Liquid Chromatography-Mass Spectrometry-Based In Vitro Metabolic Profiling Reveals Altered Enzyme Expressions in Eicosanoid Metabolism

Lee SH, Kim EJ, Lee DH, Lee WY, Chung BC, Seo HS, Choi MH

BACKGROUND: Eicosanoids are metabolites of arachidonic acid that are rapidly biosynthesized and degraded during inflammation, and their metabolic changes reveal altered enzyme expression following drug treatment. We developed an eicosanoid...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Quantification of Human Plasma-Busulfan Concentration by Liquid Chromatography-Tandem Mass Spectrometry

Moon SY, Lim MK, Hong S, Jeon Y, Han M, Song SH, Lim KS, Yu KS, Jang IJ, Lee JW, Kang HJ, Song J

BACKGROUND: Busulfan, an alkylating agent administered prior to hematopoietic stem cell transplantation, has a narrow therapeutic range and wide variability in metabolism. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS)...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Dried Blood Spot Testing for Seven Steroids Using Liquid Chromatography-Tandem Mass Spectrometry With Reference Interval Determination in the Korean Population

Kim B, Lee MN, Park HD, Kim JW, Chang YS, Park WS, Lee SY

BACKGROUND: Conventional screening for congenital adrenal hyperplasia (CAH) using immunoassays generates a large number of false-positive results. A more specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been introduced to...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Validity of Glycated Hemoglobin in Screening and Diagnosing Type 2 Diabetes Mellitus in Chinese Subjects

Yu Y, Ouyang XJ, Lou QL, Gu LB, Mo YZ, Ko GT, Chow CC, So WY, Ma R, Kong A, Brown N, Nan J, Chan J, Bian RW

BACKGROUND/AIMS: The application of glycated hemoglobin (HbA1c) for the diagnosis of diabetes is currently under extensive discussion. In this study, we explored the validity of using HbA1c as a screening...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Assessment of the Trueness and Inter-Laboratory Precision of Routine Uric Acid Assays Using 4 Frozen Pooled Serum Samples Measured by the Japan Society of Clinical Chemistry's HPLC Method

Jiang Y, Liu O, Xu G

BACKGROUND: Reference procedures are required for evaluating the accuracy of routine analytical systems for uric acid (UA). External quality assessment (EQA) for UA has only been conducted with quality controls...