J Korean Acad Oral Health.  2022 Jun;46(2):92-98. 10.11149/jkaoh.2022.46.2.92.

Reduction in malodor, gingival index and plaque index after 4-week use of new concept oral irrigator

Affiliations
  • 1Department of Pediatric Dentistry, College of Dentistry, Dankook University, Cheonan, Korea

Abstract


Objectives
This study aimed to evaluate the changes in clinical indexes related to periodontitis, such as malodor, gingival and plaque indexes, during the adjuvant use of a high pressure oral irrigator (COMORAL ® , SMDsolutions, Seoul, Korea) in volunteers.
Methods
We recruited 17 volunteers from an advertisement posted on Dankook University’s bulletin board. The oral malodor, gingival index, and plaque index of each volunteer were during the adjuvant use of a high pressure oral irrigator within a 4-week period.
Results
Routine tooth brushing was done together with the adjuvant use of a new high pressure oral irrigator in the 4-week period. The oral malodor, gingival index, and plaque index measured after 2 and 4 weeks of use significantly decreased (P<0.05) compared with the baseline values obtained before the start of the study.
Conclusions
The adjuvant use of a new high pressure oral irrigator with routine tooth brushing in volunteers may more effectively manage daily oral hygiene.

Keyword

Gingival index; High pressure oral irrigator; Malodor; Oral hygiene; Plaque index

Figure

  • Fig. 1 Holes of WATERET® - COMORAL® mouthpiece (SMDsolutions, Seoul, Korea).

  • Fig. 2 BB Checker (mBA21, Plustech, Daejeon, Korea).

  • Fig. 3 Changes of gingival index for 4 weeks (n=17; *P<0.001 vs. baseline).

  • Fig. 4 Changes of plaque index for 4 weeks (n=17; *P<0.001 vs. baseline).

  • Fig. 5 WATERET® - COMORAL® mouthpiece (SMDsolutions, Seoul, Korea).


Reference

References

1. Loe H, Theilade E, Jensen JB. 1965; Experimental gingivitis in man. J Periodontol. 36:177–187. DOI: 10.1902/jop.1965.36.3.177. PMID: 14296927. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84873789097&origin=inward.
Article
2. Loe H, Silness J. 1963; Periodontal disease in pregnancy. I. Prevalence and severity. Act Odont Scand. 21:533–551. DOI: 10.3109/00016356309011240. PMID: 14121956. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=75549115165&origin=inward.
Article
3. Page RC, Schroeder HE. 1976; Pathogenesis of inflammatory periodontal disease. A summary of current work. Lab Invest. 33:235–249. PMID: 765622. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0017275766&origin=inward.
4. Yankell SL. 1991. Toothbrushing and tooth brushing techniques. Primary preventive dentistry. 3rd ed. Appleton and Lange;Norwalk: p. 79–106. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0017275766&origin=inward.
5. Kleber CJ, Putt MS, Muhler JC. 1981; Duration and pattern of toothbrushing in children using gel or paste dentifrice. J Am Dent Assoc. 103:723–726. DOI: 10.14219/jada.archive.1981.0377. PMID: 6946138. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0019642765&origin=inward.
Article
6. Cumming BR, Loe H. 1973; Consistency of plaque distribution in individuals without special home care instruction. J Periodont Res. 8:94–100. DOI: 10.1111/j.1600-0765.1973.tb00748.x. PMID: 4267951. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0015541089&origin=inward.
Article
7. Bruun C, Ekstrand KR, Andreasen KB. 1998; A new in vitro method for testing the interproximal cleaning potential of toothbrushing. J Clin Dent. 9:11–15. PMID: 9835827. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0031987205&origin=inward.
8. Axelsson P. Needs-related plaque control measures based on risk prediction. In : Proceedings of the European workshop on mechanical plaque control; 1998; Quintessence Chicago. p. 190–247. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0031987205&origin=inward.
9. Cumming BR, Loe H. 1973; Optimal dosage and method of delivering chlorhexidine solution for the inhibition of dental plaque. J Periodont Res. 8 Suppl 2:S57–62. DOI: 10.1111/j.1600-0765.1973.tb00751.x. PMID: 4267946.
10. Lang LG, Raber K. 1981; Use of oral irrigator as vehicle for the application of anti-microbial agents in chemical plaque control. J Clin Periodontol. 8 Suppl 3:S177–188. DOI: 10.1111/j.1600-051X.1981.tb02029.x. PMID: 6947984. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0019450019&origin=inward.
11. Parsons LG, Thomas LG, Southard GL. 1987; Effect of sanguinaria extract on established plaque and gingivitis when supragingivally delivered as a manual rinse or under pressure in an oral irrigator. J Clin Periodontol. 14 Suppl 7:S381–385. DOI: 10.1111/j.1600-051X.1987.tb01540.x. PMID: 3476514. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0342283700&origin=inward.
Article
12. Hugoson A. 1978; Effect of the Water Pik device on plaque accumulation and development of gingivitis. J Clin Periodontol. 5:95–104. DOI: 10.1111/j.1600-051X.1978.tb01911.x. PMID: 350911. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0018194554&origin=inward.
Article
13. Paju S, Pussinen PJ, Suominen-Taipale L, Hyvonen M, Knuuttila M, Kononen E. 2009; Detection of multiple pathogenic species in saliva is associated with periodontal infection in adults. J Clin Microbiol. 47:235–238. DOI: 10.1128/JCM.01824-08. PMID: 19020069. PMCID: PMC2620834. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=58849145780&origin=inward.
Article
14. Ravindrareddy N, Madhubabu D S, Mahendraraju C, Himasilpa C, Kiran K. 2012; Clinical effects of professional antimicrobial subgingival pulsated jet irrigation [WaterPik®] in patients with chronic periodontitis: A comparative study. J NTR Univ Health Sci. 1:38–45. DOI: 10.4103/2277-8632.94174.
Article
15. Lobene RR. 1969; The effect of a pulsed water pressure cleansing device on oral health. J Periodontol. 40 Suppl 11:S667–670. DOI: 10.1902/jop.1969.40.11.667. PMID: 5260628. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0014595910&origin=inward.
Article
16. York TA, Dunkin RT. 1967; Control of periodontal problems in orthodontics by use of water irrigation. Am J Orthod. 9:639–650. DOI: 10.1016/0002-9416(67)90175-3. PMID: 4166779. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0014124803&origin=inward.
Article
17. Phelps-Sandall BA, Oxford SJ. 1983; Effectiveness of oral hygiene techniques on plaque and gingivitisin patients placed in intermaxillary fixation. Oral Surg Oral Med Oral Pathol. 56:487–490. DOI: 10.1016/0030-4220(83)90094-4. PMID: 6580593. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0020853319&origin=inward.
Article
18. Tannenbaum K.A., Miller J.W.. 1960; Oral conditions of the mentally retarded patient. J Dent Child. 25:277–280. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0020853319&origin=inward.
19. Chaves ES, Kornman KS, Manwell MA, Jones AA, Newbold DA, Wood RC. 1994; Mechanism of irrigation effects on gingivitis. J Periodontol. 65:1016–1021. DOI: 10.1902/jop.1994.65.11.1016. PMID: 7853124. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0028538026&origin=inward.
Article
20. Goyal R, Lyle DM, Qaqish JG, Schuller R. 2013; Evaluation of the plaque removal efficacy of a water flosser compared to string floss in adults after a single use. J Clin Dent. 24:37–42. PMID: 24282867. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84888247831&origin=inward.
21. Park GD. 2014; Comparison of High Pressure Spray Oral Hygienic Appliance and Sonic Vibration Toothbrush in Reduction of Dental Plaque. J Korean Acad Oral Health. 38:71–76. DOI: 10.11149/jkaoh.2014.38.2.71.
Article
22. Hoover D R, Robinson H B. 1971; The comparative effectiveness of a pulsating oral irrigator as an adjunct in maintaining oral health. J Periodontol. 42 Supp 1:S37–39. DOI: 10.1902/jop.1971.42.1.37. PMID: 5276430. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0014975725&origin=inward.
Article
23. Selting WJ, Bhaskar SN, Mueller RP. 1972; Water jet direction and periodontal pocket debridement. J Periodontol. 43 Supp 9:S569–572. DOI: 10.1902/jop.1972.43.9.569. PMID: 4506704. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0015395531&origin=inward.
Article
24. Tonzetich J. 1977; Production and origin of oral malodor: a review of mechanisms ad methods of analysis. J Periodontol. 48 Supp 1:S13–20. DOI: 10.1902/jop.1977.48.1.13. PMID: 264535. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0017326741&origin=inward.
25. Nachnani S, Clark GT. 1997; Halitosis: a breath of fresh air. Clin Infect Dis. 25 Suppl 2:S218–219. DOI: 10.1086/516242. PMID: 9310683. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0030865348&origin=inward.
Article
26. Jolkovsky D, Waki M. Y., Newman M. G., Otomo-Corgel J., Madison M., Flemming T. F., Nachnani S., Nowzari H.. 1990; Clinical and microbiological effects of subgingival and gingival marginal irrigation with chlorhexidine gluconate. J Periodontol. 61 Supp 11:S663–669. DOI: 10.1902/jop.1990.61.11.663. PMID: 2254831. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0025054389&origin=inward.
Article
27. Flemmig T. F., Funkenhauser B., Epp Z., Newman M. G., Kornman K. S., Haubitz I., et al. 1995; Adjunctive supragingival irrigation with acetylsalicyclic acid in periodontal supportive therapy. J Clin Periodontol. 22:427–433. DOI: 10.1111/j.1600-051X.1995.tb00173.x. PMID: 7560220. PMID: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0029318561&origin=inward.
Article
Full Text Links
  • JKAOH
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr