J Chest Surg.  2024 May;57(3):231-239. 10.5090/jcs.23.128.

Change in Pulmonary Arteries after Modified Blalock-Taussig Shunt Procedure: Analysis Based on Computed Tomography

Affiliations
  • 1Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul, Korea
  • 2Division of Congenital and Pediatric Cardiovascular Surgery, Seoul National University Children’s Hospital, Seoul National University College of Medicine, Seoul, Korea

Abstract

Background
Although the modified Blalock-Taussig shunt remains the mainstay method of palliation for augmenting pulmonary blood flow in various congenital heart diseases, the shunt must be carefully designed to achieve the best outcomes. This study investigated the effect of shunt configuration on pulmonary artery growth and growth discrepancy.
Methods
Twenty patients with successful modified Blalock-Taussig shunt takedown were analyzed. Pulmonary artery and shunt characteristics were obtained using computed tomography scans. Differences in the baseline and follow-up diameter ratios and growth in the ipsilateral and contralateral arteries were calculated. The angle between the shunt and pulmonary artery, as well as the distance from the main pulmonary artery bifurcation, were measured. Correlations between pulmonary arteries and shunt configurations were analyzed.
Results
The median interval time between shunt placement and takedown was 154.5 days (interquartile range, 113.25–276.25 days). Follow-up values of the ipsilateral-to-contralateral pulmonary artery diameter ratio showed no significant correlation with the shunt angle (ρ=0.429, p=0.126) or distance (ρ=0.110, p=0.645). The shunt angle and distance from the main pulmonary bifurcation showed no significant correlation (ρ=-0.373, p=0.189). Pulmonary artery growth was negatively correlated with shunt angle (ipsilateral, ρ=-0.565 and p=0.035; contralateral, ρ=-0.578 and p=0.030), but not with distance (ipsilateral, ρ=-0.065 and p=0.786; contralateral, ρ=-0.130 and p=0.586).
Conclusion
Shunt configuration had no significant effect on growth imbalance. The angle and distance of the shunt showed no significant correlation with each other. A more vertical shunt was associated with significant pulmonary artery growth. We suggest a more vertical graft design for improved pulmonary artery growth.

Keyword

Modified Blalock-Taussig shunt; Shunt angle; Shunt configuration; Pulmonary artery growth; Computed tomography