Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

84 results
Display

Herniorrhaphy with dacron patch

Jung WK, Lee MH, Kim IS, Hur KB

  • KMID: 1693912
  • J Korean Surg Soc.
  • 1993 Aug;45(2):263-270.
No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Experimental study about dacron graft on cannine aorta

Chung JK, Kwon OH, Hong IK, Kim SJ, Kim ST, Kim YI, Choi JW, Lee KB, Min BK, Kim SC, Hong R, Lee JH

  • KMID: 1698708
  • J Korean Vasc Surg Soc.
  • 1991 Dec;7(1):65-73.
No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Repair of Aortic Periprosthetic Leakage with Pseudoaneurysm: A case report

Kim H, Lee HC, Chung WS, Kim YH, Kang JH

  • KMID: 1878505
  • Korean J Thorac Cardiovasc Surg.
  • 2005 Sep;38(9):637-639.
There are several methods of repairing in aortic periprosthetic leakage after aortic valve replacement. We present a case in which the aortic periprosthetic leakage with pseudoaneurysm was repaired with dacron...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Experience with Transobturator Foramen Bypass Surgery: a Case Report

Joo YS, Park KH

  • KMID: 1473305
  • J Korean Soc Vasc Surg.
  • 2009 Nov;25(2):156-159.
The obturator bypass operation is not a common procedure. In 1963, Shaw and Baue first described performing bypass surgery through the obturator foramen as a technique to deal with infected...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Leriche Syndrome: A case report

Lee WJ, Kim HJ, Shim MC, Song SK, Kwun KB

Leriche syndrome is a chronic disorder mostly in male and is a specific symptom complex due to thrombotic obliteration of the aortic bifurcation as result of an atherosclerotic change. The...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Diastema closure with direct composite: architectural gingival contouring

Kim YH, Cho YB

One of the most challenging task in closing anterior diastema is avoiding "black triangle" between the teeth. This paper reports a case that the closure of diastema in anterior teeth could...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Histopathologic study of Dacron Graft following Experimental Fun-thickness Scleral Resection in Rabbits

Song ER, Choi KY, Yoon BJ

  • KMID: 2123179
  • J Korean Ophthalmol Soc.
  • 1993 Oct;34(10):985-992.
To evaluate the possibility of Dacron patch for artificial sclera. Dacron(polyethylene terephthalate) which is readily available, biocompatable, safe, and inert synthetic material was implanted in the area of full-thickness scleral...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Reoperation of Postinfarction VSD

Ahn JH

  • KMID: 2061915
  • Korean J Thorac Cardiovasc Surg.
  • 1997 May;30(5):528-532.
After early surgical repair of ventricular septal rupture complicated by myocardial infarction, newly developed ventricular septal defects were discovered on the 7th and the 40th postoperative day in 2 cases....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Surgical Treatment of Complete Atrioventricular Septal Defect with Tetralogy of Fallot: Report of one case

Lee JH, Lee KS, Park NH, Choi SY, Park CK, Yoo YS

  • KMID: 1916152
  • Korean J Thorac Cardiovasc Surg.
  • 2002 Jun;35(6):460-462.
We experienced primary repair of complete atrioventricular septal defect with Teralogy of Fallot.The diagnosis was established preoperatively by echocardiography,cardiac catheterization and cardioangiography.Repair was accomplished using cardiopulmonary bypass.Two patch techinque were...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
One Stage Repair of Traumatic Ventricular Septal Defect and Mitral Regurgitation

Lee JW, Song TS, Jae HG, Song MK

  • KMID: 1915419
  • Korean J Thorac Cardiovasc Surg.
  • 1999 Dec;32(12):1131-1134.
After a penetrating thoracic injury early detection of intracardiac injury and early surgical repair when indicated are essential. A case presenting severe respiratory distress two weeks after a penetrating thoracic...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Experimental Scleral Grafting with Dacron Patch

Huh K, Shon TS, Kim HM, Jung HR

  • KMID: 2205007
  • J Korean Ophthalmol Soc.
  • 1992 Dec;33(12):1136-1141.
We conducted experimental studies to evaluate the possibility of Dacron patch for artificial sclera and to gain basic data for practical approach. Forty eyes of twenty rabbits were randomly assigned...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Chronic Midgut Volvulus Due to Movable Pancreas: 1 case report

Kim JT, Roe IH, Kim SJ

  • KMID: 1928845
  • Korean J Gastrointest Endosc.
  • 1992 May;12(1):103-106.
Incomplete fixation of pancreas, which may be associated with a wide mobility of root of SMA, result in chronic midgut volvulus. Movable pancreas is an uncommon form of incomplete intestnal...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Late Non-Anastomotic Rupture of a Bifurcated Dacron Aortic Graft Treated Using a Gore Excluder Limb Endoprosthesis

Agostinucci A, Data S, Pagliasso

Dacron vascular prostheses have been widely used in vascular surgery since the mid-1970s. They have been proven to be the most durable and reliable conduits for arterial replacement in aortic...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Collagen-coated Polyethylene Terephthalate Disc Plate and Shell Vial Culture Method for the Isolation of Chlamydophila pneumoniae

Kim MH, Lee WK

BACKGROUND: Chlamydophila pneumoniae is one of the major respiratory infectious pathogens and can be accurately diagnosed by cell culturing. The author performed this study to compare the usefulness of the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Trido Mitral Valve Replacement with Dacron Collar Prosthetic Valve due to Paravalvular Leak

Bae YS, Jung SC, Kim WS, Chung SH, Lee JH, Kim BY

  • KMID: 1916127
  • Korean J Thorac Cardiovasc Surg.
  • 2002 Nov;35(11):822-825.
The paravalvular leak after redo mitral prosthetic valve replacement is rare but serious complication when it does happen. This condition should be corrected surgically to increase life span and improve...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Non-Anastomotic Rupture of a Woven Dacron Graft in the Descending Thoracic Aorta Treated with Endovascular Stent Grafting

Lee Y, Kim GJ, Kim YE, Hong SW, Lee JT

The intrinsic structural failure of a Dacron graft resulting from the loss of structural integrity of the graft fabric can cause late graft complications. Late non-anastomotic rupture has traditionally been...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Aortic Root Replacement with Valve Preservation in a Patient with Annuloaortic Ectasia

Kim DJ, Yoon CS, Jang BC

  • KMID: 2288961
  • Korean J Thorac Cardiovasc Surg.
  • 1998 Dec;31(12):1234-1237.
Patients with aortic root disease, frequently seen in Marfan syndrome have progressive dilatation of the aortic sinuses and dilatation and distortion of the aortic annulus, leading to aortic incompetence. They...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Histopathologic Comparison of Vascularization between Dacron and Donor Sclera as Wrapping Material in Hydroxyapatite Implantation

Song ER, Choi KY, Yoon BJ

  • KMID: 2123158
  • J Korean Ophthalmol Soc.
  • 1993 Nov;34(11):1109-1116.
Recently, a hydroxyapatite sphere has been increasingly used as a buried integrated orbital implant for the great improved motility of the prosthesis after enucleation. To allow more rapid ascess of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Treatment of penile prosthetic infection with removal of the infected prosthesis and simultaneous implantation of a new one

Park WH, Choi WK, Kim SC, Park J, Shim HB

  • KMID: 2139550
  • Korean J Urol.
  • 1992 Jun;33(3):567-569.
Penile prosthesis implantation has become an established and a very successful method for treatment of the erectile dysfunction. But complications still occur, and the most devastating is infection. There has...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Radiological Characteristics of Materials Used in 3-Dimensional Printing with Various Infill Densities

Park SY, Choi N, Choi BG, Lee DM, Jang NY

Radiological properties of newly introduced and existing 3-dimensional (3D) printing materials were evaluated by measuring their Hounsfield units (HUs) at varying infill densities. The six materials for 3D printing which...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr