J Adv Prosthodont.  2024 Aug;16(4):201-211. 10.4047/jap.2024.16.4.201.

Palatal vault configuration and its influence on intraoral scan time and accuracy in completely edentulous arches: a prospective clinical study

Affiliations
  • 1Department of Prosthodontics, Faculty of Dentistry, MSA University, Giza, Egypt
  • 2Department of Prosthodontics, Faculty of Oral and Dental Medicine, Delta University for Science and Technology, Dakahlia, Egypt
  • 3Department of Prosthodontics, Faculty of Dentistry, Ahram Canadian University, Giza, Egypt
  • 4Department of Prosthodontics, Faculty of Dentistry, Cairo University, Giza, Egypt

Abstract

PURPOSE
The aim of this prospective clinical study was to compare the influence of palatal vault forms on accuracy and speed of intraoral (IO) scans in completely edentulous cases.
MATERIALS AND METHODS
Based on the palatal vault form, participants were divided into three equal groups (n = 10 each); Class I: moderate; Class II: deep; Class III: flat palatal vault. A reference model was created for each patient using polyvinylsiloxane impression material. The poured models were digitized using an extraoral scanner. The resultant data were imported as a solid CAD file into 3D analysis software (GOM Inspect 2018; Gom GmbH, Braunschweig, Germany) and aligned using the software’s coordinate system to determine its X, Y, and Z axes. Five digital impressions (DIs) of maxilla were captured for each patient using an intraoral scanner (TRIOS; 3Shape A/S, Copenhagen, Denmark) and the resultant Standard Tessellation Language (STL) scan files served as test models. Trueness was evaluated by calculating arithmetic mean deviation (AMD) of the vault area between reference and test files while precision was evaluated by calculating AMD between captured scans to measure repeatability of scan acquisition. The scan time taken for each participant was also recorded.
RESULTS
There was no significant difference in trueness and precision among the groups (P = .806 and .950, respectively). Average scan time for Class I and III palatal vaults was 1 min 13 seconds and 1 min 37 seconds, respectively, while class II deep palatal vaults showed the highest scan time of 5 mins.
CONCLUSION
Palatal vault form in edentulous cases has an influence on scan time. However, it does not have a substantial impact on the accuracy of the acquired scans.

Keyword

Flat palatal vault; Deep palatal vault; Moderate palatal vault; Scan accuracy; Scan time
Full Text Links
  • JAP
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr