Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

1,239 results
Display

Percutaneous Pulmonary Valve Implantation

Giugno L, Faccini A, Carminati

Percutaneous pulmonary valve implantation (PPVI) is recognized as a feasible and low risk alternative to surgery to treat dysfunctional right ventricular outflow tract (RVOT) in usually pluri-operated patients. Evolving technology...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Three-dimensional-printing Technology in Hip and Pelvic Surgery: Current Landscape

Woo SH, Sung MJ, Park KS, Yoon TR

The use of three-dimensional (3D) printing is becoming more common, including in the field of orthopaedic surgery. There are currently four primary clinical applications for 3D-printing in hip and pelvic...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Attitude and treatment options in implant-supported prosthetics: A survey among a cohort of German dentists

Glücker C, Rauch A, Hahnel S

PURPOSE: The aim of the current study was to analyze treatment concepts of a cohort of German dentists for planning, fabrication, and maintenance of implant-supported fixed and removable restorations. MATERIALS AND...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Implant-assisted removable partial denture using freely removable abutment in a fully edentulous patient: A case report

Oh YK, Jeong CM, Yun MJ, Lee SH, Lee HJ, Huh JB

Implant-Assisted Removable Partial Dentures (IARPDs) treatment is being performed in a fully edentulous patient using implant surveyed prosthesis as an abutment. Implant-supported prosthesis as an abutment of IARPDs is classified...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Full mouth rehabilitation using removable prosthesis of patient with unstable mandible movements: A case report

Sohn DH, Yi YJ, Jo DW

Patients with collapsed occlusal support and unilateral chewing show parafunctional mandibular movements, which can be complicated in older patients. Gothic arch tracing and split cast technique are used to confirm...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fabrication of closed hollow obturator for hard palate defect patient undergone maxillectomy

Jang WH, Lim HP, Yun KD, Park C, Yang HS

Maxillectomy is performed to remove the tumor in the palate, maxillary sinus, buccal mucosa or nasal cavity. The resection range depends on the size and the extent of the tumor...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Success and survival rate of the implant with crestal sinus lift using S-reamer and gel-type graft material: A retrospective study by more 5-years follow check up

Kim JJ, Cho SA

PURPOSE: The purpose of this retrospective study was to evaluate the method using the S-reamer and gel-type graft material by the success rate and survival rate. MATERIALS AND METHODS: Implantation period...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Marginal and internal discrepancy of 3-unit fixed dental prostheses fabricated by subtractive and additive manufacturing

Choi JW

PURPOSE: This study was to evaluate marginal and internal discrepancy of 3-unit fixed dental prostheses (FDP) fabricated by subtractive manufacturing and additive manufacturing. MATERIALS AND METHODS: 3-unit bridge abutments without the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Metallic Artifacts on MR Imaging and Methods for Their Reduction

Choo HJ, Lee SJ, Lee YH

Metallic artifacts on MR imaging are typically induced by differences in magnetic susceptibility between the metallic implant and surrounding tissue. Conventional techniques for metal artifact reduction require MR machines with...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Complete mouth rehabilitation with zirconia fixed partial dentures supported by natural teeth and implants: A case report

An JH, Jung JH, Cho HW

When a maxillary implant-supported fixed prosthesis is planned for anterior partially edentulous region, the degree of atrophy of the residual ridge, prospective location of the implants and inclination of the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Mechanical Complications of Posterior Implant Restorations using CAD/CAM Titanium Customized Abutments: A Retrospective Study

Yang M, Chang JS, Ji W, Kim S

PURPOSE: The purpose of this retrospective study was to evaluate the incidence of mechanical complications of the posterior implant-supported fixed dental prosthesis (p-ISFDP) using computer-aided design and computer-aided manufacturing (CAD/CAM)...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Erratum: Clinical outcomes of a low-cost single-channel myoelectric-interface three-dimensional hand prosthesis

Ku I, Lee GK, Park CY, Lee J, Jeong E

We have noticed two errors in our published paper above. In Fig. 3, the name of “Figure by courtesy of Sanho Yi” should be “Sangho Yi.” In Table 2, the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Association Between Dental Implants and Cognitive Function in Community-dwelling Older Adults in Korea

Ki S, Yun J, Kim J, Lee Y

OBJECTIVES: This study aimed to evaluate the association between dental implants and cognitive function in community-dwelling older adults. METHODS: Data were collected from the baseline survey (2016–2017) of the Korean Frailty...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
3D-Printed Prosthesis Replacement for Limb Salvage after Radical Resection of an Ameloblastoma in the Tibia with 1 Year of Follow Up: A Case Report

Feng D, He J, Zhang C, Wang L, Gu X, Guo Y

Ameloblastoma in the tibia is rare. Limb reconstruction after tumor resection is challenging in terms of selection of the operative method. Here, we report a case of radical resection of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Penile Prosthesis Infection: Myths and Realities

Hebert KJ, Kohler TS

Penile prosthesis infection is the most significant complication following prosthesis implant surgery leading to postoperative morbidity, increased health care costs, and psychological stress for the patient. We aimed to identify...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Color alterations of a PMMA resin for fixed interim prostheses reinforced with silica nanoparticles

Kotanidis , Kontonasaki E, Koidis P

PURPOSE: The aim of the present study was to evaluate the color changes of an autopolymerizing PMMA resin used for interim fixed restorations, reinforced with SiO2 nanoparticles. MATERIALS AND METHODS: Silica...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical outcomes of a low-cost single-channel myoelectric-interface three-dimensional hand prosthesis

Ku I, Lee GK, Park CY, Lee J, Jeong E

BACKGROUND: Prosthetic hands with a myoelectric interface have recently received interest within the broader category of hand prostheses, but their high cost is a major barrier to use. Modern three-dimensional...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Flapless implant placement with digital 3D imaging and planning system in fully edentulous patient: A case report and 5-year follow-up

Shin MS, Paek J

One of the fastest growing segments of implant dentistry is the utilization of computed tomography (CT) scan data and treatment planning software in conjunction with guided surgery for implant reconstruction...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Use of digital scan data for evaluation of edentulous ridge relationship: A case report for removable prosthesis with unilateral cross bite

Kim JH, Kim JE, Park YB, Lee KW

After the teeth were extracted, maxillary and mandibular alveolar ridges show the opposite resorption pattern and as a result, the mandibular arch is enlarged than maxillary arch relatively. In this...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Full mouth rehabilitation of patient with severe dental caries with implant fixed prosthesis fabricated with milling and 3D printing method: A case report

Kim T, Lee JS, Hong SJ, Kim HS, Kwon KR

Passive fit of prosthesis is an essential property of implant supported prosthesis for long term success and minimization of complications. And the property is determined mostly by fabrication procedure. There...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2021 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr