Korean J Ophthalmol.  2025 Apr;39(2):103-113. 10.3341/kjo.2024.0106.

Anterior Segment Swept-Source Optical Coherence Tomography–based Assessment of Corneal Refractive Profiles in Stevens-Johnson Syndrome/Toxic Epidermal Necrolysis Patients: A Controlled Comparative Study

Affiliations
  • 1Department of Ophthalmology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Korea
  • 2Department of Ophthalmology, Chung-Ang University Gwangmyeong Hospital, Chung-Ang University College of Medicine, Gwangmyeong, Korea

Abstract

Purpose
To analyze anterior, posterior, and total corneal refractive profiles and thickness using anterior segment (AS) sweptsource optical coherence tomography (SS-OCT) in Stevens-Johnson syndrome (SJS) or toxic epidermal necrolysis (TEN) patients.
Methods
This retrospective study compared 23 eyes from 14 patients with SJS/TEN with 23 eyes from 14 age- and sexmatched controls. AS SS-OCT measured corneal refractive profiles and pachymetry. Parameters included anterior, posterior, and total corneal power values, posterior to anterior curvature ratio, maximal corneal power, and thickness profiles. The SJS/TEN group was subdivided based on corneal opacity presence (subgroup A) or absence (subgroup B).
Results
The SJS/TEN group showed significantly higher corneal astigmatism and maximal corneal power values for both anterior and posterior curvatures. Steep total corneal power and total corneal astigmatism were higher in the SJS/TEN group. The thinnest corneal thickness was lower, and its distance from the corneal vertex was greater in the SJS/TEN group. Subgroup analysis revealed that these differences were primarily attributed to the presence of corneal opacity. Additionally, automated keratometry of the anterior corneal surface showed significantly higher values, including steep, flat, and average keratometry and corneal astigmatism, in the SJS/TEN group.
Conclusions
AS SS-OCT shows significant alterations in both anterior and posterior corneal curvatures in patients with SJS/TEN. These findings emphasize the importance of considering posterior corneal curvature changes in pre-cataract surgery assessments and contact lens prescriptions for patients with SJS/TEN.

Keyword

Anterior segment swept-source optical coherence tomography; Posterior corneal curvature; Stevens-Johnson syndrome; Toxic epidermal necrolysis
Full Text Links
  • KJO
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2025 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr