J Neurogastroenterol Motil.  2024 Jan;30(1):46-53. 10.5056/jnm23057.

Interpretation of Impedance Data on High-resolution Impedance Manometry Studies—A Worldwide Survey

Affiliations
  • 1Division of Gastroenterology, Hepatology, and Nutrition, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
  • 2Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA
  • 3Division of Biostatistics and Epidemiology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA

Abstract

Background/Aims
Esophageal manometry is the gold standard for esophageal motility evaluation. High-resolution esophageal manometry with impedance (HRIM) allows concurrent assessment of bolus transit and manometry. Inconsistencies between concomitant impedance and manometry data pose a clinical dilemma and has not yet been addressed. We aim to assess interpretation trends of HRIM data among gastroenterologists worldwide.
Methods
A cross-sectional study using an anonymous survey was conducted among gastroenterologists worldwide. Statistical analysis was performed to compare responses between providers.
Results
We received responses from 107 gastroenterologists (26 countries). Most were adult providers (69, 64.5%), and most (77, 72.0%) had > 5 years of experience. Impedance was found to be helpful by 83 (77.6%) participants, but over 30% reported inconsistencies between impedance and manometry data. With incomplete bolus clearance and normal manometry 41 (38.7%) recommended observation, 41 (38.7%) recommended 24-hours pH-impedance, and 16 (15.1%) recommended prokinetics. With abnormal manometry and complete bolus clearance, 60 (57.1%) recommended observation while 18 (17.1%) recommended 24-hours pH impedance and 15 (14.3%) recommended prokinetics. A significant difference was found between providers from different continents in treating cases with discrepancy between impedance and manometry findings (P < 0.001). No significant differences were seen in responses between adult versus pediatric providers and between providers with different years of experience.
Conclusions
There is no consensus on interpreting HRIM data. Providers’ approaches to studies with inconsistencies between manometry and impedance data vary. There is an unmet need for guidelines on interpreting impedance data in HRIM studies.

Keyword

Esophageal manometry; High-resolution impedance manometry; Impedance; Manometry