Performance and Cost of Disposable Biopsy Forceps in Upper Gastrointestinal Endoscopy: Comparison with Reusable Biopsy Forceps

Lim CH, Choi MG, Kim WC, Kim JS, Cho YK, Park JM, Lee IS, Kim SW, Choi KY, Chung IS

BACKGROUND/AIMS: It is believed that disposable biopsy forceps are more costly than reusable biopsy forceps. In this study, we evaluated performance and cost of disposable forceps versus reusable forceps in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Recent Progress in Lab-on-a-Chip Technology and Its Potential Application to Clinical Diagnoses

Lee NY

  • KMID: 2232849
  • Int Neurourol J.
  • 2013 Mar;17(1):2-10.
We present the construction of the lab-on-a-chip (LOC) system, a state-of-the-art technology that uses polymer materials (i.e., poly[dimethylsiloxane]) for the miniaturization of conventional laboratory apparatuses, and show the potential use...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Development of a Safe Syringe Disposal System Moving towards Automated Syringe Data Collection

Kim Y, Oh K, Kim N, Yun J

OBJECTIVES: An automatic needle destroyer (ANDY) was developed to prevent needlestick injuries, and usability tests were conducted in several hospitals. The addition of extra features to the ANDY is in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The impact of robotic surgery on gynecologic oncology

Nick AM, Ramirez PT

The objective of this article was to review the published scientific literature pertaining to robotic surgery and its applications in gynecologic malignancies and to summarize the impact of robotic surgery...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effects of Simple and Disposable Chicken Cages for Experimental Eimeria Infections

Yoo J, Kang SH, Jeong J, Kim WH, Kim S, Lillehoj H, Min W

During experimental Eimeria infections in chickens, facilities are often contaminated by fecal oocysts known to be highly resistant to both chemical and enzymatic treatments. Thus, studies using experimental Eimeria infections...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Tracheal Intubation Using the Macintosh Laryngoscope Versus the Disposable Laryngoscope by Inexperienced Personnel: A Manikin Study

Lee EH, Choi JH, Lim H, Cho YS, Lee JW, Lee B

PURPOSE: Disposable one piece laryngoscope (DOL), which probably carries a lower risk of infection than conventional reusable ones, is the only device which has received approval by the Korean Ministry...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Performance of disposable endoscopic forceps according to the manufacturing techniques

Kwon CI, Kim G, Moon JP, Yun H, Ko WJ, Cho JY, Hong SP

BACKGROUND/AIMS: Recently, to lower the production costs and risk of infection, new disposable biopsy forceps made using simple manufacturing techniques have been introduced. However, the effects of the manufacturing techniques...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Transparency to Reduce Surgical Implant Waste

Pfefferle , Dilisio MF, Patti B, Fening SD, Junko JT

BACKGROUND: Rising health care costs and emphasis on value have placed the onus of reducing healthcare costs on the surgeon. METHODS: Financial data from 3,973 hip, knee, and shoulder arthroplasties performed...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pathological Significance of Tissue Trapped in Retrieved OptEase Vena Cava Filter at 18th Day after Installation in Patient with Deep Vein Thrombosis

Park SM, Son JW, Hong KS, Choi KC

The retrievable type of inferior vena cava filter has been widely used to prevent pulmonary thromboembolism in patients with deep vein thrombosis and contraindication of anticoagulation. Physicians make considerable efforts...