J Adv Prosthodont.  2024 Jun;16(3):139-150. 10.4047/jap.2024.16.3.139.

Accuracy and time efficiency of conventional and digital outlining of extensions of denture foundation on preliminary casts

Affiliations
  • 1Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, Rio Grande do Norte, Brazil
  • 2Potiguar University (UnP), Natal, Rio Grande do Norte, Brazil
  • 3Department of Oral Rehabilitation, Faculty of Dentistry, University of Pernambuco (UPE), Recife, Pernambuco, Brazil
  • 4Department of Gerodontology and Reconstructive Dentistry, University of Bern, School of Dentistry, Bern, Switzerland
  • 5Department of Restorative, Preventive, and Pediatric Dentistry, University of Bern, School of Dentistry, Bern, Switzerland
  • 6Division of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, OH, USA

Abstract

PURPOSE
The purpose of this diagnostic study was to assess the accuracy and time efficiency of a digital method to draw the denture foundation extension outline on preliminary casts compared with the conventional technique.
MATERIALS AND METHODS
A total of 28 preliminary edentulous casts with no anatomical landmarks were digitized using a laboratory scanner. The outlining of the entire basal seat of the denture was performed on preliminary casts and digitized. Casts with no extension outline were digitized and outlines were drawn using software (DWOS, Straumann). The accuracy of the extension outlined between both techniques was evaluated in the software (GOM Inspect; GOM GmbH) by file superimposition. Specificity and sensitivity tests were applied to measure accuracy. The paired t-test (95% CI) was used to compare the mean total area and the working time.
RESULTS
The accuracy ranged from 0.57 to 0.92. The buccal and labial frenulum showed a lower value in the maxilla (0.57); while the area between the retromolar pad and buccal frenulum (0.64) showed a lower score in the mandible. The maxillary denture foundation and the working time for both arches were significantly longer for the digital method (P < .001).
CONCLUSION
The denture foundation extension outline exhibited a sufficiently excellent accuracy for the digital method, except for the maxillary anterior region. However, the digital method required a longer working time.

Keyword

Accuracy; Computer-aided design; Complete denture; Denture foundation; Edentulous mouth
Full Text Links
  • JAP
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr