J Korean Acad Prosthodont.  2024 Jan;62(1):20-27. 10.4047/jkap.2024.62.1.20.

Case series of implant-supported fixed prostheses using a high-performance polymer (PEKK) framework veneered with three different materials for six years

Affiliations
  • 1Department of Dentistry, Korea University Guro Hospital, Seoul, Korea

Abstract

As a high-performance polymer, Polyetherketoneketone (PEKK) has good biocompatibility and excellent physical properties and is used in several areas, including dentistry. Many successful cases of implant-supported fixed prostheses with a PEKK framework have been reported; however, a long-term observation of the reported cases and discussion of complications are not available. In this case report, we present three cases of implant-supported fixed prostheses with a PEKK framework veneered with composite resin, lithium disilicate crown, and high-impact polymethyl methacrylate (PMMA), and discuss their 6-year follow-up results.

Keyword

Dental implant; Polyetherketoneketone; Computer-aided design-computer-aided manufacturing