Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

PUBLICATION DATE

15 results
Display

Detection of root perforations using conventional and digital intraoral radiography, multidetector computed tomography and cone beam computed tomography

Shokri A, Eskandarloo A, Noruzi-Gangachin M, Khajeh S

OBJECTIVES: This study aimed to compare the accuracy of conventional intraoral (CI) radiography, photostimulable phosphor (PSP) radiography, cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) for detection of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Factors Associated With Failure of Health System Reform: A Systematic Review and Meta-synthesis

Bayat M, Kashkalani T, Khodadost M, Shokri A, Fattahi H, Ghasemi Seproo F, Younesi F, khalilnezhad R

Objectives: The health system reform process is highly political and controversial, and in most cases, it fails to realize its intended goals. This study was conducted to synthesize factors underlying...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Prevalence and characteristics of pneumatized articular tubercle: First large series in Iranian people

Shokri A, Noruzi-Gangachin M, Baharvand , Mortazavi

PURPOSE: This study was performed to determine the prevalence and characteristics of pneumatized articular tubercle or eminence among a defined group of Iranian people. MATERIALS AND METHODS: Digital panoramic radiographs of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of data mining algorithms for sex determination based on mastoid process measurements using cone-beam computed tomography

Farhadian M, Salemi F, Shokri A, Safi Y, Rahimpanah S

Purpose: The mastoid region is ideal for studying sexual dimorphism due to its anatomical position at the base of the skull. This study aimed to determine sex in the Iranian...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Position of the hyoid bone and its correlation with airway dimensions in different classes of skeletal malocclusion using cone-beam computed tomography

Shokri A, Mollabashi V, Zahedi F, Tapak L

Purpose: This study investigated the position of the hyoid bone and its relationship with airway dimensions in different skeletal malocclusion classes using cone-beam computed tomography (CBCT). Materials and Methods: CBCT scans...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Magnetic resonance imaging study of incidental findings in the paranasal sinuses and ostiomeatal complex

Yousefi F, Mollabashi M, Shokri A, Tavakoli E, Farhadian M, Tavakoli A

Purpose This study aimed to assess incidental abnormal findings in the paranasal sinuses and anatomical variations of the ostiomeatal complex (OMC) on magnetic resonance imaging (MRI) scans. Materials and Methods MRI scans of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Isolation and Genotyping of Acanthamoeba spp. as Neglected Parasites in North of Iran

Shokri A, Sarvi S, Daryani A, Sharif M

Acanthamoeba, a free-living amoeba, is widely distributed in the environment, water sources, soil, dust, and air. It can cause keratitis in contact lens wearers with poor hygiene and also fatal...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Position of impacted mandibular third molar in different skeletal facial types: First radiographic evaluation in a group of Iranian patients

Shokri A, Mahmoudzadeh M, Baharvand , Mortazavi , Faradmal J, Khajeh S, Yousefi F, Noruzi-Gangachin M

PURPOSE: This study was performed to evaluate the position of impacted mandibular third molars in different skeletal facial types among a group of Iranian patients. MATERIALS AND METHODS: A total of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Correlations between anatomical variations of the nasal cavity and ethmoidal sinuses on cone-beam computed tomography scans

Shokri A, Faradmal M, Hekmat B

PURPOSE: Anatomical variations of the external nasal wall are highly important, since they play a role in obstruction or drainage of the ostiomeatal complex and ventilation and can consequently elevate...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Dehgolan Prospective Cohort Study (DehPCS) on non-communicable diseases in a Kurdish community in the west of Iran

Moradpour F, Ghaderi E, Moradi G, Zarei M, Bolbanabad AM, Piroozi B, Shokri A

The Dehgolan Prospective Cohort Study (DehPCS) was conducted to examine and identify risk factors for the most prevalent non-communicable diseases (NCDs). In addition, in order to examine participants’ health status,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Assessment of the accuracy of laser-scanned models and 3-dimensional rendered cone-beam computed tomographic images compared to digital caliper measurements on plaster casts

Yousefi F, Shokri A, Zahedi F, Farhadian M

Purpose This study investigated the accuracy of laser-scanned models and 3-dimensional (3D) rendered cone-beam computed tomography (CBCT) compared to the gold standard (plaster casts) for linear measurements on dental arches. Materials and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Prevalence of dental anomalies among 7- to 35-year-old people in Hamadan, Iran in 2012-2013 as observed using panoramic radiographs

Shokri A, Poorolajal J, Khajeh S, Faramarzi , Kahnamoui

PURPOSE: This study was performed to evaluate the prevalence of all types and subtypes of dental anomalies among 7- to 35-year-old patients by using panoramic radiographs. MATERIALS AND METHODS: This cross-sectional...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Accuracy of maxillofacial prototypes fabricated by different 3-dimensional printing technologies using multi-slice and cone-beam computed tomography

Yousefi F, Shokri A, Farhadian M, Vafaei F, Forutan F

Purpose This study aimed to compare the accuracy of 3-dimensional (3D) printed models derived from multidetector computed tomography (MDCT) and cone-beam computed tomography (CBCT) systems with different fields of view (FOVs). Materials...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of field-of-view size on gray values derived from cone-beam computed tomography compared with the Hounsfield unit values from multidetector computed tomography scans

Shokri A, Ramezani L, Bidgoli M, Akbarzadeh M, Ghazikhanlu-Sani K, Fallahi-Sichani H

PURPOSE: This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from conebeam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Diagnostic accuracy of cone-beam computed tomography scans with high- and low-resolution modes for the detection of root perforations

Shokri A, Eskandarloo A, Norouzi M, Poorolajal J, Majidi G, Aliyaly A

PURPOSE: This study compared the diagnostic accuracy of cone-beam computed tomography (CBCT) scans obtained with 2 CBCT systems with high- and low-resolution modes for the detection of root perforations in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr