J Neurogastroenterol Motil.  2021 Apr;27(2):198-204. 10.5056/jnm20125.

Simultaneous Evaluation of Laryngopharyngeal Reflux and Swallowing Function Using Hypopharyngeal Multichannel Intraluminal Impedance Measurements in Neurologically Impaired Patients

Affiliations
  • 1Department of Pediatric Surgery, Kurume University School of Medicine, Fukuoka, Japan
  • 2Department of Division of Medical Safety Management, Kurume University School of Medicine, Fukuoka, Japan

Abstract

Background/Aims
This study aims to evaluate the presence of laryngopharyngeal reflux (LPR) and to investigate the use of hypopharyngeal baseline impedance (BI) for assessing swallowing dysfunction and gastroesophageal reflux disease (GERD) using hypopharyngeal multichannel intraluminal impedance and pH (HMII-pH) monitoring in neurologically impaired patients (NIPs).
Methods
The study population in this retrospective study comprised 20 NIPs (mean age, 36.1 ± 15.0 years; age range, 13-64 years) who underwent multichannel intraluminal impedance and pH (MII-pH), HMII-pH, and laryngoscopy using the Hyodo scoring method from December 2016 to April 2019. The MII-pH and HMM-pH parameters were compared in the NIPs, whereas hypopharyngeal BI values were compared between NIPs with ≥ 5 and < 5 in Hyodo scores. Correlations between the hypopharyngeal BI values and the Hyodo score were analyzed using Spearman’s correlation coefficient. A receiver operator characteristic curve was created to determine the optimum cut-off of hypopharyngeal BI value to discriminate SD.
Results
Three NIPs were diagnosed with pathological LPR and GERD by the HMII-pH monitoring. No significant differences in parameters were observed between MII-pH and HMII-pH monitoring. The correlation analysis demonstrated a significant negative correlation between the hypopharyngeal BI values and Hyodo scores. The optimal cutoff value for hypopharyngeal BI was 1552 Ω.
Conclusions
This study demonstrated the usefulness of HMII-pH monitoring in identifying NIP with pathological LPR. Considering the difficulties in performing examinations in NIPs, HMII-pH monitoring may be a potentially useful technique for the simultaneous evaluation of swallowing dysfunction, LPR, and GERD in NIP.

Keyword

Baseline impedance; Dysphagia; Gastroesophageal reflux disease; Laryngopharyngeal reflux; Multichannel intraluminal impedance measurement