Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

99 results
Display

The Availability of Contrast Sensitivity in Low Vision Patients

Park SL, Moon NJ

  • KMID: 2108524
  • J Korean Ophthalmol Soc.
  • 1998 Aug;39(8):1788-1793.
The standard vision test using visual acuity is not always an accurate indicator of functional visual loss. The contrast sensitivity was measured in low vision patients. the contrast sensitivity of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of Illumination on Contrast Sensitivity

Kim CS, Kim HK

  • KMID: 2122738
  • J Korean Ophthalmol Soc.
  • 1987 Aug;28(4):729-732.
The effect of illumination on the contrast sensitivity function was studied using an Arden Contrast Sensitivity System and incandescent electric lamp. The intensities of illumination were set at 50,100,200,500, and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Contrast Sensitivity in Non-Insulin Dependent Diabetics

Nah H, Kwon OW, Kim HB, Lim SJ

  • KMID: 2204744
  • J Korean Ophthalmol Soc.
  • 1986 Jun;27(3):317-320.
Contrast sensitivity measurements were obtained from 45 patients with noninsulin dependent diabetes mellitus(NIDDM) who had normal Snellen acuity and minimal or no visible diabetic retinopathy. Contrast sensitivity thresholds were determined...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Aasesament of Contrast Sensitivity by MCT 8000(R) in Normal Eyes and Peeudophakic Eyes

Kim YS, Yoo CS, Kim JH

  • KMID: 2107576
  • J Korean Ophthalmol Soc.
  • 1989 Oct;30(5):701-708.
The standard vision test using Snellen acuity is not always an accurate indicat or of functional vision loss. Acuity measures optical blur, but psudophakic eyes frequently do not affect optical...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Comparison of Contrast Sensitivity Between Strabismic and Anisometropic Amblyopia

Park SC, Lee WR

  • KMID: 1949592
  • J Korean Ophthalmol Soc.
  • 1991 Dec;32(12):1097-1103.
Contrast sensitivity was measured by MCT 8000(R)(Vistech Consultant INC, U.S.A.) in two groups: 23 strabismic amblyopes and 10 anisometropic amblyopes. In general, the amblyopic eyes exhibited a statistically significant loss...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Change of Contrast Sensitivity in Amblyopic Patient after Occlusion Therapy using ACV

Park SB, Han SH, Lee JB

  • KMID: 2125500
  • J Korean Ophthalmol Soc.
  • 2003 Oct;44(10):2299-2304.
PURPOSE: This study was designed to evaluate the change of contrast sensitivity under the photopic and mesopic illumination in amblyopic patient after occlusion therapy. METHODS: The subjects comprised 32 pediatric...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Contrast Sensitivity Changes in Patients with Diabetic Retinopathy

Kim EA, Koo YJ, Han YB

  • KMID: 2205116
  • J Korean Ophthalmol Soc.
  • 1995 Sep;36(9):1523-1528.
Changes in contrast sensitivity have been demonstrated in patients with normal Snellen acuity. In an attempt to elucidate more sensitively the visual dysfunction before developement of either overt retinopathy or...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Normal Contrast Sensitivity for Various Ages

You YC, Choi TH, Lee HB

  • KMID: 2206419
  • J Korean Ophthalmol Soc.
  • 2003 Jan;44(1):150-156.
PURPOSE: To estimate the mean contrast sensitivity of normal Korean people and determine the difference between various ages. METHODS: One hundred sixty eight eyes with normal vision and no ocular...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Optical Aberrations and Contrast Sensitivity between Monofocal and Multifocal Intraocular Lens

Lee JM, Seo KY, Kim EK

  • KMID: 2206198
  • J Korean Ophthalmol Soc.
  • 2002 Oct;43(10):1882-1886.
PURPOSE: The purpose of this study was to compare the postoperative contrast sensitivity and optical aberration between monofocal and multifocal IOL implanted patients. METHODS: Postoperative contrast sensitivity and optical aberration were...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Contrast Sensitivity Function of Sound Eye after Occlusion Therapy in the Amblyopic Children

Lew H, Han SH, Lee JB, Lee ES

To verify the changes of mesopic and photopic contrast sensitivity function of sound eye whose visual acuity was kept the same after occlusion therapy in the amblyopic children. Fourteen sound...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Reproducibility of Morphoscopic Contrast Sensitivity Obtained with the Visual Capacity Analyzer in Glaucoma Patients

Koh IH, Seong GJ

  • KMID: 2022132
  • J Korean Ophthalmol Soc.
  • 2003 Jun;44(6):1341-1345.
PURPOSE: To determine the reproducibility of morphoscopic contrast sensitivity test values in the patients with primary open angle glaucoma using the Visual Capacity Analyzer (ACV) designed for assessing full visual...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Comparative Study for Mesopic Contrast Sensitivity between Keratectomy(PRK) and Laser in Situ Keratomileusis(LASIK)

Jun JB, Lee JE, Lee JS

  • KMID: 2125915
  • J Korean Ophthalmol Soc.
  • 2004 Oct;45(10):1724-1730.
PURPOSE: To compare the effect on visual performance of photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) with mesopic contrast sensitivity using CSV-1000S in excimer laser refractive surgery using...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Evaluation of Contrast Sensitivity and Glare after LASIK Using Flying Spot Mode Laser According to Pupil Diameter and Refractive Error

Choi KD, Park HB, Lee DH

  • KMID: 2206283
  • J Korean Ophthalmol Soc.
  • 2002 Dec;43(12):2391-2400.
PURPOSE: To study the effect of LASIK using flying spot mode laser on contrast sensitivity and glare according to pupil diameter and preoperative refractive error. METHODS: Fifty seven eyes of 42...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Mesopic Contrast Sensitivity Functions in Amblyopic Children

Lew H, Seong GJ, Kim SK, Lee JB, Han SH

This study both measured and compared the mesopic contrast sensitivity function and the visual acuity in both normal and amblyopic eyes from amblyopic children using an ACV (visual acuity analyzer)....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Hue Discrimination and Contrast Sensitivity Deficits in Diabetic Subjects With and Without Retinopathy

Kim HG, Yoo CS, Huh W

  • KMID: 1949685
  • J Korean Ophthalmol Soc.
  • 1991 Mar;32(3):274-280.
In an attempt to assess the evidence of abnormal central vision before the development of either overt retinopathy or a reduction in visual acuity in patients with diabetes mellitus, hue...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Spherical Aberration, Contrast Sensitivity and Depth of Focus With Three Aspherical Intraocular Lenses

Bae HW, Kim EK, Kim TI

  • KMID: 2337756
  • J Korean Ophthalmol Soc.
  • 2009 Nov;50(11):1639-1644.
PURPOSE: To evaluate postoperative spherical aberration, contrast sensitivity and depth of focus after implanting 3 different aspheric intraocular lenses. METHODS: Fifty-six eyes (18 eyes for Akreos adapt Advanced Optics (AO), 20...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Relationship between Binocular Visual Function and Quality of Life in Bilateral Normal Tension Glaucoma Patients

Park HH, Chun YS

PURPOSE: To analyze the effect of stereopsis and contrast sensitivity on the quality of life and to evaluate the relationship between integrated binocular visual field (IVF) and binocular visual function...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Measurement of Contrast Sensitivity in Patients with Behçet's Disease without Ocular Involvement

Ozsoy E, Cankaya C, Ozturk E, Gunduz A, Ulucan PB

PURPOSE: To evaluate contrast sensitivity in patients with Behçet's disease (BD) without ocular involvement. METHODS: The study group was composed of 47 BD patients (20 to 50 years of age) who...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of Method of Illumination on the Visual Contrast Sensitivity Funetion

Yoo JI, Kim HK, Son WO, Choi KR

  • KMID: 2336484
  • J Korean Ophthalmol Soc.
  • 1988 Feb;29(1):139-142.
To find out the good visual environment for reading, the methods of illumination were studied using Arden Contrast Sensitivity System. Among various factors for comfortable reading condition such as air...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparisons of Visual Acuity, Spherical Aberration and Contrast Sensitivity among Spheric, Aspheric ReSTOR(R), and Crystalens HD(R) Lenses

Kang EC, Kim EK, Kim TI

  • KMID: 2338013
  • J Korean Ophthalmol Soc.
  • 2011 Nov;52(11):1275-1280.
PURPOSE: To assess visual acuity, spherical aberration and contrast sensitivity in patients who were implanted with spheric, aspheric ReSTOR(R) or Crystalens HD(R) lenses. METHODS: The present study enrolled 16 patients (32...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2025 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr