Clin Orthop Surg.  2023 Jun;15(3):436-443. 10.4055/cios22360.

Safe Optimal Tear Drop View for Spinopelvic Fixation Using a Three-Dimensional Reconstruction Model of the Pelvis

Affiliations
  • 1Department of Orthopedic Surgery, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Korea
  • 2Department of Orthopedic Surgery, Korea University Guro Hospital, Korea University College of Medicine, Seoul, Korea
  • 3Department of Orthopedic Surgery, Inje University Sanggye Paik Hospital, College of Medicine, Inje University, Seoul, Korea
  • 4Medical Device Development Center, Osong Medical Innovation Foundation, Cheongju, Korea

Abstract

Background
Spinopelvic fixation (SPF) has been a challenge for surgeons despite the advancements in instruments and surgical techniques. C-arm fluoroscopy-guided SPF is a widely used safe technique that utilizes the tear drop view. The tear drop view is an image of the corridor from the posterior superior iliac spine to the anterior inferior iliac spine (AIIS) of the pelvis. This study aimed to define the safe optimal tear drop view using three-dimensional reconstruction of computed tomography images.
Methods
Three-dimensional reconstructions of the pelvises of 20 individuals were carried out. By rotating the reconstructed model, we simulated SPF with a cylinder representing imaginary screw. The safe optimal tear drop view was defined as the one embracing a corridor with the largest diameter with the inferior tear drop line not below the acetabular line and the lateral tear drop line medial to the AIIS. The distance between the lateral border of the tear drop and AIIS was defined as tear drop index (TDI) to estimate the degree of rotation on the plane image. Tear drop ratio (TDR), the ratio of the distance between the tear drop center and the AIIS to TDI, was also devised for more intuitive application of our simulation in a real operation.
Results
All the maximum diameters and lengths were greater than 9 mm and 80 mm, respectively, which are the values of generally used screws for SPF at a TDI of 5 mm and 10 mm in both sexes. The TDRs were 3.40 ± 0.41 and 3.35 ± 0.26 in men and women, respectively, at a TDI of 5 mm. The TDRs were 2.26 ± 0.17 and 2.14 ± 0.12 in men and women, respectively, at a TDI of 10 mm.
Conclusions
The safe optimal tear drop view can be obtained with a TDR of 2.5 to 3 by rounding off the measured values for intuitive application in the actual surgical field.

Keyword

Pelvis; Spinal fusion; Tear drop view; Spinopelvic fixation; Three-dimensional
Full Text Links
  • CIOS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr