Skip Navigation
Skip to contents
Filter

ARTICLE TYPE

PUBLICATION DATE

8 results
Display

Determination of Quality Factors for Cylindrical Ionization Chambers in kV X-rays: Review of IAEA Dosimetry Protocol and Monte Carlo Calculations and Measurements for N23333 and N30001 Chambers

Lee KK, Jeong DH, Lim C, Chang SK, Moon SR

  • KMID: 1591040
  • Korean J Med Phys.
  • 2005 Jun;16(2):53-61.
The quality factors for cylindrical ionization chambers for kV X-rays were determined by Monte Carlo calculation and measurement. In this study, the X-rays of 60~300 kV beam (ISO-4037) installed in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Neutron Generation from a 24 MV Medical Linac

Lee JO, Jeong DH, Kang JK

  • KMID: 1591056
  • Korean J Med Phys.
  • 2005 Jun;16(2):97-103.
The energy spectra and dose calculations were performed for secondary neutrons from a 24 MV LINAC using MCNPX code (V2, 4, 0). The energy spectra for neutrons and photons emitted...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Characteristics of Detectors for Measurements of Photon Depth Doses in Build-Up Region

Kang SK, Cho BC, Park SW, Oh DH, Park HC, Kim SS, Bae H

  • KMID: 1591048
  • Korean J Med Phys.
  • 2005 Jun;16(2):77-81.
To determine the appropriate method out of various available methods to measure build-up doses, the measurements and comparisons of depth doses of build-up region including the surface dose were executed...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Interstitial Photodynamic Therapy (PDT) Set-up for Treating Solid Tumor Using Laser Diode

Kim KH, Kim JK

  • KMID: 1591057
  • Korean J Med Phys.
  • 2005 Jun;16(2):104-109.
Photodynamic therapy (PDT) is one of the expectable current cure operation methods. Tumor tissue is treated by abundant oxygen in a body and generated singlet or free radical from exterior...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Analysis of a Cerrobend Compensator and a Electronic Compensator Designed by a Radiation Treatment Planning System

Song JY, Nah BS, Chung WK, Ahn SJ, Nam TK, Yoon MS

  • KMID: 1591051
  • Korean J Med Phys.
  • 2005 Jun;16(2):82-88.
In this study, the physical compensator made with the high density material, Cerrobend, and the electronic compensator realized by the movement of a dynamic multileaf collimator were analyzed in order...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
An Effect of Time Gating Threshold (TGT) on the Delivered Dose at Internal Organ with Movement due to Respiration

Kim YL, Chung JB, Chung WK, Hong S, Suh TS

  • KMID: 1591053
  • Korean J Med Phys.
  • 2005 Jun;16(2):89-96.
In this study, we investigated the effect of time gating threshold on the delivered dose at a organ with internal motion by respiration. Generally, the internal organs have minimum motion...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Quality Assurance Program of Electron Beams Using Thermoluminescence Dosimetry

Rah JE, Suh TS, Kim GY, Jeong HK, Shin DO

  • KMID: 1591042
  • Korean J Med Phys.
  • 2005 Jun;16(2):62-69.
The purpose of this study has been performed to investigate the possibility of external audit program using thermoluminescence dosimetry for electron beam in korea. The TLD system consists of LiF...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Enhanced Dynamic Wedge with Physical Metal Wedge based on the Basic Dosimetric Parameters

Lee JW, Hong S, Choi KS, Chung JB, Choe BY, Jang HS, Suh TS

  • KMID: 1591044
  • Korean J Med Phys.
  • 2005 Jun;16(2):70-75.
For clinical implementation of Enhanced Dynamic Wedge (EDW), it is necessary to adequately analyze and commission its dosimetric properties in comparison to common physical metal wedge (MTW). This study was...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top