Dosimetric Impact of Ti Mesh on Proton Beam Therapy

Cho S, Goh Y, Kim C, Kim H, Jeong JH, Lim YK, Lee SB, Shin D

When a high density metallic implant is placed in the path of the proton beam, spatial heterogeneity can be caused due to artifacts in three dimensional (3D) computed tomography (CT)...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Feasibility of a Linear Diode Array Detector for Commissioning of a Radiotherapy Planning System

Hong SM, Lee U, Kim Sw, Goh Y, Park MJ, Jeong C, Kwak J, Cho B

Purpose: Although ionization chambers are widely used to measure beam commissioning data, point-by-point measurements of all the profiles with various field size and depths are timeconsuming tasks. As an alternative,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Dosimetric Accuracy of CyberKnife Stereotactic Radiosurgery for Perioptic Lesions

Yoon K, Jeong C, Park M, Goh Y, Kim S, Cho B, Kwak J, Cho YH

  • KMID: 2510080
  • Prog Med Phys.
  • 2020 Sep;31(S1):S37.
Purpose: This study aimed to evaluate the dosimetric accuracy of Cyberknife (CK) for benign perioptic tumor using patient specific QA head phantom. Methods: Patient specific head phantoms was fabricated using a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of the Skin Dose in TPS with the Phantom Measurement for the Head and Neck Radiation Treatment Patients

Hong SM, Kim Sw, Cho B, Goh Y, Kim C, Lee M, Shin JB, Lee D, Yoon K, Noh S, Kang S, Kwak J, Jeong C, Park MJ

  • KMID: 2510096
  • Prog Med Phys.
  • 2020 Sep;31(S1):S53.
Purpose: Head and neck cancer patients are radiation-treated on the couch tops with thermoplastic mask for the immobilization of patients. However, dose perturbation is occurred by the mask and leads...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Application of surface-guided radiation therapy in prostate cancer: comparative analysis of differences with skin marking-guided patient setup

Lee J, Kim YJ, Goh Y, Yang E, Kim HU, Song SY, Kim YS

Purpose: Surface-guided radiation therapy is an image-guided method using optical surface imaging that has recently been adopted for patient setup and motion monitoring during treatment. We aimed to determine whether...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Nutritional status and dietary behavior of North Korean adolescent refugees based on Nutrition Quotient for Korean adolescents: a preliminary study

Goh Y, Choi SW, Kim SY, Choi JH

Objectives: This study aimed to investigate the nutritional status and dietary behavior of adolescents from North...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of Filament Materials for Polymer Gel Dosimetry in Fused Deposition Modeling

Lee M, Noh S, Cho Bc, Kim Sw, Kim C, Shin JB, Hong SM, Goh Y, Park M, Yoon K, Jeong C, Kwak J

  • KMID: 2510079
  • Prog Med Phys.
  • 2020 Sep;31(S1):S35.
Purpose: Accurate dosimetric verification is becoming more crucial in radiotherapy, as modern treatment techniques require more complex beam control mechanisms and larger dose fraction sizes. Polymer gel dosimetry can be...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Methodology to Predict the Proton Beam Range from the Scintillated Light Distribution Using Deep-Learning

Lee E, Goh Y, Cho B, Kwak J, Jeong C, Yoon K, Park MJ, Kim Sw, Kim C, Lee M, Shin JB, Hong SM

  • KMID: 2510078
  • Prog Med Phys.
  • 2020 Sep;31(S1):S34.
Purpose: This study aims to predict the proton beam range with the conversion of the scintillated light distribution into the proton depth-dose distribution. The feasibility of the methodology using Deep-Learning...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Respiratory Motion Pattern Analysis of Lung Cancer Patient with Gated Treatment: A Preliminary Study

Kim Sw, Kim C, Park MJ, Kang S, Shin JB, Hong SM, Yoon K, Goh Y, Kim SS, Song S, Lee Sw, Jeong C, Cho B, Kwak J

  • KMID: 2510090
  • Prog Med Phys.
  • 2020 Sep;31(S1):S49.
Purpose: An external surrogate, represent respiratory tumor motion, based respiratory gating technique is a useful method for the treatment of a moving lung tumor. The success of this technique relies...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Feasibility of Data Redundancy for On-Line Geometric Calibration without Dedicated Phantom on the Varian OBI CBCT Systems: A Simulation Study

Kim C, Jeong C, Park MJ, Goh Y, Kim Sw, Lee M, Shin JB, Hong SM, Cho B, Song SY, Lee Sw, Cho S, Kwak J

  • KMID: 2510049
  • Prog Med Phys.
  • 2020 Sep;31(S1):S20.
Purpose: Most common method of geometric calibration is based on the analysis of the projection data of dedicated phantoms, composed of a certain number of fiducial markers. From the relationship...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of Phantom Dose in a Rotating Total Skin Electron Irradiation (RTSEI) Using Monte Carlo Method and Optically Stimulated Luminescent Dosimeter (OSLD)

Shin JB, Kim C, Lee D, Yoon K, Park MJ, Goh Y, Kim Sw, Lee M, Hong SM, Noh S, Kang S, Cho B, Kwak J, Jeong C

  • KMID: 2510038
  • Prog Med Phys.
  • 2020 Sep;31(S1):S10.
Purpose: The purpose is to study the optimal Rotating total skin electron irradiation (RTSEI) treatment method through phantom dose evaluation using Monte Carlo method and optically stimulated luminescent dosimeter (OSLD). Methods:...
CITED
export Copy