology of mammary fibromatosis is unknown, but...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods

Jeong SJ, Cho HW, Jung JH, Kim JM, Kim YL

PURPOSE: The purpose of the present study was to compare the accuracy of four different metal copings fabricated by CAD/CAM technology and to evaluate clinical effectiveness. MATERIALS AND METHODS: Composite resin...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Utilizing a Previous Silicone Band Track in Recurred Retinal Detachment

Kim Y, Choi KS

PURPOSE: We report a case of utilizing a previous silicone band track in the reoperation of scleral encircling. CASE SUMMARY: An 8-year-old male presented with rhegmatogenous retinal detachment in the right...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical Outcomes of Nasolacrimal Probing and Silicone Intubation in Patients with Congenital Nasolacrimal Duct Obstruction

Ahn SH, Lee TE, You IC, Cho NC, Ahn M

PURPOSE: To investigate the efficacy and factors affecting the success rates of nasolacrimal probing and silicone intubation (SI) in patients with congenital nasolacrimal duct obstruction (CNLDO). METHODS: We retrospectively reviewed the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A simple and effective method for addition silicone impression disinfection

Azevedo MJ, Correia I, Portela A, Sampaio-Maia B

PURPOSE: Although dental impression disinfection is determinant to reduce the cross-infection risk, some studies have shown that, in real practice, the disinfection procedures vary considerably. Thus, the aim of this...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Friction underwear for ease of pulling down in elderly patients with overactive bladder: A prospective randomized control trial

You JH, Shin YS, Ko MH, Jeon EJ, You H, Park JK

PURPOSE: Friction underwear was developed by adding small silicon dots in front of the underwear to decrease the time for pulling down underwear in elderly patients with urge incontinence. We...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Differentiation Capacity of Monocyte-Derived Multipotential Cells on Nanocomposite Poly(e-caprolactone)-Based Thin Films

Koliakou I, Gounari E, Nerantzaki M, Pavlidou E, Bikiaris D, Kaloyianni M, Koliakos G

BACKGROUND: Lonocyte-derived multipotential cells (MOMCs) include progenitors capable of differentiation into multiple cell lineages and thus represent an ideal autologous transplantable cell source for regenerative medicine. In this study, we...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effects of primers on the microtensile bond strength of resin cements to cobalt-chromium alloy

Jung HT, Campana SA, Park JH, Shin JH, Lee JY

PURPOSE: The aim of this study is to evaluate the effects of various primers on the microtensile bond strength (µTBS) of resin cements to cobalt-chromium (Co-Cr) dental casting alloy. MATERIALS AND...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Physical characteristics of ceramic/glass-polymer based CAD/CAM materials: Effect of finishing and polishing techniques

Ekici MA, Egilmez F, Cekic-Nagas I, Ergun G

PURPOSE: The aim of this study was to compare the effect of different finishing and polishing techniques on water absorption, water solubility, and microhardness of ceramic or glass-polymer based computer-aided...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Analysis of subclinical infections and biofilm formation in cases of capsular contracture after silicone augmentation rhinoplasty: Prevalence and microbiological study

Jirawatnotai S, Mahachitsattaya B

BACKGROUND: Implant-related deformities in aesthetic rhinoplasty are a major problem for rhinoplasty surgeons. Capsular contracture is believed to be the pathological cause of delayed contour deformities, comparable to breast implant-related...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2021 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr