Maxillofac Plast Reconstr Surg.  2023;45(1):19. 10.1186/s40902-023-00387-5.

Digital implant placement accuracy: a clinical study on a fully‑guided flapless single‑unit immediate‑loading protocol

Affiliations
  • 1School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
  • 2Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
  • 3Department of Oral and Maxillofacial Surgery, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran

Abstract

Aims The primary aim of the present study was to measure the discrepancy between the virtual and the actual position of the single-unit implants placed via a digitally-designed fully-guided surgical template using a flapless surgical technique. Prefabricated provisional restorations and periodontal factors were evaluated after the immediate loading of implants and 3 months after the surgery, respectively.
Materials and methods
Fourteen implants in nine patients were virtually planned after importing intraoral scans and cone-beam computed tomography (CBCT) records into 3D planning software. Accordingly, fully-guided surgical templates, customized abutments, and provisional restorations were designed and fabricated. The implant position after the surgery was compared with its virtual counterpart in terms of angular and apical linear deviations. Implants were immediately loaded after the surgery, and the occlusal level of the delivered provisional restorations was compared with their designed positions. Early implant failure, bleeding on probing, and peri-implant pockets were documented on the 3-month follow-up.
Results
A mean angular deviation of 5.07 ± 2.06° and a mean apical linear deviation of 1.74 ± 0.63 mm resulted. Two out of 14 implants failed within the first 3 months of the surgery, and the occlusal level difference was calculated for nine prefabricated provisional restorations.
Conclusions
DIONAVI protocol has been evaluated regarding its accuracy, and an estimation of the expected deviation is presented to the clinicians using this protocol. However, before widespread use, immediate-loading protocols and provisional restorations must be studied further.

Keyword

Single-tooth dental implants; Immediate dental implant loading; Computer-assisted surgery; Computeraided design
Full Text Links
  • MPRS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr