Clin Endosc.  2021 Sep;54(5):739-744. 10.5946/ce.2020.212.

Superior Specimen and Diagnostic Accuracy with Endoscopic Ultrasound-Guided Liver Biopsies Using 19-Gauge versus 22-Gauge Core Needles

Affiliations
  • 1Department of Gastroenterology, Methodist Dallas Medical Center, Dallas, TX, USA
  • 2Department of Pathology, Methodist Dallas Medical Center, Dallas, TX, USA
  • 3Department of Internal Medicine, Methodist Dallas Medical Center, Dallas, TX, USA
  • 4Methodist Health System Clinical Research Institute, Methodist Dallas Medical Center, Dallas, TX, USA
  • 5Digestive Health Associates of Texas, Dallas, TX, USA

Abstract

Background/Aims
Endoscopic ultrasound-guided liver biopsy (EUS-LB) is an effective and safe method of procuring liver tissue. The aims of this study were to assess and compare the outcomes and tissue adequacy of a single-pass, single-actuation, wet suction technique between 19 G and 22 G needles in patients undergoing EUS-LB.
Methods
We performed a prospective case series study of 20 patients undergoing EUS-LB at a single center between September 2017 and April 2020. The primary objective was to evaluate differences in sample adequacy via a single actuation wet suction technique between a 19 G core needle and a 22 G core needle. Adequacy was gauged by cumulative core biopsy length and the number of portal tracts visualized.
Results
The 19 G needle provided a longer core length (2.5 cm vs. 1.2 cm, p<0.0001), more complete portal tracts (5.8 vs. 1.7, p<0.0001), more total tracts (8.8 vs. 3, p<0.0001), and a longer, intact, fragment length (0.75 cm vs. 0.32 cm, p<0.0006). The 19 G needle was superior in providing adequate (60% vs. 5%, p<0.001) and diagnostic pathologic samples (85% vs. 10%, p<0.001).
Conclusions
A single-pass, single-actuation, wet suction technique using a 19 G needle is superior to that using a 22 G needle for tissue acquisition and sample adequacy in EUS-LB.

Keyword

19 G FNB; Endoscopic ultrasound-guided liver biopsy; Liver biopsy

Figure

  • Fig. 1. Endoscopic ultrasound-guided liver biopsy core sampling, 19 gauge fine-needle aspiration needle.


Reference

1. Schulman AR, Thompson CC, Odze R, Chan WW, Ryou M. Optimizing EUS-guided liver biopsy sampling: comprehensive assessment of needle types and tissue acquisition techniques. Gastrointest Endosc. 2017; 85:419–426.
Article
2. Pineda JJ, Diehl DL, Miao CL, et al. EUS-guided liver biopsy provides diagnostic samples comparable with those via the percutaneous or transjugular route. Gastrointest Endosc. 2016; 83:360–365.
3. Diehl DL, Johal AS, Khara HS, et al. Endoscopic ultrasound-guided liver biopsy: a multicenter experience. Endosc Int Open. 2015; 3:E210–E215.
Article
4. Parekh PJ, Majithia R, Diehl DL, Baron TH. Endoscopic ultrasound-guided liver biopsy. Endosc Ultrasound. 2015; 4:85–91.
Article
5. Mohan BP, Shakhatreh M, Garg R, Ponnada S, Adler DG. Efficacy and safety of EUS-guided liver biopsy: a systematic review and meta-analysis. Gastrointest Endosc. 2019; 89:238–246.e3.
Article
6. Bazerbachi F, Vargas EJ, Matar R, et al. EUS-guided core liver biopsy sampling using a 22-gauge fork-tip needle: a prospective blinded trial for histologic and lipidomic evaluation in nonalcoholic fatty liver disease. Gastrointest Endosc. 2019; 90:926–932.
7. Hasan MK, Kadkhodayan K, Idrisov E, et al. Endoscopic ultrasound-guided liver biopsy using a 22-G fine-needle biopsy needle: a prospective study. Endoscopy. 2019; 51:818–824.
8. Ching-Companioni RA, Diehl DL, Johal AS, Confer BD, Khara HS. 19G aspiration needle versus 19G core biopsy needle for endoscopic ultrasound-guided liver biopsy: a prospective randomized trial. Endoscopy. 2019; 51:1059–1065.
Article
9. Nieto J, Khaleel H, Challita Y, et al. EUS-guided fine-needle core liver biopsy sampling using a novel 19-gauge needle with modified 1-pass, 1 actuation wet suction technique. Gastrointest Endosc. 2018; 87:469–475.
10. Rockey DC, Caldwell SH, Goodman ZD, Nelson RC, Smith AD. Liver biopsy. Hepatology. 2009; 49:1017–1044.
Article
11. Caldwell S. Liver biopsy: the reports of its demise are greatly exaggerated. Clin Transl Gastroenterol. 2016; 7:e171.
Article
12. Bravo AA, Sheth SG, Chopra S. Liver biopsy. N Engl J Med. 2001; 344:495–500.
Article
13. Stavropoulos SN, Im GY, Jlayer Z, et al. High yield of same-session EUS-guided liver biopsy by 19-gauge FNA needle in patients undergoing EUS to exclude biliary obstruction. Gastrointest Endosc. 2012; 75:310–318.
Article
14. Shuja A, Alkhasawneh A, Fialho A, et al. Comparison of EUS-guided versus percutaneous and transjugular approaches for the performance of liver biopsies. Dig Liver Dis. 2019; 51:826–830.
Article
15. Mok SR, Diehl DL, Johal AS, et al. 19 versus 22 gauge fine-needle biopsy for endoscopic ultrasound guided liver biopsy (EUS-LB): a prospective randomized trial. Gastrointest Endosc. 2017; 85(5 Suppl):AB473–AB474.
16. Bhat I, Malvar G, Calmet F, et al. EUS-guided liver biopsy using 22G FNB vs. 19G FNB needles: a prospective comparison of core specimen size and diagnostic adequacy. Gastrointest Endosc. 2019; 89(6 Suppl):AB293.
Full Text Links
  • CE
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr