1. Proffit WR, Fields HW, Larson BE, Sarver DM. 2019. Contemporary orthodontics. Elsevier;Philadelphia:
2. Antoszewska-Smith J, Sarul M, Łyczek J, Konopka T, Kawala B. 2017; Effectiveness of orthodontic miniscrew implants in anchorage reinforcement during en-masse retraction: a systematic review and meta-analysis. Am J Orthod Dentofacial Orthop. 151:440–55. DOI:
10.1016/j.ajodo.2016.08.029. PMID:
28257728.
Article
3. Papadopoulos MA, Tarawneh F. 2007; The use of miniscrew implants for temporary skeletal anchorage in orthodontics: a comprehensive review. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 103:e6–15. DOI:
10.1016/j.tripleo.2006.11.022. PMID:
17317235.
Article
5. Papadopoulos MA, Papageorgiou SN, Zogakis IP. 2011; Clinical effectiveness of orthodontic miniscrew implants: a meta-analysis. J Dent Res. 90:969–76. DOI:
10.1177/0022034511409236. PMID:
21593250.
Article
6. Lin L, Ahn HW, Kim SJ, Moon SC, Kim SH, Nelson G. 2015; Tooth-borne vs bone-borne rapid maxillary expanders in late adolescence. Angle Orthod. 85:253–62. DOI:
10.2319/030514-156.1. PMID:
25490552.
Article
7. Papageorgiou SN, Zogakis IP, Papadopoulos MA. 2012; Failure rates and associated risk factors of orthodontic miniscrew implants: a meta-analysis. Am J Orthod Dentofacial Orthop. 142:577–95.e7. DOI:
10.1016/j.ajodo.2012.05.016. PMID:
23116500.
Article
8. Higgins JPT, Green S. 2011. Cochrane handbook for systematic reviews of interventions version 5.1.0 [updated March 2011]. The Cochrane Collaboration;London:
9. Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gøtzsche PC, Ioannidis JP, et al. 2009; The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. J Clin Epidemiol. 62:e1–34. DOI:
10.1016/j.jclinepi.2009.06.006. PMID:
19631507.
Article
10. Wells GA, Shea B, O'Connell D, Peterson J, Welch V, Losos M, et al. 2013. The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomised studies in meta-analyses. University of Ottawa;Ottawa:
11. Alharbi F, Almuzian M, Bearn D. 2018; Miniscrews failure rate in orthodontics: systematic review and meta-analysis. Eur J Orthod. 40:519–30. DOI:
10.1093/ejo/cjx093. PMID:
29315365.
Article
12. Reynders R, Ronchi L, Bipat S. 2009; Mini-implants in orthodontics: a systematic review of the literature. Am J Orthod Dentofacial Orthop. 135:564.e1–19. discussion 564–5. DOI:
10.1016/j.ajodo.2008.09.026. PMID:
19409331.
Article
14. Al-Kharsa SS, Masoud AI. 2017; A proposed method for covering a mini-screw head while maintaining space for ligation. Int J Orthod Milwaukee. 28:65–6. PMID:
29990405.
16. Er K, Bayram M, Taşdemir T. 2011; Root canal treatment of a periradicular lesion caused by unintentional root damage after orthodontic miniscrew placement: a case report. Int Endod J. 44:1170–5. DOI:
10.1111/j.1365-2591.2011.01933.x. PMID:
21851367.
Article
17. Ghislanzoni LH, Berardinelli F, Ludwig B, Lucchese A. 2016; Considerations involved in placing miniscrews near the nasopalatine bundle. J Clin Orthod. 50:321–8. PMID:
27323275.
18. Hwang YC, Hwang HS. 2011; Surgical repair of root perforation caused by an orthodontic miniscrew implant. Am J Orthod Dentofacial Orthop. 139:407–11. DOI:
10.1016/j.ajodo.2008.11.032. PMID:
21392697.
Article
19. Lee JY, Kim PS, Choi C, Kim KB. 2016; Root repair and regeneration after miniscrew root damage. J World Fed Orthod. 5:70–8. DOI:
10.1016/j.ejwf.2016.02.005.
Article
20. Marquezan M, de Freitas AO, Nojima LI. 2012; Miniscrew covering: an alternative to prevent traumatic lesions. Am J Orthod Dentofacial Orthop. 141:242–4. DOI:
10.1016/j.ajodo.2010.05.027. PMID:
22284292.
Article
22. Qin YJ, Zhang GD, Zhang Y, Ping YF, Zhao CY. 2016; Natural reversal of tooth discoloration and pulpal response to testing following removal of a miniscrew implant for orthodontic anchorage: a case report. Int Endod J. 49:402–9. DOI:
10.1111/iej.12459. PMID:
25877019.
Article
23. Lim G, Kim KD, Park W, Jung BY, Pang NS. 2013; Endodontic and surgical treatment of root damage caused by orthodontic miniscrew placement. J Endod. 39:1073–7. DOI:
10.1016/j.joen.2013.04.037. PMID:
23880281.
Article
24. Chen CM, Chang CS, Tseng YC, Hsu KR, Lee KT, Lee HE. 2011; The perception of pain following interdental microimplant treatment for skeletal anchorage: a retrospective study. Odontology. 99:88–91. DOI:
10.1007/s10266-010-0152-1. PMID:
21271332.
Article
25. Fäh R, Schätzle M. 2014; Complications and adverse patient reactions associated with the surgical insertion and removal of palatal implants: a retrospective study. Clin Oral Implants Res. 25:653–8. DOI:
10.1111/clr.12152. PMID:
23551587.
Article
26. Gurdan Z, Szalma J. 2018; Evaluation of the success and complication rates of self-drilling orthodontic mini-implants. Niger J Clin Pract. 21:546–52. DOI:
10.4103/njcp.njcp_105_17. PMID:
29735852.
Article
27. Hourfar J, Bister D, Lisson JA, Ludwig B. 2017; Incidence of pulp sensibility loss of anterior teeth after paramedian insertion of orthodontic mini-implants in the anterior maxilla. Head Face Med. 13:1. DOI:
10.1186/s13005-016-0134-9. PMID:
28061791. PMCID:
PMC5217250.
Article
28. Jia X, Chen X, Huang X. 2018; Influence of orthodontic mini-implant penetration of the maxillary sinus in the infrazygomatic crest region. Am J Orthod Dentofacial Orthop. 153:656–61. DOI:
10.1016/j.ajodo.2017.08.021. PMID:
29706213.
Article
29. Jung SA, Choi YJ, Lee DW, Kim KH, Chung CJ. 2015; Cross-sectional evaluation of the prevalence and factors associated with soft tissue scarring after the removal of miniscrews. Angle Orthod. 85:420–6. DOI:
10.2319/101813-772.1. PMID:
25153264.
Article
30. Takaki T, Tamura N, Yamamoto M, Takano N, Shibahara T, Yasumura T, et al. 2010; Clinical study of temporary anchorage devices for orthodontic treatment--stability of micro/mini-screws and mini-plates: experience with 455 cases. Bull Tokyo Dent Coll. 51:151–63. DOI:
10.2209/tdcpublication.51.151. PMID:
20877162.
31. Ziebura T, Flieger S, Wiechmann D. 2012; Mini-implants in the palatal slope--a retrospective analysis of implant survival and tissue reaction. Head Face Med. 8:32. DOI:
10.1186/1746-160X-8-32. PMID:
23157849. PMCID:
PMC3546431.
Article
32. Motoyoshi M, Sanuki-Suzuki R, Uchida Y, Saiki A, Shimizu N. 2015; Maxillary sinus perforation by orthodontic anchor screws. J Oral Sci. 57:95–100. DOI:
10.2334/josnusd.57.95. PMID:
26062857.
Article
33. Shinohara A, Motoyoshi M, Uchida Y, Shimizu N. 2013; Root proximity and inclination of orthodontic mini-implants after placement: cone-beam computed tomography evaluation. Am J Orthod Dentofacial Orthop. 144:50–6. DOI:
10.1016/j.ajodo.2013.02.021. PMID:
23810045.
Article
34. Fabbroni G, Aabed S, Mizen K, Starr DG. 2004; Transalveolar screws and the incidence of dental damage: a prospective study. Int J Oral Maxillofac Surg. 33:442–6. DOI:
10.1016/j.ijom.2003.10.014. PMID:
15183406.
Article
35. Wang Z, Zhang D, Liu Y, Zhao Z. 2010; Buccal mucosal lesions caused by the interradicular miniscrew: a preliminary report. Int J Oral Maxillofac Implants. 25:1183–8. PMID:
21197496.
36. Gracco A, Tracey S, Baciliero U. 2010; Miniscrew insertion and the maxillary sinus: an endoscopic evaluation. J Clin Orthod. 44:439–43. PMID:
21038797.
37. Nucera R, Bellocchio AM, Oteri G, Farah AJ, Rosalia L, Giancarlo C, et al. 2019; Bone and cortical bone characteristics of mandibular retromolar trigone and anterior ramus region for miniscrew insertion in adults. Am J Orthod Dentofacial Orthop. 155:330–8. DOI:
10.1016/j.ajodo.2018.04.025. PMID:
30826035.
Article
38. Nucera R, Lo Giudice A, Bellocchio AM, Spinuzza P, Caprioglio A, Perillo L, et al. 2017; Bone and cortical bone thickness of mandibular buccal shelf for mini-screw insertion in adults. Angle Orthod. 87:745–51. DOI:
10.2319/011117-34.1. PMID:
28598220.
Article
40. Kuroda S, Yamada K, Deguchi T, Hashimoto T, Kyung HM, Takano-Yamamoto T. 2007; Root proximity is a major factor for screw failure in orthodontic anchorage. Am J Orthod Dentofacial Orthop. 131(4 Suppl):S68–73. DOI:
10.1016/j.ajodo.2006.06.017. PMID:
17448389.
Article
42. Renjen R, Maganzini AL, Rohrer MD, Prasad HS, Kraut RA. 2009; Root and pulp response after intentional injury from miniscrew placement. Am J Orthod Dentofacial Orthop. 136:708–14. DOI:
10.1016/j.ajodo.2007.12.031. PMID:
19892289.
Article
43. Carano A, Velo S, Leone P, Siciliani G. 2005; Clinical applications of the Miniscrew Anchorage System. J Clin Orthod. 39:9–24. quiz 29–30. PMID:
29130922.
44. Suzuki EY, Buranastidporn B. 2005; An adjustable surgical guide for miniscrew placement. J Clin Orthod. 39:588–90. PMID:
16244426.
45. Poggio PM, Incorvati C, Velo S, Carano A. 2006; "Safe zones": a guide for miniscrew positioning in the maxillary and mandibular arch. Angle Orthod. 76:191–7.
46. Carano A, Velo S, Incorvati C, Poggio P. 2004; Clinical applications of the Mini-Screw-Anchorage-System (M.A.S.) in the maxillary alveolar bone. Prog Orthod. 5:212–35. PMID:
15546013.
47. Reicheneder C, Rottner K, Bokan I, Mai R, Lauer G, Richter G, et al. 2008; Mechanical loading of orthodontic miniscrews - significance and problems: an experimental study. Biomed Tech (Berl). 53:242–5. DOI:
10.1515/BMT.2008.038. PMID:
18840065.
Article
48. Kyung HM, Park HS, Bae SM, Sung JH, Kim IB. 2003; Development of orthodontic micro-implants for intraoral anchorage. J Clin Orthod. 37:321–8. quiz 314PMID:
12866214.
49. Smith A, Hosein YK, Dunning CE, Tassi A. 2015; Fracture resistance of commonly used self-drilling orthodontic mini-implants. Angle Orthod. 85:26–32. DOI:
10.2319/112213-860.1. PMID:
24869900.
Article
50. Chen Y, Kyung HM, Gao L, Yu WJ, Bae EJ, Kim SM. 2010; Mechanical properties of self-drilling orthodontic micro-implants with different diameters. Angle Orthod. 80:821–7. DOI:
10.2319/103009-607.1. PMID:
20578851.
Article
51. Lim SA, Cha JY, Hwang CJ. 2008; Insertion torque of orthodontic miniscrews according to changes in shape, diameter and length. Angle Orthod. 78:234–40. DOI:
10.2319/121206-507.1. PMID:
18251617.
Article
52. Wilmes B, Rademacher C, Olthoff G, Drescher D. 2006; Parameters affecting primary stability of orthodontic mini-implants. J Orofac Orthop. 67:162–74. DOI:
10.1007/s00056-006-0611-z. PMID:
16736117.
Article
53. Ludwig B, Glasl B, Bowman SJ, Wilmes B, Kinzinger GS, Lisson JA. 2011; Anatomical guidelines for miniscrew insertion: palatal sites. J Clin Orthod. 45:433–41. quiz 467PMID:
22094724.
54. Winsauer H, Vlachojannis C, Bumann A, Vlachojannis J, Chrubasik S. 2014; Paramedian vertical palatal bone height for mini-implant insertion: a systematic review. Eur J Orthod. 36:541–9. DOI:
10.1093/ejo/cjs068. PMID:
23221896.
Article
55. Lo Giudice A, Quinzi V, Ronsivalle V, Martina S, Bennici O, Isola G. 2020; Description of a digital work-flow for CBCT-guided construction of micro-implant supported maxillary skeletal expander. Materials (Basel). 13:1815. DOI:
10.3390/ma13081815. PMID:
32290597. PMCID:
PMC7215674.
Article
56. Yoon S, Lee DY, Jung SK. 2019; Influence of changing various parameters in miniscrew-assisted rapid palatal expansion: a three-dimensional finite element analysis. Korean J Orthod. 49:150–60. DOI:
10.4041/kjod.2019.49.3.150. PMID:
31149605. PMCID:
PMC6533180.
Article
57. Hourfar J, Ludwig B, Bister D, Braun A, Kanavakis G. 2015; The most distal palatal ruga for placement of orthodontic mini-implants. Eur J Orthod. 37:373–8. DOI:
10.1093/ejo/cju056. PMID:
25336563.
Article
58. Liou EJ, Chen PH, Wang YC, Lin JC. 2007; A computed tomographic image study on the thickness of the infrazygomatic crest of the maxilla and its clinical implications for miniscrew insertion. Am J Orthod Dentofacial Orthop. 131:352–6. DOI:
10.1016/j.ajodo.2005.04.044. PMID:
17346590.
Article