Ultrasonography.  2022 Apr;41(2):307-316. 10.14366/usg.21081.

Improving the quality of breast ultrasound examination performed by inexperienced ultrasound doctors with synchronous tele-ultrasound: a prospective, parallel controlled trial

Affiliations
  • 1Center of Minimally Invasive Treatment for Tumor, Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, School of Medicine, Tongji University, Shanghai, China
  • 2Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University, Shanghai, China
  • 3Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Shanghai, China
  • 4National Clinical Research Center for Interventional Medicine, Shanghai, China
  • 5Department of Ultrasound, Karamay Center Hospital, Karamay, China
  • 6Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China

Abstract

Purpose
This prospective study explored the value of synchronous tele-ultrasound (US) to aid doctors inexperienced in US with breast US examinations.
Methods
In total, 99 patients were enrolled. Two trainee doctors who were inexperienced in US (trainee A [TA] and trainee B [TB]) and one doctor who was an expert in US completed the US examinations sequentially. TA completed the US examinations independently, while TB was instructed by the expert using synchronous tele-US. Subsequently, the expert performed on-site US examinations in person. Separately, they selected the most clinically significant nodule as the target nodule. Consistency with the expert and image quality were compared between TA and TB to evaluate tele-US. Furthermore, TB and the patients evaluated tele-US through questionnaires.
Results
TB demonstrated higher consistency with the expert in terms of target nodule selection than TA (93.3% vs. 63.3%, P<0.001). TB achieved good inter-observer agreement (ICC, >0.75) with the expert on five US features (5/9, 55.6%), while TA only did so for one (1/9, 11.1%) (P=0.046). TB’s image quality was higher than TA’s in gray value, time gain compensation, depth, color Doppler adjustment, and the visibility of key information (P=0.018, P<0.001, P<0.001, P=0.033, and P=0.006, respectively). The comprehensive assessment score was higher for TB than for TA (3.96±0.82 vs. 3.09±0.87, P<0.001). Tele-US was helpful in 69.7% of US examinations and had a training effect in 68.0%. Furthermore, 63.6% of patients accepted tele-US and 60.6% were willing to pay.
Conclusion
Tele-US can help doctors inexperienced in US to perform breast US examinations.

Keyword

Telemedicine; Tele-ultrasound; Breast ultrasound; Synchronous Tele-ultrasound