Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

20 results
Display

The Effect of Different Suturing Techniques on Astigmatism after Penetrating Keratoplasty

Kim SJ, Wee WR, Lee JH, Kim MK

The purpose of this study was to compare the effects on astigmatism after penetrating keratoplasty with three different suture techniques. In this prospective study, 38 eyes of 38 patients underwent...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical and pathological assessment of different suture techniques for microvascular anastomosis in rat femoral artery

Radad K, El-Shazly

This study examined the clinical and pathologicalfeatures after a microvascular anastomosis of a ratfemoral artery using four different suture techniques.Sixty Sprage-Dawely rats were divided randomly into 4groups. Fifteen bisected arteries...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Suture Bridge Fixation Technique for Posterior Cruciate Ligament Avulsion Fracture

Lee KW, Yang DS, Lee GS, Choy WS

We presented a surgical technique including a suture bridge technique with relatively small incision for the reduction and fixation of posterior ligament avulsion fractures. A suture anchor was used to...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Long-term results of implantation of posterior chamber intraocular lens by suture fixation

Chang JH, Lee JH

We reviewed the long-term results of implantation of posterior chamber intraocular lens (PC IOL) by suture fixation in 23 patients without zonular or capsular support. In terms of preoperative state,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Modified Mason-Allen Suture Bridge Technique: A New Suture Bridge Technique with Improved Tissue Holding by the Modified Mason-Allen Stitch

Lee BG, Cho NS, Rhee YG

We present a new method of suture bridge technique for medial row fixation using a modified Mason-Allen stitch instead of a horizontal mattress. Medial row configuration of the technique is...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Suture Fixation Technique for a Single-piece Foldable Closed-loop Intraocular Lens

Park CH, Lee SJ

PURPOSE: We describe a suture fixation technique for a single-piece foldable acrylic closed-loop intraocular lens (IOL) (C-flex(TM), Rayner). METHODS: In our experimental model analyzing the stability of acrylic...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Perioperative Modulating Factors on Astigmatism in Sutured Cataract Surgery

Cho YK, Kim MS

PURPOSE: To evaluate the factors that affect postoperative astigmatism and post-suture removal astigmatism, and to evaluate the risk factors associated with astigmatism axis shift. METHODS: We performed a retrospective chart...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Full Tendon Transposition Augmented with Posterior Intermuscular Suture and Recession-Resection Surgery

Hong S, Chang YH, Han SH

PURPOSE: To report an effect of the full tendon transposition augmented with posterior intermuscular suture and recession-resection surgery, for the patient with monocular elevation deficiency (MED) and large exotropia. ...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Safe Excision of a Large Overhanging Cystic Bleb Following Autologous Blood Injection and Compression Suture

Ng DS, Ching RH, Yam JC, Chan CW

Here, we report a large, overhanging cystic bleb that compromised vision and induced a foreign body sensation in a patient who underwent a trabeculectomy surgery with anti-metabolite therapy 4 years...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Implantation of posterior chamber intraocular lenses by suture fixation without capsular and zonular support

Chang JH, Lee JH

We implanted sulcus-fixated posterior chamber intraocular lenses (PCL) in three cataractous, six aphakic, and four eyes during penetrating keratoplasty due to corneal opacity in the absence of capsular and zonular...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Arthroscopic Suture Bridge Repair Technique for Full Thickness Rotator Cuff Tear

Yi JW, Cho NS, Cho SH, Rhee YG

BACKGROUND: The purpose of our study is to evaluate the clinical results of arthroscopic suture bridge repair for patients with rotator cuff tears. METHODS: Between January 2007 and July 2007, fifty-one...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Colored Ring-Shaped Thread Tag Clippings to Identify the Accurate Location of Multiple Polyps Resected via Endoscopic Mucosal Resection

Mori H, Kobara H, Masaki T

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical and Radiological Evaluation after Arthroscopic Rotator Cuff Repair Using Suture Bridge Technique

Lee KW, Seo DW, Bae KW, Choy WS

BACKGROUND: We retrospectively assessed the clinical outcomes and investigated risk factors influencing retear after arthroscopic suture bridge repair technique for rotator cuff tear through clinical assessment and magnetic resonance arthrography...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Intraoperative Adjustment in Strabismus Surgery under Topical Anesthesia

Chang YH, Ryu IH, Han SH, Lee SJ, Lee JB

We evaluated the one-stage intraoperative adjustment strabismus surgery with adjustable suture under topical anesthesia. Medical records of the patients who had intraoperative adjustment surgery under topical anesthesia for horizontal or...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The clinical application of the sliding loop technique for renorrhaphy during robot-assisted laparoscopic partial nephrectomy: Surgical technique and outcomes

Kim HS, Lee YJ, Ku JH, Kwak C, Kim HH, Jeong CW

PURPOSE: To report the initial clinical outcomes of the newly devised sliding loop technique (SLT) used for renorrhaphy in patients who underwent robot-assisted laparoscopic partial nephrectomy (RALPN) for small renal...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of the Stability of Postoperative Alignment in Sensory Exotropia: Adjustable Versus Non-Adjustable Surgery

Park YC, Chun BY, Kwon JY

PURPOSE: To compare the success rates and stabilities of postoperative alignment between adjustable and the non-adjustable surgeries in the treatment of sensory exotropia. METHODS: A retrospective analysis was performed on...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Safety and Efficacy of Transconjunctival Sutureless 23-gauge Vitrectomy

Kim MJ, Park KH, Hwang JM, Yu HG, Yu YS, Chung H

PURPOSE: To evaluate the efficacy and safety of vitreoretinal surgery using a 23-gauge transconjunctival sutureless vitrectomy (TSV) system for various vitreoretinal diseases. METHODS: A retrospective, consecutive, interventional case...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of Electrocauterization on the Inflammation of the Conjunctiva in Experimental Animal Model

Kim KH, Ko AY, Ryu JS, Kim MK, Wee WR

PURPOSE: Recently, conjunctivochalasis repair surgery using electrocauterization has been gaining popularity. However, patients with electrocauterized conjunctivoplasty tend to complain of more postoperative pain than patients undergoing simple excision with suturing....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Unilateral Scleral Fixation of Posterior Chamber Intraocular Lenses in Pediatric Complicated Traumatic Cataracts

Hyun DW, Lee TG, Cho SW

PURPOSE: The purpose of this study was to evaluate the visual outcomes and complications of unilateral scleral fixation of posterior chamber intraocular lenses (SF-PCIOLs) in pediatric complicated traumatic cataracts without...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Ptosis Repair Using Preserved Fascia Lata with the Modified Direct Tarsal Fixation Technique

Suh JY, Ahn HB

PURPOSE: To evaluate the clinical outcome of frontalis sling operation using preserved fascia lata with modified direct tarsal fixation in congenital ptosis patients. METHODS: Forty-seven congenital ptosis patients (60 eyes) who...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr