Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

92 results
Display

The Effect of Physical Barriers on Delayed Adjustable Strabismus Surgery

Hwang JM, Chang BL

  • KMID: 2022589
  • J Korean Ophthalmol Soc.
  • 1996 Apr;37(4):675-684.
Delayed reattachment of the muscle to the sclera may be desirable to correct the angle of deviation developed after the surgery of strabismus. In order to know the possible time...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Use of the Polyglactin 910 (Vicryl) 8-0 Sutures in Cataract Extraction and Trabeculectomy Surgery

Rhee SW, Lee KH

  • KMID: 2204636
  • J Korean Ophthalmol Soc.
  • 1978 Mar;19(1):43-47.
The ideal suture for use in ophthalmic surgery is one that is fine yet strong, non-irritant, and non allergic, predictably and reliably absorbed after a suitable period of time, and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
GUIDED BONE REGENERATION OF CRANIAL DEFECTS USING VARIOUS MEMBRANES : AN EXPERIMENTAL STUDY IN RABBITS

Son JH, Kim JN

  • KMID: 2190622
  • J Korean Assoc Oral Maxillofac Surg.
  • 1997 Jul;23(3):474-486.
Various techniques for treatment of large bone defects have been reported, instead of using autogenous bone graft. The author have applied and explored for bone repair with polyglactin 910 mesh...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparative Study of Tissue Response of Various Suture Materials in Rats

Kim JS, Park JB, Lee MS, Herr Y

The purpose of this study is to evaluate histologically the tissue response and resorption of various nonresorbable and resorbable suture materials used for periodontal surgery, using a subcutaneous model on...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Use of Physical Barriers for the Surgical Treatment of Fat Adherence Syndrome: The Effect of Viscoat, Interceed, Polyglactin 910 Mesh and Polytetrafluoroethylene

Hwang JM

  • KMID: 2205216
  • J Korean Ophthalmol Soc.
  • 1997 Jun;38(6):1064-1071.
The fat adherence syndrome is a type of restrictive strabismus resulting from the formation of adherence of orbital tissues to the globe or extraocular muscles in association with violation of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of tensile strength of surgical synthetic absorbable suture materials: an in vitro study

Khiste SV, Ranganath , Nichani AS

PURPOSE: The purpose of this study was to evaluate the tensile strength of surgical synthetic absorbable sutures over a period of 14 days under simulated oral conditions. METHODS: Three suture materials...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Five cases of webbed penis

Kim KD, Lee TY

  • KMID: 1912854
  • Korean J Urol.
  • 1991 Feb;32(1):132-134.
Webbed penis without chordee or hypospadias is uncommon malformation of the genital integument which is repaired easily once the condition is recognized. Examination reveals a web of skin extending between...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Volume Replacement with Polyglactin 910 Mesh for Breast Reconstruction after Endoscopy-Assisted Breast Conserving Surgery for Treating Early Breast Cancer: the Early Results

Lee JH, Hong YI, Jeong JH, Lee JI, Lee JH, Moon HJ, Park JK, Shin H

PURPOSE: We introduce a new technique using a Vicryl(R) mesh made with Polyglactin 910 for breast reconstruction after performing endoscopy-assisted breast conserving surgery. METHODS: From July 2006 to July 2008, we...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fat Preservation Lower Blepharoplasty: Septal Draping Over Inferior Orbital Rim

Lee TJ, Yoon SY

  • KMID: 2203883
  • J Korean Soc Plast Reconstr Surg.
  • 2001 Mar;28(2):100-104.
Although the surgical excision of the fat pad has been the mainstay of the management of lower palpebral bulge in cosmetic blepharoplasty, procedures that depend on fat removal may render...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of 2-Octylcyanoacrylate and Suture with 8-0 Polyglactin for Conjunctival Wound Closure in Rabbits

Ryu WY, Yoo KW

  • KMID: 2337208
  • J Korean Ophthalmol Soc.
  • 2005 May;46(5):896-903.
PURPOSE: To evaluate the clinical efficacy and the histopathologic tolerance of 2-octylcyanoacrylate versus 8-0 polyglactin sutures for conjunctival wound closure in rabbits. METHODS: We performed an experimental study on 16...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Simplified suturing method using Hem-o-lock in two port laparoscopic myomectomy

Kim SH, Choi CH, Kim BG, Bae DS

  • KMID: 2083916
  • Korean J Gynecol Endosc Minim Invasive Surg.
  • 2012 Nov;24(2):59-63.
The hem-o-lock is useful tools for the laparoscopic surgeon. We herein describe a simplified technique for suturing and knotting technique using hem-o-loc. After enucleation of the myoma, uterine parenchymal defect...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Influences of Suture Materials on Corneal Astigmatism After Cataract Surgery

Hoang HR, Kim SH, Lee Y

  • KMID: 2122897
  • J Korean Ophthalmol Soc.
  • 1989 Feb;30(1):19-53.
While advancements in microsurgical technique and suture material have led to meticulous wound closure in cataract surgery, excessive postoperative corneal astigmatism may delay visual recovery and compromise the ultimate optical...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Experimental Strebismus Surgery with Tissel in Rabbit Models

Seong GJ, Kim HB, Koh HJ

  • KMID: 2122978
  • J Korean Ophthalmol Soc.
  • 1991 Jan;32(1):83-88.
We performed experimental surgery with Tisseel in rabbit models, to determine whether Tisseeling can replace the classic suture technique. 30 albino rabbits were divided into two groups-one group was Tisseel...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Tie-Over Dressing Using a Silicone Tube to Graft Deep Wounds

Bektas CI, Kankaya Y, Ozer K, Baris R, Aslan OC, Kocer U

BACKGROUND: The most common cause of skin graft failure is the collection of blood or serous fluid underneath the graft. In our study, we describe the use of silicone tube...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Analysis of Infections Occurring in Breast Cancer Patients after Breast Conserving Surgery Using Mesh

Cho JS, Shin SH, Park JY, Song YJ, Yi JM, Park MH, Yoon JH, Jegal YJ, Yi JS, An SJ, Lim HS

PURPOSE: Breast conserving surgery using mesh can effectively fill the defective space, but there is the risk of infection. METHODS: From June 2007 to August 2010, 243 patients who underwent breast...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of E. coli Infiltration between New Synthetic Absorbable Sutures

Choi HJ, Chae HD

PURPOSE: The proper selection of suture is very important to minimize infection after gastrointestinal anastomosis and closure, which is one of the causes of postoperative complications such as leakage and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Retroperitoneoscopic Partial Nephrectomy in a Horseshoe Kidney

Lee YS, Yu HS, Kim MU, Jang HS, Lee DH, Yeom CD, Hwang JH, Ham WS

  • KMID: 2315408
  • Korean J Urol.
  • 2011 Nov;52(11):795-797.
A 21-year-old woman with a 4 cm enhancing cystic renal mass in the left moiety of a horseshoe kidney was treated through a retroperitoneal laparoscopic approach. The tumor was excised...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Comparative Study of Postoperative Adhesions and HistologicReactions Following Pelvic Surgery by Operative Pelviscopy VersusLaparotomy in the Rabbit

Seo JH, Park HM, Bae DH, Hur M

  • KMID: 2271634
  • Korean J Obstet Gynecol.
  • 1997 Mar;40(3):499-509.
Development of adhesions following pelvic surgery is a leading failure of reconstructive surgery. The aims of this study were to compare the occurrence of adhesions after a standard uterine injury...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Surgical Repair of the Kidney after Blunt Renal Injury Using a Vicryl Mesh an Experimental Study

Kim BW, Chang SK

  • KMID: 1912484
  • Korean J Urol.
  • 1987 Apr;28(2):197-202.
Eighteen experimentally induced blunt and sharp renal injury in rabbits were treated either with an alloplastic renal capsule made of Vicryl mesh or with through and through chromic catgut sutures...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Removal of a Piercing Bar in the Mouth floor by Fluoroscopy: Report of a Case

Kim JW, Jang JY, Jang HS, Cha D, Baek SH

  • KMID: 2328417
  • J Korean Assoc Oral Maxillofac Surg.
  • 2008 Apr;34(2):196-199.
The piercing is increasing in western culture, and has also become gradually popular among Korean teenagers recently However, the accident happens sometimes such as loss of a bar into the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr