J Cardiovasc Imaging.  2024;32(1):22. 10.1186/s44348-024-00015-4.

Assessment of right ventricular systolic function using speckle tracking strain imaging in patients with severe tricuspid regurgitation: a validation study with cardiac magnetic resonance

Affiliations
  • 1Department of Internal Medicine, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon, Republic of Korea
  • 2Division of Cardiology, Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea
  • 3Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea
  • 4Department of Internal Medicine, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, Republic of Korea

Abstract

Background
Right ventricular (RV) systolic dysfunction is an established prognostic factor in patients with severe tri‑ cuspid regurgitation (TR). However, accurate assessment of RV systolic function using conventional echocardiography remains challenging. We investigated the accuracy of strain measurement using speckle tracking echocardiography (STE) for evaluating RV systolic function in patients with severe TR.
Methods
We included consecutive patients with severe TR who underwent echocardiography and cardiac magnetic resonance imaging (CMR) within 30 days between 2011 and 2023. Two-dimensional STE was used to measure RV free wall longitudinal strain (RVFWLS) and global longitudinal strain (RVGLS). These values were compared with the RV ejection fraction (RVEF) from CMR. RV systolic dysfunction was defined as a CMR-derived RVEF < 35%.
Results
A total of 87 patients with severe TR were identified during the study period. Among echocardiographic RV strain measurements, RVFWLS was the best correlate of CMR-derived RVEF (r = –0.37, P < 0.001), followed by RVGLS (r = –0.27, P = 0.012). Receiver operating characteristic (ROC) curve analysis revealed that RVFWLS provided better dis‑ crimination of RV systolic dysfunction, yielding an area under the ROC curve (AUC) of 0.770 (95% confidence interval [CI], 0.696–0.800) than RV fractional area change (AUC, 0.615; 95% CI, 0.500–0.859).
Conclusions
In patients with severe TR, STE-derived RVFWLS showed the best correlation with RVEF on CMR and dis‑ played superior discrimination of RV systolic dysfunction compared with the RV fractional area change. This study suggests the potential usefulness of STE in assessing RV systolic function in this population.

Keyword

Echocardiography; Right ventricular dysfunction; Tricuspid valve insufficiency; Global longitudinal strain
Full Text Links
  • JCVI
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr